  "results": [
    {
      "has_donation_id_number": "false",
      "mri_safety": "Labeling does not contain MRI Safety Information",
      "record_status": "Published",
      "is_labeled_as_nrl": "false",
      "is_rx": "false",
      "commercial_distribution_status": "In Commercial Distribution",
      "device_description": "Tanner Scientific CLIA waived 13 Panel, AMP/BAR/BUP/BZO/COC/MDMA/MET/OPI300/MTD/OXY/PCP/TCA/THC",
      "public_device_record_key": "3937f387-3e9d-4c5f-8e27-a676864720a5",
      "has_serial_number": "false",
      "storage": [
        {
          "type": "Special Storage Condition, Specify",
          "special_conditions": "Keep away from direct sunlight, moisture, and heat"
        },
        {
          "type": "Special Storage Condition, Specify",
          "special_conditions": "Do Not Freeze"
        },
        {
          "type": "Handling Environment Temperature",
          "high": {
            "unit": "Degrees Fahrenheit",
            "value": "86"
          },
          "low": {
            "unit": "Degrees Fahrenheit",
            "value": "40"
          }
        }
      ],
      "public_version_date": "2022-12-20",
      "sterilization": {
        "is_sterile": "false",
        "is_sterilization_prior_use": "false"
      },
      "is_direct_marking_exempt": "false",
      "public_version_number": "8",
      "labeler_duns_number": "834472680",
      "is_labeled_as_no_nrl": "false",
      "identifiers": [
        {
          "id": "20850011007130",
          "type": "Package",
          "issuing_agency": "GS1",
          "unit_of_use_id": "10850011007133",
          "quantity_per_package": "4",
          "package_status": "In Commercial Distribution",
          "package_type": "Case"
        },
        {
          "id": "10850011007133",
          "type": "Package",
          "issuing_agency": "GS1",
          "unit_of_use_id": "00850011007136",
          "quantity_per_package": "25",
          "package_status": "In Commercial Distribution",
          "package_type": "Inner Pack"
        },
        {
          "id": "00850011007136",
          "type": "Primary",
          "issuing_agency": "GS1"
        }
      ],
      "is_single_use": "true",
      "is_otc": "false",
      "version_or_model_number": "TNR DOA13A",
      "has_manufacturing_date": "false",
      "brand_name": "Tanner Scientific®",
      "is_combination_product": "false",
      "is_kit": "false",
      "product_codes": [
        {
          "code": "LDJ",
          "name": "Enzyme Immunoassay, Cannabinoids",
          "openfda": {
            "device_name": "Enzyme Immunoassay, Cannabinoids",
            "medical_specialty_description": "Clinical Toxicology",
            "regulation_number": "862.3870",
            "device_class": "2"
          }
        },
        {
          "code": "LFG",
          "name": "Radioimmunoassay, Tricyclic Antidepressant Drugs",
          "openfda": {
            "device_name": "Radioimmunoassay, Tricyclic Antidepressant Drugs",
            "medical_specialty_description": "Clinical Toxicology",
            "regulation_number": "862.3910",
            "device_class": "2"
          }
        },
        {
          "code": "LCM",
          "name": "Enzyme Immunoassay, Phencyclidine",
          "openfda": {
            "device_name": "Enzyme Immunoassay, Phencyclidine",
            "medical_specialty_description": "Unknown",
            "regulation_number": "",
            "device_class": "U"
          }
        },
        {
          "code": "DJR",
          "name": "Enzyme Immunoassay, Methadone",
          "openfda": {
            "device_name": "Enzyme Immunoassay, Methadone",
            "medical_specialty_description": "Clinical Toxicology",
            "regulation_number": "862.3620",
            "device_class": "2"
          }
        },
        {
          "code": "DNK",
          "name": "Thin Layer Chromatography, Morphine",
          "openfda": {
            "device_name": "Thin Layer Chromatography, Morphine",
            "medical_specialty_description": "Clinical Toxicology",
            "regulation_number": "862.3640",
            "device_class": "2"
          }
        },
        {
          "code": "DJC",
          "name": "Thin Layer Chromatography, Methamphetamine",
          "openfda": {
            "device_name": "Thin Layer Chromatography, Methamphetamine",
            "medical_specialty_description": "Clinical Toxicology",
            "regulation_number": "862.3610",
            "device_class": "2"
          }
        },
        {
          "code": "DIO",
          "name": "Enzyme Immunoassay, Cocaine And Cocaine Metabolites",
          "openfda": {
            "device_name": "Enzyme Immunoassay, Cocaine And Cocaine Metabolites",
            "medical_specialty_description": "Clinical Toxicology",
            "regulation_number": "862.3250",
            "device_class": "2"
          }
        },
        {
          "code": "JXM",
          "name": "Enzyme Immunoassay, Benzodiazepine",
          "openfda": {
            "device_name": "Enzyme Immunoassay, Benzodiazepine",
            "medical_specialty_description": "Clinical Toxicology",
            "regulation_number": "862.3170",
            "device_class": "2"
          }
        },
        {
          "code": "DJG",
          "name": "Enzyme Immunoassay, Opiates",
          "openfda": {
            "device_name": "Enzyme Immunoassay, Opiates",
            "medical_specialty_description": "Clinical Toxicology",
            "regulation_number": "862.3650",
            "device_class": "2"
          }
        },
        {
          "code": "DIS",
          "name": "Enzyme Immunoassay, Barbiturate",
          "openfda": {
            "device_name": "Enzyme Immunoassay, Barbiturate",
            "medical_specialty_description": "Clinical Toxicology",
            "regulation_number": "862.3150",
            "device_class": "2"
          }
        },
        {
          "code": "DKZ",
          "name": "Enzyme Immunoassay, Amphetamine",
          "openfda": {
            "device_name": "Enzyme Immunoassay, Amphetamine",
            "medical_specialty_description": "Clinical Toxicology",
            "regulation_number": "862.3100",
            "device_class": "2"
          }
        }
      ],
      "premarket_submissions": [
        {
          "submission_number": "K153050",
          "supplement_number": "000"
        }
      ],
      "device_count_in_base_package": "1",
      "is_pm_exempt": "false",
      "has_lot_or_batch_number": "true",
      "customer_contacts": [
        {
          "phone": "8003312716",
          "email": "sherry.harris@mercedesmedical.com"
        }
      ],
      "catalog_number": "TNR DOA13A",
      "company_name": "MERCEDES MEDICAL, LLC",
      "public_version_status": "Update",
      "has_expiration_date": "true",
      "is_hct_p": "false",
      "gmdn_terms": [
        {
          "code": "30516",
          "name": "Amphetamine-specific IVD, kit, rapid ICT, clinical",
          "definition": "A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of a specific amphetamine in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing.",
          "implantable": "false",
          "code_status": "Active"
        },
        {
          "code": "30517",
          "name": "Barbiturate IVD, kit, rapid ICT, clinical",
          "definition": "A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of barbiturates in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing.",
          "implantable": "false",
          "code_status": "Active"
        },
        {
          "code": "42751",
          "name": "Buprenorphine IVD, kit, enzyme immunoassay (EIA)",
          "definition": "A collection of reagents and other associated materials intended to be used for the qualitative and/or quantitative detection of buprenorphine in a clinical specimen, using an enzyme immunoassay (EIA) method.",
          "implantable": "false",
          "code_status": "Active"
        },
        {
          "code": "30518",
          "name": "Benzodiazepine group IVD, kit, rapid ICT, clinical",
          "definition": "A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of benzodiazepine in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing.",
          "implantable": "false",
          "code_status": "Active"
        },
        {
          "code": "30520",
          "name": "Cocaine/cocaine metabolite IVD, kit, rapid ICT, clinical",
          "definition": "A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of cocaine and/or cocaine metabolites in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing.",
          "implantable": "false",
          "code_status": "Active"
        },
        {
          "code": "55489",
          "name": "Amphetamine/methamphetamine group IVD, kit, rapid ICT, clinical",
          "definition": "A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of multiple drugs belonging to the amphetamine and/or methamphetamine group(s) [e.g., 3,4-methylenedioxymethamphetamine (MDMA), also known as ecstasy] in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing.",
          "implantable": "false",
          "code_status": "Active"
        },
        {
          "code": "55498",
          "name": "Methamphetamine-specific IVD, kit, rapid ICT, clinical",
          "definition": "A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of a specific methamphetamine in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing.",
          "implantable": "false",
          "code_status": "Active"
        },
        {
          "code": "55701",
          "name": "Morphine/morphine metabolite IVD, kit, rapid ICT, clinical",
          "definition": "A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of morphine and/or morphine metabolites in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing.",
          "implantable": "false",
          "code_status": "Active"
        },
        {
          "code": "30521",
          "name": "Methadone IVD, kit, rapid ICT, clinical",
          "definition": "A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of methadone in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing.",
          "implantable": "false",
          "code_status": "Active"
        },
        {
          "code": "55734",
          "name": "Oxycodone IVD, kit, rapid ICT, clinical",
          "definition": "A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of oxycodone in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing.",
          "implantable": "false",
          "code_status": "Active"
        },
        {
          "code": "30523",
          "name": "Phencyclidine (PCP) IVD, kit, rapid ICT, clinical",
          "definition": "A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of phencyclidine (PCP) in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing.",
          "implantable": "false",
          "code_status": "Active"
        },
        {
          "code": "30524",
          "name": "Tricyclic antidepressant IVD, kit, rapid ICT, clinical",
          "definition": "A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of tricyclic antidepressant drugs in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing.",
          "implantable": "false",
          "code_status": "Active"
        },
        {
          "code": "30519",
          "name": "Cannabinoid/cannabinoid metabolite IVD, kit, rapid ICT, clinical",
          "definition": "A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of cannabinoids and/or cannabinoid metabolites (i.e., natural, synthetic) in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing.",
          "implantable": "false",
          "code_status": "Active"
        }
      ],
      "publish_date": "2016-08-15"
    }
  ]
}