  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-11-02",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 161
    }
  },
  "results": [
    {
      "has_donation_id_number": "false",
      "mri_safety": "Labeling does not contain MRI Safety Information",
      "record_status": "Published",
      "is_labeled_as_nrl": "false",
      "is_rx": "true",
      "commercial_distribution_status": "In Commercial Distribution",
      "device_description": "Device for ultrasound therapy",
      "public_device_record_key": "6ed6ad53-c132-46d0-a0cf-2ae202a9b509",
      "has_serial_number": "true",
      "storage": [
        {
          "type": "Handling Environment Atmospheric Pressure",
          "high": {
            "unit": "KiloPascal",
            "value": "106"
          },
          "low": {
            "unit": "KiloPascal",
            "value": "80"
          }
        },
        {
          "type": "Handling Environment Humidity",
          "high": {
            "unit": "Percent (%) Relative Humidity",
            "value": "90"
          },
          "low": {
            "unit": "Percent (%) Relative Humidity",
            "value": "10"
          }
        },
        {
          "type": "Handling Environment Temperature",
          "high": {
            "unit": "Degrees Celsius",
            "value": "40"
          },
          "low": {
            "unit": "Degrees Celsius",
            "value": "10"
          }
        },
        {
          "type": "Storage Environment Atmospheric Pressure",
          "high": {
            "unit": "KiloPascal",
            "value": "106"
          },
          "low": {
            "unit": "KiloPascal",
            "value": "50"
          }
        },
        {
          "type": "Storage Environment Humidity",
          "high": {
            "unit": "Percent (%) Relative Humidity",
            "value": "90"
          },
          "low": {
            "unit": "Percent (%) Relative Humidity",
            "value": "10"
          }
        },
        {
          "type": "Storage Environment Temperature",
          "high": {
            "unit": "Degrees Celsius",
            "value": "70"
          },
          "low": {
            "unit": "Degrees Celsius",
            "value": "-20"
          }
        }
      ],
      "public_version_date": "2025-02-19",
      "sterilization": {
        "is_sterile": "false",
        "is_sterilization_prior_use": "false"
      },
      "is_direct_marking_exempt": "false",
      "public_version_number": "1",
      "labeler_duns_number": "414024224",
      "is_labeled_as_no_nrl": "false",
      "identifiers": [
        {
          "id": "08720618311108",
          "type": "Primary",
          "issuing_agency": "GS1"
        }
      ],
      "is_single_use": "false",
      "is_otc": "false",
      "version_or_model_number": "1631951",
      "has_manufacturing_date": "true",
      "brand_name": "Sonopuls 190",
      "is_combination_product": "false",
      "is_kit": "false",
      "product_codes": [
        {
          "code": "IMI",
          "name": "Ultrasonic Diathermy For Use In Applying Therapeutic Deep Heat",
          "openfda": {
            "device_name": "Ultrasonic Diathermy For Use In Applying Therapeutic Deep Heat",
            "medical_specialty_description": "Physical Medicine",
            "regulation_number": "890.5300",
            "device_class": "2"
          }
        }
      ],
      "premarket_submissions": [
        {
          "submission_number": "K230472",
          "supplement_number": "000"
        }
      ],
      "device_count_in_base_package": "1",
      "is_pm_exempt": "false",
      "has_lot_or_batch_number": "false",
      "company_name": "Enraf-Nonius B.V.",
      "public_version_status": "New",
      "has_expiration_date": "false",
      "is_hct_p": "false",
      "gmdn_terms": [
        {
          "code": "11248",
          "name": "Physical therapy ultrasound system",
          "definition": "An assembly of devices designed to produce and deliver ultrasonic waves that penetrate tissues and produce both thermal and nonthermal (e.g., mechanical and cavitation) effects to treat pain (e.g., muscle, tendon, joint) and as an aid in the healing of soft-tissue injuries (e.g., ulcerations, bursitis). It typically consists of a radio-frequency (RF) generator (frequencies from one to three megahertz are typical), a cable that transmits the RF energy to the applicator, and an applicator including a piezoelectric transducer that applies the ultrasonic energy to the patient's tissues through the skin.",
          "implantable": "false",
          "code_status": "Active"
        }
      ],
      "publish_date": "2025-02-11"
    }
  ]
}