  "results": [
    {
      "cfres_id": "214865",
      "product_res_number": "Z-2167-2025",
      "event_date_initiated": "2025-06-26",
      "event_date_posted": "2025-07-30",
      "recall_status": "Open, Classified",
      "res_event_number": "97222",
      "product_code": "BZO",
      "product_description": "Breathing circuit set, coaxial, 1.80 m, with flow sensor and expiratory valve set, REF: 260128, used with HAMILTON-C1, HAMILTON-T1 and HAMILTON-MR1 ventilators.",
      "code_info": "UDI-DI: 07630002802963, Lots: 199675, 199676",
      "firm_fei_number": "3014766741",
      "recalling_firm": "Hamilton Medical AG",
      "address_1": "Parc Industrial Vial 10 10 parc industrial vial",
      "city": "Domat/Ems",
      "country": "Switzerland",
      "reason_for_recall": "Ventilator coaxial breathing circuit may have a crack in blue tubing, which is used to deliver fresh gas to the patient. The crack will compromise inspiratory and expiratory flows, leading to partial or complete rebreathing of exhaled gases, which could lead to acute hypercapnia, respiratory acidosis, and if unrecognized organ dysfunction.",
      "root_cause_description": "Process control",
      "action": "Starting on 6/26/2025, recall notices were emailed to customers who were asked to do the following:\n\nReturn affected devices.\n\nIf one of the affected breathing circuits would be already in use with a patient, it is requested to exchange it and discard the product after replacement. \n\nIf you are a distributor, please forward to any organization where potentially affected product has been transferred. \n\nComplete and return the acknowledgement form via email to complaints@hamiltonmedical.com\n\nIf you have any questions contact firm at: complaints@hamiltonmedical.com and 800-426-6331",
      "product_quantity": "2,560",
      "distribution_pattern": "US Nationwide distribution in the states of NH, NY, CT, PA, IL, ME, CO, NC, NJ, UT, TX, GA, SC, VA, IN, SD, MO, OR, TN, MA, AZ, NM.",
      "openfda": {
        "k_number": [
          "K792030",
          "K812774",
          "K833459",
          "K934753",
          "K844290",
          "K850600",
          "K813155",
          "K810341",
          "K823287",
          "K884525",
          "K850151",
          "K861286",
          "K932712",
          "K801859",
          "K823479",
          "K890011",
          "K874559",
          "K952011",
          "K850703",
          "K953784",
          "K882341",
          "K820131",
          "K791761",
          "K880637",
          "K842389",
          "K942572",
          "K760993",
          "K830923",
          "K932563",
          "K935582",
          "K896439",
          "K932706",
          "K812773",
          "K953785",
          "K921510",
          "K945740",
          "K895853",
          "K820128",
          "K823271",
          "K893760",
          "K813384",
          "K842778",
          "K830922",
          "K863033",
          "K952012",
          "K890822",
          "K880959",
          "K932560",
          "K823481",
          "K863910",
          "K770354",
          "K770581",
          "K841637",
          "K834569",
          "K911328",
          "K873927",
          "K942569",
          "K843036",
          "K922479",
          "K841378",
          "K772069",
          "K791060",
          "K801087",
          "K903083",
          "K860879",
          "K792047",
          "K832681",
          "K812737",
          "K860880",
          "K903055",
          "K791469",
          "K834570",
          "K841722",
          "K830921",
          "K860659",
          "K952022",
          "K821064",
          "K791856",
          "K770593",
          "K873900",
          "K932119",
          "K841657",
          "K944531",
          "K863756",
          "K903404",
          "K792268",
          "K952010",
          "K791034"
        ],
        "registration_number": [
          "",
          "2023529",
          "3003902312",
          "3012494290",
          "3029706818",
          "3010402691",
          "1832562",
          "3009039068",
          "9710641",
          "3007549157",
          "1000604079",
          "3017450375",
          "3042989733",
          "3011587055",
          "3016734145",
          "9615334",
          "3015084765",
          "2024500",
          "3036979319",
          "3031754334",
          "3045058049",
          "3013000203",
          "3014167550",
          "3004134948",
          "8040412",
          "2085602",
          "3026086583",
          "3011986317",
          "1836161",
          "3010834934",
          "3008567544",
          "2518436",
          "3002797442",
          "9616445",
          "9611451",
          "3006686250",
          "2026894",
          "3013505405",
          "3004824601",
          "3021244152",
          "8010042",
          "3010400865",
          "3006061749",
          "3004050971",
          "3014766741",
          "3021091708",
          "3006446479",
          "3033530343",
          "3007123976",
          "1218704",
          "9617604",
          "3006547005",
          "3010683054",
          "3012316249",
          "3010042047",
          "3008264065",
          "8043316",
          "3008566132",
          "8010939",
          "3016746538",
          "3018783526",
          "3002821232",
          "3013507143",
          "3038195661",
          "3001421318",
          "3044563261",
          "3005273623",
          "3014499739",
          "8021995",
          "3020751316",
          "3015191173",
          "3016195240",
          "3009171251",
          "1924066",
          "3008258694",
          "3008281139",
          "3006783791",
          "3011213495",
          "3008806809",
          "3013503739",
          "2518422",
          "3003965134",
          "8030673",
          "3006897516",
          "3015177409",
          "3010287621",
          "3011987967",
          "3031369651",
          "3006666710",
          "3003135857",
          "2529776",
          "3016634999",
          "3008331339",
          "2024024",
          "3031700059",
          "3038236812",
          "3023272766",
          "3029906224",
          "3011193444",
          "3008867836",
          "1417592",
          "3007573469",
          "3005767446",
          "3007709321",
          "3006563173",
          "3004531588",
          "3013557562",
          "8022265",
          "3024290085",
          "3003908598",
          "3006038729",
          "3010131137",
          "3003898360",
          "3004727093",
          "3017684630",
          "3001415205",
          "3007127332",
          "3010220595",
          "3025360937",
          "3004365956",
          "9617566",
          "9616354",
          "3030149975",
          "3029845",
          "9611500",
          "3016674860",
          "2936999",
          "3020777588",
          "3010187802",
          "3017202422",
          "1314417",
          "3011971979",
          "3003213883",
          "3011137372",
          "3014656749",
          "3000126629",
          "1824226",
          "3018094310",
          "3008342612",
          "3006534321",
          "2648727",
          "3004604967",
          "2028807",
          "3013659051",
          "3014126909",
          "3003862188",
          "3003902679",
          "3005587132",
          "3005128517",
          "3004488394",
          "3015277818",
          "3005182235"
        ],
        "fei_number": [
          "",
          "2023529",
          "3003902312",
          "3003565456",
          "3003952420",
          "3012494290",
          "3029706818",
          "3010402691",
          "1832562",
          "3009039068",
          "3007549157",
          "1000604079",
          "3017450375",
          "3042989733",
          "3011587055",
          "3016734145",
          "3015084765",
          "2024500",
          "3036979319",
          "1000115734",
          "3031754334",
          "3002750084",
          "3045058049",
          "3013000203",
          "3014167550",
          "3004134948",
          "3009271244",
          "3000210616",
          "3026086583",
          "3011986317",
          "3001104093",
          "3010834934",
          "3008567544",
          "1000374126",
          "2518436",
          "3002797442",
          "3006686250",
          "2026894",
          "3013505405",
          "3004824601",
          "3021244152",
          "3010400865",
          "3006061749",
          "3004050971",
          "3014766741",
          "3021091708",
          "3006446479",
          "3033530343",
          "3007123976",
          "3005747797",
          "3006547005",
          "3010683054",
          "3012316249",
          "3010042047",
          "3008264065",
          "3008566132",
          "3016746538",
          "3018783526",
          "3002821232",
          "3013507143",
          "3038195661",
          "3001421318",
          "3044563261",
          "3005273623",
          "3014499739",
          "3020751316",
          "3006363476",
          "3015191173",
          "3016195240",
          "3006759904",
          "3004213967",
          "1924066",
          "3008258694",
          "3008281139",
          "3006783791",
          "3011213495",
          "3008806809",
          "3013503739",
          "2518422",
          "3003965134",
          "3002808128",
          "3006897516",
          "3015177409",
          "3010287621",
          "3011987967",
          "3031369651",
          "3006666710",
          "3003135857",
          "1000121196",
          "3016634999",
          "3008331339",
          "2024024",
          "1000524541",
          "3031700059",
          "3038236812",
          "3023272766",
          "3029906224",
          "3011193444",
          "3008867836",
          "1417592",
          "3005767446",
          "3007709321",
          "3006563173",
          "3002808440",
          "3004531588",
          "3013557562",
          "3002861325",
          "3024290085",
          "3005749238",
          "3003908598",
          "3006038729",
          "3010131137",
          "3003898360",
          "3003244771",
          "3002705047",
          "3004727093",
          "3017684630",
          "3001415205",
          "3007127332",
          "3010220595",
          "3025360937",
          "3004365956",
          "3030149975",
          "3002558692",
          "3016674860",
          "3003418980",
          "2936999",
          "3020777588",
          "3002806988",
          "3010187802",
          "3017202422",
          "1314417",
          "3011971979",
          "3003213883",
          "3014656749",
          "3000126629",
          "1824226",
          "3018094310",
          "3008342612",
          "3006534321",
          "2648727",
          "3004604967",
          "3003319165",
          "3013659051",
          "3014126909",
          "3003862188",
          "3003902679",
          "3005587132",
          "3005128517",
          "3004488394",
          "3015277818",
          "3005182235"
        ],
        "device_name": "Set, Tubing And Support, Ventilator (W Harness)",
        "medical_specialty_description": "Anesthesiology",
        "regulation_number": "868.5975",
        "device_class": "1"
      }
    }
  ]
}