      "cfres_id": "219085",
      "product_res_number": "Z-1794-2026",
      "event_date_initiated": "2025-09-08",
      "event_date_posted": "2026-04-08",
      "recall_status": "Open, Classified",
      "res_event_number": "98562",
      "product_code": "LTT",
      "product_description": "MicroScan Neg Multidrug Resistant MIC 1 REF C32368\nUDI-DI code: 15099590720568\n\nIntended Use- For use with MicroScan Dried Gram Negative\nMIC/Combo Panels and Dried Gram Negative Breakpoint Combo\nPanels. MicroScan panels are designed for use in determining\nantimicrobial agent susceptibility and/or identification to the species level\nof aerobic and facultatively anaerobic gram-negative bacilli.",
      "code_info": "Catalog Number: C32368\nUDI-DI code: 15099590720568\nLot Number: 2026-05-08",
      "firm_fei_number": "2919016",
      "recalling_firm": "Beckman Coulter, Inc.",
      "address_1": "2040 Enterprise Blvd",
      "city": "West Sacramento",
      "state": "CA",
      "postal_code": "95691-3427",
      "additional_info_contact": "Kurtis Montegna\n530-990-3496",
      "reason_for_recall": "Due to manufacturing issue (incorrectly processing) with in vitro multidrug resistant test.",
      "root_cause_description": "Under Investigation by firm",
      "action": "On 09/08/2025, the firm sent via mail/email an \"URGENT FIELD SAFETY NOTICE\" to customers informing them that as a result of an internal investigation Beckman Coulter confirmed that Ciprofloxacin (Cp) antimicrobial agent was incorrectly manufactured on MicroScan Neg Multidrug Resistant MIC 1 Lot 2026-05-08.\n\nCustomers are instructed to:\n\"Review Ciprofloxacin results generated from Lot 2026-05-08 to identify any abnormal or unexpected trends in both susceptible and resistance patterns, or unexpected change in MIC trends, as compared to historical results for that same species (e.g. a sudden, unexplained increase in susceptible or % susceptible results for a species after implementation of Lot 2026-05-08 versus the previous susceptible or % susceptible results for the same species prior to using Lot 2026-05-08).\n\"Discontinue use of this lot and discard per your laboratory guidelines\n\"The laboratory should retain the inventory of other MicroScan Neg Multidrug Resistant MIC 1 lots as they are not impacted by this issue.\n\nNote-Beckman Coulter is no longer distributing MicroScan Neg Multidrug Resistant MIC 1 Lot 2026-05-08\n\nFor questions - contact Customer Support Center from website: http://www.beckmancoulter.com",
      "product_quantity": "3 boxes",
      "distribution_pattern": "International distribution to the country of Poland.",
      "openfda": {
        "k_number": [
          "K172912",
          "K123933",
          "K150039",
          "K172255",
          "K243804",
          "K250084",
          "K030620",
          "K020627",
          "K111394",
          "K033940",
          "K010508",
          "K960366",
          "K941030",
          "K001721",
          "K193358",
          "K945235",
          "K024357",
          "K983309",
          "K083262",
          "K013368",
          "K162740",
          "K003619",
          "K172337",
          "K021184",
          "K062777",
          "K011116",
          "K193536",
          "K020626",
          "K972799",
          "K935704",
          "K962150",
          "K201423",
          "K091264",
          "K983306",
          "K010159",
          "K024353",
          "K062773",
          "K021078",
          "K020160",
          "K250036",
          "K973317",
          "K131275",
          "K020939",
          "K183127",
          "K021111",
          "K010418",
          "K091949",
          "K013195",
          "K202343",
          "K993102"
        ],
        "pma_number": [
          "N62160",
          "N50494"
        ],
        "registration_number": [
          "3012389632",
          "8021914",
          "1530126",
          "1119779",
          "3031977134",
          "1924669",
          "2919016",
          "3009637528",
          "1950204",
          "3003750284",
          "3013661582",
          "3009171251",
          "3013718871"
        ],
        "fei_number": [
          "3012389632",
          "1119779",
          "3002806332",
          "3031977134",
          "1924669",
          "2919016",
          "3009637528",
          "3006759904",
          "1950204",
          "3003750284",
          "3013661582",
          "3013718871",
          "1000515493"
        ],
        "device_name": "Panels, Test, Susceptibility, Antimicrobial",
        "medical_specialty_description": "Microbiology",
        "regulation_number": "866.1640",
        "device_class": "2"
      }
    }
  ]
}