      "cfres_id": "214348",
      "product_res_number": "Z-2120-2025",
      "event_date_initiated": "2025-06-10",
      "event_date_posted": "2025-07-17",
      "recall_status": "Open, Classified",
      "res_event_number": "97047",
      "product_code": "DIH",
      "product_description": "Brand Name: VITROS Chemistry Products\nProduct Name: VITROS Chemistry Products Performance Verifier I\nModel/Catalog Number: 806 7324\nSoftware Version: Not Applicable\nProduct Description: VITROS Chemistry Products Performance Verifier is an assayed control used to monitor performance on VITROS 250/350/5,1 FS/4600/XT 3400 Chemistry Systems and the VITROS 5600/XT 7600 Integrated Systems.\n\nVITROS Performance Verifier is prepared from processed human serum to which enzymes, electrolytes, stabilizers,mpreservatives and other organic analytes have been added.\nComponent: No, not a component",
      "code_info": "Lot Code: Product Code: 806 7324 (UDI: 10758750004317)\n\nLots currently within expiry:\n\nV1665 - Exp.8/14/2025\nB2245 - Exp 3/25/2026\nY2110 - Exp. 3/25/2026\nE2828 - Exp. 2/3/2027",
      "firm_fei_number": "1000136573",
      "recalling_firm": "Ortho-Clinical Diagnostics, Inc.",
      "address_1": "100 Indigo Creek Dr",
      "city": "Rochester",
      "state": "NY",
      "postal_code": "14626-5101",
      "additional_info_contact": "Laurie O'Riordan\n954-6239546",
      "reason_for_recall": "Quality control (QC) drift when certain lots of Performance Verifiers (PVs) are used with certain lots of cholinesterase enzyme (CHE) slides. This drift occurs when the PVs are used 2-7 days after reconstitution; however, the label stability claims for the PV fluids is 7 days following reconstitution. This may lead to inaccurate QC results. The use of the PVs when the QC results are outside of the customer s established ranges could result in delayed results for patients due to the need to repeat QC testing or reconstitute new PV fluids and repeat testing. It could also result in erroneous patient results (small positive bias).",
      "root_cause_description": "Under Investigation by firm",
      "action": "On June 10, 2025, \"IMPORTANT PRODUCT CORRECTION NOTIFICATION\" letters were sent to distributors and customers. \n\nCUSTOMER LETTERS: REQUIRED ACTIONS\n\" Monitor VITROS CHE Slides QC results to detect a drift in VITROS Performance Verifiers I and II below 2x Within-lab SD limits. If QC results are below 2x WLSD, perform QC again using freshly reconstituted vials of VITROS Performance Verifiers I and II.\n\" Complete the enclosed Confirmation of Receipt form no later than June 18, 2025.\n\" Save this notification with your User Documentation or post this notification near your laboratory's fluid reconstitution location until the issue has been resolved.\n\" Please forward this notification if the affected products were distributed outside of your facility.\n\" If your laboratory has experienced the issue described in this notification and you have not already done so, please report the occurrence to your local Global Services Organization.\nQuidelOrtho's investigation is ongoing, and we are working to identify root cause. We will communicate again after root cause has been determined and the issue has been resolved. Please note that until this issue is resolved, future lots of VITROS Performance Verifiers I and II may not meet the 7-day reconstituted stability for CHE.\n\nDISTRIBUTORS: REQUIRED ACTIONS\n\" Please send the enclosed customer letter and customer Confirmation of Receipt form to all customers who have been shipped VITROS Chemistry Products Performance Verifiers AND VITROS CHE Slides from August 1, 2023, to date.\n\" Complete the enclosed distributor Confirmation of Receipt form no later than June 18, 2025.\n\" Please forward this notification if the affected products were distributed outside of your facility.\n\nIf you have further questions, please contact the Global Services Organization at 1-800-421-3311.",
      "product_quantity": "37429 units (US)/11,703 units (OUS)",
      "distribution_pattern": "Worldwide Distribution: US (nationwide) to states of: AZ, CA, FL, GA, IL, MD, MI, MO, MS, NY, TN, TX, VA; and OUS (International) to countries of: Australia, Brazil, Canada, Chile, China, Colombia, Denmark, France, Germany, India, Italy, Japan, Mexico, Netherlands, Norway, Portugal, Russia, Singapore, Spain, Sweden, and United Kingdom.",
      "openfda": {
        "k_number": [
          "K030045",
          "K862168",
          "K943367",
          "K914171",
          "K913198",
          "K791725",
          "K955498",
          "K885272",
          "K893583",
          "K001344",
          "K013750",
          "K863202",
          "K002792",
          "K103373",
          "K873496",
          "K051444",
          "K863203",
          "K863111",
          "K961656",
          "K912217",
          "K880049",
          "K912148",
          "K883890",
          "K061093",
          "K023992",
          "K880199"
        ],
        "registration_number": [
          "9610529",
          "2050012",
          "3000308930",
          "1181121",
          "1319681",
          "1832216",
          "3003502294",
          "1319809",
          "2250051",
          "2432235",
          "2085064",
          "9680746",
          "3012963943",
          "3002642396",
          "3010825766",
          "2517506",
          "3003795116",
          "9610126",
          "3014325803",
          "3006198300",
          "3005146313",
          "8040374",
          "3004493545",
          "2050010",
          "3048199746"
        ],
        "fei_number": [
          "2050012",
          "1000136573",
          "3000308930",
          "1181121",
          "1000135102",
          "1000305840",
          "1832216",
          "3003502294",
          "2250051",
          "5864",
          "2432235",
          "3012963943",
          "3002642396",
          "3010825766",
          "2517506",
          "3003795116",
          "3014325803",
          "3002806559",
          "3006198300",
          "3002806560",
          "3005146313",
          "3004493545",
          "1000206808",
          "2050010",
          "3048199746"
        ],
        "device_name": "Colorimetry, Cholinesterase",
        "medical_specialty_description": "Clinical Toxicology",
        "regulation_number": "862.3240",
        "device_class": "1"
      }
    }
  ]
}