  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-11-02",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 17
    }
  },
  "results": [
    {
      "has_donation_id_number": "false",
      "mri_safety": "Labeling does not contain MRI Safety Information",
      "record_status": "Published",
      "is_labeled_as_nrl": "false",
      "is_rx": "true",
      "commercial_distribution_status": "In Commercial Distribution",
      "device_description": "Aptima® BV assay, 250 test, box 1 of 2 (2°C to 8°C box). The Aptima® BV assay is an in vitro nucleic acid amplification test that utilizes real time transcription-mediated amplification (TMA®) for detection and quantitation of ribosomal RNA from bacteria associated with bacterial vaginosis (BV), including Lactobacillus (L. gasseri, L. crispatus, and L. jensenii), Gardnerella vaginalis, and Atopobium vaginae.",
      "public_device_record_key": "c03ffd9e-8dc7-4297-9d06-8e2ad4e9ee09",
      "has_serial_number": "false",
      "storage": [
        {
          "type": "Storage Environment Temperature",
          "high": {
            "unit": "Degrees Celsius",
            "value": "8"
          },
          "low": {
            "unit": "Degrees Celsius",
            "value": "2"
          }
        }
      ],
      "public_version_date": "2025-05-09",
      "sterilization": {
        "is_sterile": "false",
        "is_sterilization_prior_use": "false"
      },
      "is_direct_marking_exempt": "true",
      "public_version_number": "2",
      "labeler_duns_number": "050579217",
      "is_labeled_as_no_nrl": "false",
      "identifiers": [
        {
          "id": "15420045517059",
          "type": "Primary",
          "issuing_agency": "GS1"
        }
      ],
      "is_single_use": "false",
      "is_otc": "false",
      "version_or_model_number": "KIT, BOX 1, REFRIGERATED, ABV, 250T, IVD",
      "has_manufacturing_date": "false",
      "brand_name": "Aptima®",
      "is_combination_product": "false",
      "is_kit": "false",
      "product_codes": [
        {
          "code": "PQA",
          "name": "Vaginitis and bacterial vaginosis nucleic acid detection system",
          "openfda": {
            "device_name": "Vaginitis And Bacterial Vaginosis Nucleic Acid Detection System",
            "medical_specialty_description": "Microbiology",
            "regulation_number": "866.3975",
            "device_class": "2"
          }
        },
        {
          "code": "PMN",
          "name": "Assayed external control material for microbiology nucleic acid amplification (NAT) assays",
          "openfda": {
            "device_name": "Assayed External Control Material For Microbiology Nucleic Acid Amplification (Nat) Assays",
            "medical_specialty_description": "Microbiology",
            "regulation_number": "866.3920",
            "device_class": "2"
          }
        },
        {
          "code": "NSU",
          "name": "Instrumentation for clinical multiplex test systems",
          "openfda": {
            "device_name": "Instrumentation For Clinical Multiplex Test Systems",
            "medical_specialty_description": "Clinical Chemistry",
            "regulation_number": "862.2570",
            "device_class": "2"
          }
        }
      ],
      "premarket_submissions": [
        {
          "submission_number": "K243345",
          "supplement_number": "000"
        }
      ],
      "device_count_in_base_package": "1",
      "is_pm_exempt": "false",
      "has_lot_or_batch_number": "true",
      "customer_contacts": [
        {
          "phone": "+1(800)442-9892",
          "email": "CustomerSupport@hologic.com"
        }
      ],
      "catalog_number": "ASY-16712",
      "company_name": "Hologic, Inc.",
      "public_version_status": "Update",
      "has_expiration_date": "true",
      "is_hct_p": "false",
      "gmdn_terms": [
        {
          "code": "48210",
          "name": "Multiple vaginitis/vaginosis-associated pathogen nucleic acid IVD, control",
          "definition": "A material which is used to verify the performance of an assay intended to be used for the qualitative and/or quantitative detection of nucleic acid from multiple types of pathogens associated with vaginitis and/or vaginosis in a clinical specimen. Pathogens intended to be detected may include Candida or other yeast species, Gardnerella vaginalis and/or Trichomonas vaginalis.",
          "implantable": "false",
          "code_status": "Active"
        }
      ],
      "publish_date": "2024-12-19"
    }
  ]
}