  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-07-29",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "status": "Terminated",
      "city": "New Brunswick",
      "state": "NJ",
      "country": "United States",
      "classification": "Class I",
      "openfda": {},
      "product_type": "Drugs",
      "event_id": "91381",
      "recalling_firm": "Spectrum Laboratory Products, Inc.",
      "address_1": "755, 769 And 777 Jersey Ave",
      "address_2": "N/A",
      "postal_code": "08901-3605",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "Letter",
      "distribution_pattern": "Nationwide in the USA, Puerto Rico and Canada",
      "recall_number": "D-0180-2023",
      "product_description": "Epinephrine (L-Adrenaline), USP, CAS 51-43-4, Packaged in amber glass bottles in a vacuum sealed pouch as (a)100 G; (b)1 G, (c) 25 G, (d) 5 G; Rx only. Repackaged by Spectrum Chemical Mfg. Corp. Gardena, CA 90248; New Brunswick, NJ 08901.",
      "product_quantity": "7 x 100G; 17 x  1G; 6 x 25G; 20 x 5G",
      "reason_for_recall": "Discoloration: Product complaints of the repackaged Epinephrine API being discolored which could result in less effective product",
      "recall_initiation_date": "20221219",
      "center_classification_date": "20230125",
      "termination_date": "20250819",
      "report_date": "20230201",
      "code_info": "Lot # (a) (b) (c) (d) lot 2KL0353, EXP 30-Sep-2023; 2KF0151, EXP 31-Mar-2023",
      "more_code_info": ""
    }
  ]
}