  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-09-10",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "219265",
      "product_res_number": "Z-2456-2026",
      "event_date_initiated": "2026-03-16",
      "event_date_posted": "2026-06-16",
      "recall_status": "Open, Classified",
      "res_event_number": "98629",
      "product_code": "HSB",
      "k_numbers": [
        "K210980"
      ],
      "product_description": "TRIGEN PROXIMAL STRAIGHT HUMERAL NAIL 8/7 X 16, REF: 71760816",
      "code_info": "UDI-DI: 03596010514394. Lot/Batch: 25BM03616",
      "firm_fei_number": "1020279",
      "recalling_firm": "Smith & Nephew, Inc.",
      "address_1": "1450 E Brooks Rd",
      "city": "Memphis",
      "state": "TN",
      "postal_code": "38116-1804",
      "additional_info_contact": "901-396-2121",
      "reason_for_recall": "Humeral nail due to a manufacturing error is missing distal holes and if implanted may lead to revision surgery but, if the missing holes are identified before implantation, an equivalent backup can be used, or a bent nail of the same size, which would require additional surgical steps to address soft tissue/bone preparation, which could lead to a surgical delay of greater than 30 minutes.",
      "root_cause_description": "Process control",
      "action": "On 3/16/2026, recall notices were emailed to customers who were asked to do the following:\n1) Locate and quarantine affected devices immediately. If you have further distributed the product to other organizations, please inform them at once of this Field Action and provide to them a copy of this letter.\n3. Please complete the Customer Response form and email or fax it to your national Smith+Nephew agency/distributor.\n4. Return quarantined product to your national Smith+Nephew agency/distributor.\n5. Please maintain awareness of this notice and resulting action for an appropriate period to ensure the effectiveness of the corrective action.\n\nFirm contact information: + 1 901 396 2121, 1 800 821 5700",
      "product_quantity": "5",
      "distribution_pattern": "International distribution to the countries of BE, DE, IT.",
      "openfda": {
        "k_number": [
          "K091309",
          "K925544",
          "K013524",
          "K190321",
          "K202935",
          "K161371",
          "K253991",
          "K120419",
          "K810535",
          "K160267",
          "K913949",
          "K092110",
          "K220659",
          "K181375",
          "K093089",
          "K181296",
          "K261651",
          "K111232",
          "K050118",
          "K113828",
          "K934148",
          "K152295",
          "K022225",
          "K051624",
          "K180503",
          "K952534",
          "K990120",
          "K051678",
          "K981230",
          "K961360",
          "K051590",
          "K023241",
          "K211292",
          "K911554",
          "K250559",
          "K231343",
          "K133104",
          "K014220",
          "K971135",
          "K213328",
          "K081230",
          "K121575",
          "K230765",
          "K992856",
          "K102369",
          "K963077",
          "K972811",
          "K032898",
          "K013563",
          "K123401",
          "K142599",
          "K163368",
          "K011857",
          "K040929",
          "K950394",
          "K032523",
          "K221621",
          "K980609",
          "K033286",
          "K011622",
          "K951740",
          "K170346",
          "K073402",
          "K110322",
          "K090857",
          "K123569",
          "K232648",
          "K952739",
          "K201379",
          "K120978",
          "K200869",
          "K971056",
          "K142945",
          "K123810",
          "K010780",
          "K172774",
          "K033329",
          "K020562",
          "K101438",
          "K173129",
          "K160069",
          "K151456",
          "K981261",
          "K013923",
          "K011129",
          "K120807",
          "K912710",
          "K923580",
          "K133289",
          "K100925",
          "K210980",
          "K970280",
          "K861365",
          "K210869",
          "K915435",
          "K792203",
          "K142602",
          "K082018",
          "K163488",
          "K162927",
          "K051965",
          "K232169",
          "K965098",
          "K021027",
          "K022632",
          "K803106",
          "K961027",
          "K982873",
          "K222309",
          "K163653",
          "K012158",
          "K935383",
          "K070843",
          "K063225",
          "K131609",
          "K971816",
          "K854338",
          "K233910",
          "K130625",
          "K241651",
          "K163627",
          "K061910",
          "K183666",
          "K201147",
          "K983641",
          "K131490",
          "K101997",
          "K250622",
          "K951673",
          "K953334",
          "K093707",
          "K920598",
          "K251400",
          "K962553",
          "K252196",
          "K081243",
          "K100112",
          "K871608",
          "K021744",
          "K140601",
          "K070761",
          "K160167",
          "K933361",
          "K920666",
          "K181639",
          "K954756",
          "K010322",
          "K203399",
          "K170169",
          "K191271",
          "K820852",
          "K010988",
          "K992350",
          "K192312",
          "K810957",
          "K172189",
          "K003018",
          "K243907",
          "K260146",
          "K013449",
          "K984305",
          "K972692",
          "K161466",
          "K871947",
          "K153536",
          "K150867",
          "K122170",
          "K111352",
          "K933995",
          "K070955",
          "K810956",
          "K230352",
          "K033806",
          "K253046",
          "K200127",
          "K230071",
          "K141103",
          "K161264",
          "K172943",
          "K993670",
          "K241484",
          "K071679",
          "K143245",
          "K984602",
          "K172830",
          "K233867",
          "K912930",
          "K101622",
          "K963026",
          "K850142",
          "K132005",
          "K113303",
          "K021008",
          "K990717",
          "K091788",
          "K253749",
          "K012967",
          "K143204",
          "K241983",
          "K992063",
          "K234128",
          "K932330",
          "K150471",
          "K772081",
          "K003797",
          "K033618",
          "K023437",
          "K982601",
          "K200814",
          "K151062",
          "K032579",
          "K141347",
          "K131984",
          "K102992",
          "K011529",
          "K903256",
          "K173811",
          "K103533",
          "K922266",
          "K171108",
          "K903526",
          "K043270",
          "K954554",
          "K050882",
          "K955761",
          "K984543",
          "K160545",
          "K032097",
          "K120715",
          "K112982",
          "K070444",
          "K201567",
          "K181540",
          "K962091",
          "K100497",
          "K983339",
          "K972183",
          "K032722",
          "K172157",
          "K172628",
          "K830087",
          "K884610",
          "K042396",
          "K150655",
          "K132078",
          "K133376",
          "K182170",
          "K964243",
          "K893377",
          "K173458",
          "K981309",
          "K990436",
          "K990322",
          "K151131",
          "K133081",
          "K040336",
          "K902264",
          "K141228",
          "K930972",
          "K972813",
          "K884407",
          "K252826",
          "K001938",
          "K250628",
          "K982953",
          "K131677",
          "K221021",
          "K253517",
          "K193617",
          "K231114",
          "K021324",
          "K972108",
          "K944501",
          "K923597",
          "K922196",
          "K924656",
          "K042409",
          "K043200",
          "K113387",
          "K111891",
          "K113695",
          "K130051",
          "K250197",
          "K071944",
          "K193308",
          "K020962",
          "K813371",
          "K890936",
          "K252016",
          "K191782",
          "K811002",
          "K221221",
          "K043404",
          "K220234",
          "K033878",
          "K101934",
          "K013132",
          "K070294",
          "K172583",
          "K132945",
          "K090091",
          "K253566",
          "K032548",
          "K002057",
          "K101939",
          "K993603",
          "K960524",
          "K090478",
          "K193016",
          "K210285",
          "K984353",
          "K040462",
          "K243364",
          "K181184",
          "K021786",
          "K230257",
          "K143321",
          "K090596",
          "K143276",
          "K181640",
          "K243890",
          "K034002",
          "K083458",
          "K141447",
          "K173656",
          "K253591",
          "K142281",
          "K010801",
          "K191336",
          "K100238",
          "K982602",
          "K020885",
          "K022481",
          "K032367",
          "K982958",
          "K081356",
          "K201830",
          "K013616",
          "K151010",
          "K934643",
          "K143355",
          "K131005",
          "K013430",
          "K251850",
          "K935295",
          "K082770",
          "K230512",
          "K926232",
          "K060921",
          "K110552",
          "K072161",
          "K111056",
          "K970202",
          "K230456",
          "K933340",
          "K853250",
          "K092748",
          "K063570",
          "K020773",
          "K252961",
          "K120083",
          "K113409",
          "K053261",
          "K082754",
          "K172061",
          "K020384",
          "K022461",
          "K002783",
          "K081832",
          "K032244",
          "K013468",
          "K991790",
          "K010901",
          "K964444",
          "K122823",
          "K133166",
          "K092771",
          "K023267",
          "K102577",
          "K020677",
          "K150656",
          "K091976",
          "K031438",
          "K130147",
          "K172699",
          "K092646",
          "K152757",
          "K882443",
          "K860592",
          "K932593",
          "K012190",
          "K120148",
          "K130595",
          "K983358",
          "K170972",
          "K031219",
          "K990152",
          "K964163",
          "K233134",
          "K931256",
          "K173652",
          "K261043",
          "K191617",
          "K202099",
          "K850441",
          "K232267",
          "K083497",
          "K221115",
          "K052058",
          "K261481",
          "K131365",
          "K221031",
          "K974781",
          "K171376",
          "K141571",
          "K233696",
          "K141023",
          "K042332",
          "K112059",
          "K221084",
          "K221489",
          "K854227",
          "K050241",
          "K081152",
          "K201227",
          "K010149",
          "K161327",
          "K253080",
          "K043431",
          "K220679",
          "K021026",
          "K192163",
          "K974720",
          "K163014",
          "K962552",
          "K992850",
          "K121312",
          "K200430",
          "K163589",
          "K182307",
          "K082148",
          "K212030",
          "K871814",
          "K242247",
          "K252025",
          "K132830",
          "K933027",
          "K203819",
          "K041393",
          "K002278",
          "K884500",
          "K043052",
          "K200880",
          "K933518",
          "K870040",
          "K142451",
          "K113219",
          "K250163",
          "K201346",
          "K152370",
          "K250623",
          "K132774",
          "K111025",
          "K962561",
          "K042135",
          "K970257",
          "K970897",
          "K123745",
          "K234075",
          "K202858",
          "K253155",
          "K180436",
          "K231266",
          "K053105",
          "K150769",
          "K132428",
          "K181827",
          "K912420",
          "K993956",
          "K222390",
          "K253640",
          "K092720",
          "K100312",
          "K183162",
          "K871539",
          "K181026",
          "K033510",
          "K083437",
          "K141739",
          "K871872",
          "K111444",
          "K083726",
          "K880737",
          "K172114",
          "K173255",
          "K090241",
          "K161254",
          "K150463",
          "K202348",
          "K042440",
          "K091425",
          "K131548",
          "K083648",
          "K860756",
          "K091566",
          "K191238",
          "K102413",
          "K952923",
          "K150073",
          "K803196",
          "K922195",
          "K043233",
          "K103002",
          "K250112",
          "K980102",
          "K042325",
          "K160325",
          "K111550",
          "K081452",
          "K191598",
          "K203811",
          "K926213",
          "K801010",
          "K023115",
          "K852020",
          "K934962",
          "K973944",
          "K211086",
          "K032588",
          "K192710"
        ],
        "registration_number": [
          "",
          "3002907620",
          "1818910",
          "3010287665",
          "3003387384",
          "3048284429",
          "3016438694",
          "3004748528",
          "9617297",
          "3009973699",
          "1649379",
          "9613350",
          "2953359",
          "3004142400",
          "3008791302",
          "3011302692",
          "3013302242",
          "3010470577",
          "3010120326",
          "9610622",
          "3030412764",
          "3006217744",
          "2183449",
          "3010502940",
          "9614438",
          "3012724179",
          "3006639944",
          "3010364775",
          "3011683674",
          "1064129",
          "3006179046",
          "3006845464",
          "3009116370",
          "3015869121",
          "3034676720",
          "3015806723",
          "3043620689",
          "3015869492",
          "3006125668",
          "3004358587",
          "9681465",
          "3010041499",
          "3027339877",
          "3010370500",
          "3009971621",
          "3023852420",
          "3010097171",
          "3005144609",
          "3008951116",
          "3005059805",
          "3016084569",
          "1043653",
          "3009540749",
          "9611813",
          "3014257776",
          "3005061536",
          "3010120104",
          "1423662",
          "1051526",
          "3010106508",
          "3006513362",
          "3008599979",
          "3003249380",
          "8031020",
          "2134947",
          "3015212339",
          "3006128100",
          "3007913880",
          "3018011420",
          "3009732568",
          "3036756245",
          "3009756327",
          "3005497913",
          "3009998573",
          "2183946",
          "3015869493",
          "3007923096",
          "3009973336",
          "3021008900",
          "3016237080",
          "3007366790",
          "3008868758",
          "3010287737",
          "1935627",
          "3015946784",
          "3010047454",
          "3014967149",
          "3006946279",
          "3009554293",
          "3015440604",
          "2031966",
          "3007993775",
          "3022159082",
          "3010440433",
          "3010370880",
          "3006563559",
          "1526534",
          "3007539489",
          "2029275",
          "3006487372",
          "1833506",
          "1060840",
          "1424434",
          "3008749819",
          "3025603301",
          "3002962587",
          "1721676",
          "3011053036",
          "3009141957",
          "3014967969",
          "3010667733",
          "3010407203",
          "3010162973",
          "3043543260",
          "1828464",
          "3012392319",
          "3009812190",
          "3012663306",
          "3003541440",
          "3008812251",
          "2133928",
          "3008559295",
          "3010057495",
          "1649518",
          "3015183635",
          "8030965",
          "3004635447",
          "3016851379",
          "1058584",
          "1043534",
          "3010411051",
          "3014170143",
          "3003108161",
          "3017435639",
          "3008534770",
          "3007420745",
          "3006846753",
          "1833986",
          "3014315669",
          "2027062",
          "2249697",
          "3009380093",
          "3023272531",
          "3033509898",
          "3009381600",
          "3017521423",
          "1834331",
          "3004513872",
          "3004369035",
          "3000270450",
          "3015877656",
          "1643817",
          "3005581234",
          "1822565",
          "1529009",
          "3009158523",
          "3019767615",
          "3005874553",
          "3014314623",
          "3009888740",
          "3008650117",
          "3009189869",
          "1835444",
          "3009996260",
          "9611390",
          "3009532798",
          "3006846433",
          "3006742481",
          "3006849754",
          "3013365802",
          "3034525",
          "3021336182",
          "3031261833",
          "3006460162",
          "3009144915",
          "9615128",
          "9710312",
          "3004638532",
          "3010041430",
          "3003525643",
          "3008514120",
          "1834379",
          "1828288",
          "9613910",
          "2022435",
          "3011388423",
          "3008102042",
          "3013176080",
          "3015399803",
          "3010368646",
          "8043792",
          "1020279",
          "3006395932",
          "3003761012",
          "3009455196",
          "3008198024",
          "3007597023",
          "3014527928",
          "3012329552",
          "3030926959",
          "3009959868",
          "1422572",
          "3014273424",
          "3004983210",
          "3007344102",
          "3007593722",
          "3013820441",
          "1644408",
          "3006001176",
          "3020155054",
          "1226544",
          "3010363503",
          "3015207155",
          "3014976005",
          "3013756169",
          "3026776",
          "3008812560",
          "3016727307",
          "9610726",
          "3002949614",
          "2249615",
          "2031009",
          "3015542154",
          "3003898228",
          "3015216945",
          "3010178296",
          "3011127597",
          "3006272282",
          "3030714745",
          "1835572",
          "1054811",
          "1825034",
          "3014004349",
          "3015876273",
          "3014315560",
          "3005290844",
          "3008837339",
          "3015231789",
          "3002807295",
          "1835251",
          "3015882686",
          "3012755988",
          "2032098",
          "3004464325",
          "3014833750",
          "3010065126",
          "1221763",
          "9616944",
          "2028632",
          "3006801265",
          "3016261131",
          "3001239363",
          "3004049923",
          "3019269298",
          "3018182995",
          "3010386387",
          "1424263",
          "3003935342",
          "3025141",
          "9680825",
          "3010049501",
          "3011534620",
          "3010606097",
          "1720929",
          "3006017180",
          "3010400367",
          "1649390",
          "3004153896",
          "3010220595",
          "3010331645",
          "3009973505",
          "3011500362",
          "3000327445",
          "3010068573",
          "1835831",
          "3004450489",
          "3006783837",
          "3038503932",
          "3004976965",
          "1220246",
          "3007441485",
          "3035366890",
          "3003477135",
          "2134285",
          "3007125392",
          "8010177",
          "3010131578",
          "1833920",
          "8010916",
          "1643264",
          "3005562917",
          "3013055499",
          "1835296",
          "3010173425",
          "1220477",
          "3020704423",
          "3010462278",
          "3009417901",
          "3026311512",
          "1722511",
          "1450662",
          "3006694268",
          "1000517406",
          "3014302784"
        ],
        "fei_number": [
          "",
          "3002907620",
          "3005233524",
          "3002807305",
          "1818910",
          "3010287665",
          "3003387384",
          "3002808293",
          "3016438694",
          "3048284429",
          "3002795782",
          "3004748528",
          "3001049282",
          "3009973699",
          "1832656",
          "3004142400",
          "3008791302",
          "3003110073",
          "3011302692",
          "3013302242",
          "3010470577",
          "3010120326",
          "3001236277",
          "3006217744",
          "2183449",
          "3030412764",
          "3010502940",
          "3003058448",
          "1000306340",
          "3012724179",
          "3006639944",
          "3010364775",
          "3011683674",
          "3006179046",
          "3006845464",
          "3009116370",
          "1000115656",
          "3015869121",
          "3015806723",
          "3034676720",
          "3043620689",
          "3015869492",
          "3006125668",
          "3004358587",
          "1000306303",
          "3002924544",
          "3002807041",
          "3010370500",
          "3009971621",
          "3023852420",
          "3027339877",
          "1000143502",
          "1000125025",
          "3010097171",
          "3005144609",
          "1000114185",
          "3008951116",
          "3005059805",
          "3016084569",
          "1043653",
          "3009540749",
          "3002807830",
          "3014257776",
          "3005061536",
          "3010120104",
          "1051526",
          "3002807231",
          "3010106508",
          "3006513362",
          "3008599979",
          "3000717687",
          "3003249380",
          "3000205591",
          "3015212339",
          "3006128100",
          "3007913880",
          "3018011420",
          "3009732568",
          "3036756245",
          "3010871687",
          "3005497913",
          "3003070421",
          "3009998573",
          "3015869493",
          "3007923096",
          "3009973336",
          "1000220336",
          "3021008900",
          "3016237080",
          "3022270316",
          "3010287737",
          "3008868758",
          "1935627",
          "3015946784",
          "3010047454",
          "3014967149",
          "3006946279",
          "3009554293",
          "3015440604",
          "3007993775",
          "3022159082",
          "3010440433",
          "3010370880",
          "3006563559",
          "1526534",
          "3007539489",
          "3006487372",
          "3008749819",
          "3025603301",
          "3002962587",
          "1721676",
          "3011053036",
          "3009141957",
          "3014967969",
          "3010667733",
          "3010407203",
          "3002807036",
          "3003200961",
          "3043543260",
          "1828464",
          "3012392319",
          "3012663306",
          "3003541440",
          "3001236812",
          "3008559295",
          "3010057495",
          "3015183635",
          "3004635447",
          "3016851379",
          "3009322142",
          "1043534",
          "3010411051",
          "3014170143",
          "3003108161",
          "3017435639",
          "1000219637",
          "3000215205",
          "3008534770",
          "3007420745",
          "3006846753",
          "3000215273",
          "3014315669",
          "2027062",
          "3009380093",
          "3023272531",
          "3033509898",
          "3009381600",
          "3002807038",
          "3002594206",
          "3017521423",
          "1000125930",
          "3003356728",
          "3004369035",
          "3000270450",
          "3015877656",
          "1643817",
          "3005581234",
          "3003569173",
          "3002287318",
          "3009158523",
          "3019767615",
          "3005874553",
          "3002807172",
          "3014314623",
          "3009888740",
          "3008650117",
          "3009189869",
          "3002980729",
          "3009996260",
          "3009532798",
          "3006846433",
          "3006742481",
          "3000718467",
          "3000717902",
          "3006849754",
          "3013365802",
          "3003015552",
          "3021336182",
          "3031261833",
          "3006460162",
          "3008647423",
          "3009144915",
          "3002808269",
          "3004638532",
          "3010041430",
          "3003525643",
          "3008514120",
          "3004574120",
          "1828288",
          "2022435",
          "3002684506",
          "3011388423",
          "3013176080",
          "3015399803",
          "3010368646",
          "3002806773",
          "1020279",
          "3006395932",
          "3003761012",
          "3000718490",
          "3008198024",
          "3009455196",
          "3014527928",
          "3007597023",
          "3012329552",
          "3030926959",
          "3009959868",
          "3014273424",
          "3004983210",
          "3007344102",
          "3007593722",
          "1000306431",
          "3013820441",
          "3002807827",
          "3007282753",
          "3006001176",
          "3020155054",
          "3010363503",
          "3015207155",
          "3014976005",
          "3013756169",
          "3016727307",
          "3008812560",
          "3002949614",
          "3015542154",
          "1000220733",
          "1000139987",
          "3003898228",
          "3015216945",
          "3011127597",
          "3006272282",
          "3030714745",
          "3002806685",
          "3001452082",
          "1825034",
          "3004513872",
          "3014004349",
          "3015876273",
          "3001814066",
          "3014315560",
          "1000116912",
          "3005290844",
          "3008837339",
          "1000135253",
          "3015231789",
          "3002807295",
          "3015882686",
          "3012755988",
          "3004464325",
          "3002821504",
          "3014833750",
          "3010065126",
          "1221763",
          "1000116116",
          "3000205819",
          "3003128516",
          "3006801265",
          "3016261131",
          "3001239363",
          "3004049923",
          "3019269298",
          "3018182995",
          "3010386387",
          "1000149660",
          "3000210784",
          "3003935342",
          "3010049501",
          "3011534620",
          "3010606097",
          "1720929",
          "3006017180",
          "3010400367",
          "3008820440",
          "3004153896",
          "3010220595",
          "3010331645",
          "3009973505",
          "3011500362",
          "3000327445",
          "3010068573",
          "3004450489",
          "3038503932",
          "3004976965",
          "1220246",
          "3007441485",
          "3035366890",
          "3003477135",
          "3007125392",
          "3010131578",
          "1643264",
          "3005562917",
          "3013055499",
          "3010938185",
          "1220477",
          "3020704423",
          "3003414678",
          "3010462278",
          "3009417901",
          "3026311512",
          "3002807113",
          "1450662",
          "3006694268",
          "1000517406",
          "3014302784"
        ],
        "device_name": "Rod, Fixation, Intramedullary And Accessories",
        "medical_specialty_description": "Orthopedic",
        "regulation_number": "888.3020",
        "device_class": "2"
      }
    }
  ]
}