      "cfres_id": "216989",
      "product_res_number": "Z-0940-2026",
      "event_date_initiated": "2025-11-06",
      "event_date_posted": "2025-12-18",
      "recall_status": "Open, Classified",
      "res_event_number": "97894",
      "product_code": "GWJ",
      "k_numbers": [
        "K100661"
      ],
      "product_description": "MADSEN ACCUSCREEN TEOAE/DPOAE/ABR Probe (P/N 8-69-41100)",
      "code_info": "Part Number: 8-69-41100;\nUDI-DI: 04260223141355;\nSerial Numbers: 1008852, 1008888, 1008916, 1008925,\n1008935, 1008945, 1008951, 1008957,\n1008960, 1008962, 1008966, 1008967,\n1008987, 1008990, 1009054, 1009065,\n1009066, 1009131, 1009137, 1009138,\n1009139, 1009145, 1009148, 1009155,\n1009159, 1009161, 1009169, 1009184,\n1009188, 1009191, 1009305, 1009315,\n1009316, 1009319, 1009321, 1009322,\n1009325, 1009328, 1009343, 1009352,\n1009356, 1009357, 1009359, 1009366,\n1009372, 1009375, 1009376, 1009386,\n1009388, 1009390, 1009396, 1009399,\n1009400, 1009404, 1009411, 1009415,\n1009419, 1009426, 1009427, 1009432,\n1009439, 1009442, 1009454, 1009456,\n1009460, 1009463, 1009464, 1009468,\n1009475, 1009481, 1009488, 1009494,\n1009495, 1009497, 1009848, 1009855.",
      "firm_fei_number": "3008111228",
      "recalling_firm": "PATH",
      "address_1": "Landsberger Str. 65 65 landsberger str.",
      "city": "Germering",
      "country": "Germany",
      "additional_info_contact": "Dr. Johann Oswald\n+498980076502",
      "reason_for_recall": "Following a component change in the DPOAE probe (speaker replacement), technical distortions may occur at high stimulus levels combined with unusually low OAE amplitude acceptance thresholds. These distortions can mimic true DPOAE responses and may result in a false PASS outcome.",
      "root_cause_description": "Component change control",
      "action": "On November 6, 2025 URGENT: MEDICAL DEVICE Field Corrective Action letters were sent to their two distributors. Actions to be taken: - Users will be asked to confirm the DPOAE protocol in use.\n- Verify the DPOAE Protocol used is not affected by the issue (DP1, DP2,\nDP3, DP4, DP17, DP18, DP19, DP20, DP21).\n- If any other protocol is used, please replace it by using AccuLink\nSoftware. Follow instructions in IFU to do so.\n- Remove all affected protocols (DP5-DP16) using AccuLink Software.\nFollow instructions in IFU to do so.\n- Complete and return the attached form to confirm these steps were\nfollowed.\n- The expected lifetime of the probes is two years from date of\nmanufacture. Please put the products out of use, once this is reached.",
      "distribution_pattern": "Domestic: WI.\n\nInternational: Ireland.",
      "openfda": {
        "k_number": [
          "K141446",
          "K913785",
          "K103760",
          "K792085",
          "K991853",
          "K972157",
          "K926574",
          "K994149",
          "K810473",
          "K021895",
          "K813009",
          "K073626",
          "K100661",
          "K131141",
          "K092373",
          "K163326",
          "K030907",
          "K030823",
          "K111555",
          "K925648",
          "K862430",
          "K781667",
          "K070696",
          "K852687",
          "K002985",
          "K952080",
          "K043396",
          "K083399",
          "K830579",
          "K960097",
          "K193033",
          "K031051",
          "K220139",
          "K073384",
          "K780540",
          "K936039",
          "K090579",
          "K211147",
          "K862906",
          "K863156",
          "K905632",
          "K913957",
          "K862361",
          "K874193",
          "K770878",
          "K162037",
          "K993177",
          "K021215",
          "K953732",
          "K122067",
          "K143670",
          "K810138",
          "K822177",
          "K080060",
          "K082035",
          "K013137",
          "K810539",
          "K770268",
          "K863985",
          "K992807",
          "K070608",
          "K031009",
          "K870030",
          "K011842",
          "K904926",
          "K073665",
          "K013977",
          "K233649",
          "K242954",
          "K123701",
          "K862363",
          "K011746",
          "K012415",
          "K061443",
          "K132957",
          "K832510"
        ],
        "registration_number": [
          "3002504821",
          "3008773490",
          "9710051",
          "3008657524",
          "9612197",
          "3034880867",
          "3004753785",
          "3005581270",
          "3020018",
          "3008857629",
          "8021990",
          "9613619",
          "3016852448",
          "1052723",
          "3010611950",
          "9610105",
          "1651104",
          "3013500228",
          "3009973505",
          "3006177498",
          "3007048291",
          "9710602",
          "3006418479",
          "3013596024",
          "3013501110",
          "3011184129",
          "3011766844",
          "3001687738",
          "2184161",
          "1650946",
          "3015781813",
          "3007962724",
          "9612330",
          "3000279201",
          "3012182497",
          "3004046843",
          "3038189172",
          "3013679558",
          "3010536822",
          "3008483389",
          "3005877899",
          "3010900508",
          "1045254",
          "2113281",
          "3016438694",
          "3003851073",
          "9611252",
          "2023374",
          "2080783",
          "3018094310",
          "3008729547",
          "3008111228",
          "3009649442",
          "8030229",
          "3011310592",
          "3004920696",
          "3008881376"
        ],
        "fei_number": [
          "3002504821",
          "3008773490",
          "3008657524",
          "3034880867",
          "3004753785",
          "3005581270",
          "3020018",
          "3008857629",
          "3016852448",
          "1000139867",
          "3010611950",
          "3002716534",
          "3013500228",
          "3009973505",
          "3006177498",
          "3007048291",
          "3006418479",
          "3013596024",
          "3013501110",
          "3011184129",
          "3011766844",
          "3001687738",
          "3015781813",
          "3007962724",
          "3000279201",
          "3002807554",
          "3012182497",
          "3004046843",
          "3002807739",
          "3038189172",
          "3013679558",
          "3010536822",
          "3008483389",
          "3002807720",
          "3005877899",
          "3010900508",
          "3003513129",
          "1000113738",
          "1045254",
          "3000254565",
          "2113281",
          "3016438694",
          "3004674371",
          "3003851073",
          "2023374",
          "2080783",
          "3002806783",
          "3018094310",
          "3008729547",
          "3008111228",
          "3009649442",
          "3002737156",
          "3011310592",
          "3004920696",
          "3008881376",
          "2939",
          "3002809369"
        ],
        "device_name": "Stimulator, Auditory, Evoked Response",
        "medical_specialty_description": "Neurology",
        "regulation_number": "882.1900",
        "device_class": "2"
      }
    }
  ]
}