  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-09-17",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 3
    }
  },
  "results": [
    {
      "cfres_id": "214729",
      "product_res_number": "Z-2111-2025",
      "event_date_initiated": "2025-06-30",
      "event_date_posted": "2025-07-16",
      "recall_status": "Open, Classified",
      "res_event_number": "97176",
      "product_code": "REA",
      "product_description": "Laser light show projectors manufactured by BLS, Model DIODE 1000/2000/3000.",
      "code_info": "N/A",
      "firm_fei_number": "3021802180",
      "recalling_firm": "Beyond Laser Systems, LLC",
      "address_1": "4211 Todd Ln Ste A 4211 Todd Ln",
      "address_2": "Ste A",
      "city": "Austin",
      "state": "TX",
      "postal_code": "78744-1083",
      "additional_info_contact": "512-220-9339 Ext. 302",
      "reason_for_recall": "The remote interlock connector, which is required by 21 CFR 1040.10(f)(3), in the remote stop box was not installed the connector or was mechanically installed but not wired. The labels placed on the projectors do not meet requirements specified in 21 CFR 1010.4 (Variances), 21 CFR 1010.2 (Certification), 21 CFR 1010.3 (Identification) and 21 CFR 1040.10 (g)(Labelling requirements). The identification label does not include the date of manufacture as required by 21 CFR 1010.3.  The corrective action plan covers three families of laser light show of projectors: DIODE. CLUB and PURE with three different hardware configurations such as the number of the number of  RJ45 ports, radiant power of emissions and network configurations. No specific user manuals were provided to each model family as required by 21 CFR 1040.10(h)(1) (Informational requirements   (1) User information). The Quality Control test did not validate the manual reset function to enable resumption of laser radiation emission from Class IV laser projectors after an interruption caused using a remote interlock. No supplemental product reports, as required according to 21 CFR 1002.11.",
      "root_cause_description": "Radiation Control for Health and Safety Act",
      "action": "Beyond Laser Systems (BLS) mail the CAP letters to all affected customers. \nBLS will complete the procedure and ship the laser projector back to the customer within 14-21 days of receiving the units in our facility. BLS will provide a UPS shipping label to the customer for shipping to our facility and cover the expense of shipping the units back to the customer via UPS.\n\nIf you have any questions, call 512-220-9339 ext 302.",
      "product_quantity": "10",
      "distribution_pattern": "US Nationwide Distribution",
      "openfda": {
        "device_name": "High-Power Laser Light Show Projector",
        "medical_specialty_description": "Unknown",
        "regulation_number": "",
        "device_class": "N"
      }
    }
  ]
}