{
  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-11-02",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 5994
    }
  },
  "results": [
    {
      "has_donation_id_number": "false",
      "mri_safety": "Labeling does not contain MRI Safety Information",
      "record_status": "Published",
      "is_labeled_as_nrl": "false",
      "is_rx": "true",
      "commercial_distribution_status": "In Commercial Distribution",
      "public_device_record_key": "055b04f7-79cd-4a8c-914d-a30dff6f90ab",
      "has_serial_number": "false",
      "public_version_date": "2025-05-30",
      "sterilization": {
        "is_sterile": "true",
        "is_sterilization_prior_use": "false"
      },
      "is_direct_marking_exempt": "false",
      "public_version_number": "8",
      "labeler_duns_number": "129278169",
      "is_labeled_as_no_nrl": "false",
      "identifiers": [
        {
          "id": "00887868059773",
          "type": "Primary",
          "issuing_agency": "GS1"
        }
      ],
      "is_single_use": "true",
      "is_otc": "false",
      "version_or_model_number": "8555-40-030",
      "has_manufacturing_date": "false",
      "brand_name": "CANCELLOUS LAG SCREW",
      "is_combination_product": "false",
      "is_kit": "false",
      "product_codes": [
        {
          "code": "HTN",
          "name": "WASHER, BOLT NUT",
          "openfda": {
            "device_name": "Washer, Bolt Nut",
            "medical_specialty_description": "Orthopedic",
            "regulation_number": "888.3030",
            "device_class": "2"
          }
        },
        {
          "code": "JDW",
          "name": "PIN, FIXATION, THREADED",
          "openfda": {
            "device_name": "Pin, Fixation, Threaded",
            "medical_specialty_description": "Orthopedic",
            "regulation_number": "888.3040",
            "device_class": "2"
          }
        },
        {
          "code": "KTT",
          "name": "APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT",
          "openfda": {
            "device_name": "Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component",
            "medical_specialty_description": "Orthopedic",
            "regulation_number": "888.3030",
            "device_class": "2"
          }
        },
        {
          "code": "HSB",
          "name": "ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES",
          "openfda": {
            "device_name": "Rod, Fixation, Intramedullary And Accessories",
            "medical_specialty_description": "Orthopedic",
            "regulation_number": "888.3020",
            "device_class": "2"
          }
        },
        {
          "code": "HTY",
          "name": "PIN, FIXATION, SMOOTH",
          "openfda": {
            "device_name": "Pin, Fixation, Smooth",
            "medical_specialty_description": "Orthopedic",
            "regulation_number": "888.3040",
            "device_class": "2"
          }
        },
        {
          "code": "HWC",
          "name": "Screw, fixation, bone",
          "openfda": {
            "device_name": "Screw, Fixation, Bone",
            "medical_specialty_description": "Orthopedic",
            "regulation_number": "888.3040",
            "device_class": "2"
          }
        },
        {
          "code": "LXT",
          "name": "APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT, METAL COMPOSITE",
          "openfda": {
            "device_name": "Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component, Metal Composite",
            "medical_specialty_description": "Orthopedic",
            "regulation_number": "888.3030",
            "device_class": "2"
          }
        },
        {
          "code": "HRS",
          "name": "PLATE, FIXATION, BONE",
          "openfda": {
            "device_name": "Plate, Fixation, Bone",
            "medical_specialty_description": "Orthopedic",
            "regulation_number": "888.3030",
            "device_class": "2"
          }
        }
      ],
      "device_count_in_base_package": "1",
      "is_pm_exempt": "false",
      "has_lot_or_batch_number": "true",
      "customer_contacts": [
        {
          "phone": "+1(800)348-9500",
          "email": "customerservice@zimmerbiomet.com"
        }
      ],
      "catalog_number": "855540030",
      "company_name": "Biomet Orthopedics, LLC",
      "public_version_status": "Update",
      "has_expiration_date": "true",
      "is_hct_p": "false",
      "gmdn_terms": [
        {
          "code": "46646",
          "name": "Orthopaedic bone screw, non-bioabsorbable, sterile",
          "definition": "A small, sterile, threaded rod with a slotted head typically used for internal orthopaedic fracture fixation by being screwed into bone to hold plates or nails to bone or to provide direct interfragmentary stabilization of bone, or it may fasten soft tissue to bone; it is made of a material that cannot be chemically degraded or absorbed via natural body processes (includes implant grade metal such as surgical steel, titanium alloy, or carbon fibre). There are a number of kinds available: cortical, cancellous, malleolar, scaphoid, partially-threaded and fully-threaded, self-tapping, and cannulated. A \"lag screw\" can be any of these used to obtain compression across bone fragments.",
          "implantable": "false",
          "code_status": "Obsolete"
        }
      ],
      "publish_date": "2015-10-24",
      "device_sizes": [
        {
          "type": "Device Size Text, specify",
          "text": "4.0MM X 30MM"
        }
      ]
    }
  ]
}