  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-09-17",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "197558",
      "product_res_number": "Z-1008-2023",
      "event_date_initiated": "2022-12-15",
      "event_date_posted": "2023-01-20",
      "recall_status": "Open, Classified",
      "res_event_number": "91356",
      "product_code": "QJR",
      "product_description": "Revogene SARS-CoV-2_IVD real-time RT-PCR test\nintended for the qualitative detection of RNA from SARSCoV-2\nCatalog Number: 410700",
      "code_info": "UDI: N/A\nLot Numbers 410700P019, 410700P020, 410700P021, 410700P022,\n410700P023, 410700P024, 410700P027",
      "firm_fei_number": "1524213",
      "recalling_firm": "Meridian Bioscience Inc",
      "address_1": "3471 River Hills Dr",
      "city": "Cincinnati",
      "state": "OH",
      "postal_code": "45244-3023",
      "additional_info_contact": "Ryan Spradling \n800-343-3858",
      "reason_for_recall": "Leakage of the original specimen from the plastic microfluidic cartridge (PIE), possibility that laboratory personnel may be exposed to aerosolized specimen containing SARS-CoV-2",
      "root_cause_description": "Process control",
      "action": "Meridian Bioscience issued Urgent Medical Device Recall on 12/15/22 via email. The letter states reason for recall, health risk and action to take:\nREQUIRED ACTIONS:\n\" Inspect the rotor, ring, and chamber walls of the Revogene instrument for signs of leakage (e.g., dried spots). Contact Meridian Bioscience Technical Service if any signs of leakage were detected.\n\" If leakage is suspected, clean the Revogene, MOCK PIEs, and surrounding workspace using the instructions in the Revogene operator's manual.\n\" Review current inventory and segregate any remaining stock.\n\" Discontinue use of any remaining stock.\n\" Contact Meridian Technical Support 800.343.3858 to obtain a FedEx label to return any\nremaining inventory to Meridian Bioscience Inc. for credit.\n\" Complete and return the Customer Notification Form. This will indicate receipt of this field correction notice. Complete this form even if you have no remaining inventory.\n\nQuestions, please call Meridian Bioscience Technical Services at 1-800-343-3858, or email at MBI_TechService@meridianbioscience.com.",
      "product_quantity": "92 kits",
      "distribution_pattern": "US Nationwide distribution in the states of AZ, CA, IN, KS, KY, LA, MI, MN, NC, NY, OR, TX.",
      "openfda": {
        "registration_number": [
          "3010770794",
          "3004530258",
          "3008632402",
          "3007420875",
          "3004146366",
          "3016994837",
          "3002792284",
          "3009976420",
          "9615778",
          "3013540184",
          "3024647994",
          "3009613136",
          "3010607747",
          "3019837962",
          "3025663244",
          "3038610665",
          "1221359",
          "1063851",
          "2024800",
          "3003517954",
          "3004013603",
          "3016608638",
          "3003902721",
          "3014214006",
          "3017358793",
          "3017638293",
          "3004141078",
          "2031468",
          "3024756665",
          "1524213",
          "3013019728",
          "1119779",
          "3003795116",
          "3017485950",
          "3010749841",
          "3003335080",
          "3013160357",
          "9610126",
          "3005248192",
          "3011104381",
          "3009238284",
          "3009207631",
          "3009014878",
          "2243471",
          "2032682",
          "3014553740",
          "1528450",
          "3016619649",
          "3012918440",
          "3016838963",
          "2023365",
          "3008517993",
          "3009875001",
          "3032562",
          "3012758946"
        ],
        "fei_number": [
          "3010770794",
          "3004530258",
          "3008632402",
          "3002023342",
          "3007420875",
          "3004146366",
          "3016994837",
          "3002792284",
          "3009976420",
          "3013540184",
          "3024647994",
          "3025663244",
          "3009613136",
          "3010607747",
          "3019837962",
          "3038610665",
          "1221359",
          "2024800",
          "3003517954",
          "3004013603",
          "3002606748",
          "3016608638",
          "3003902721",
          "3014214006",
          "3017358793",
          "3017638293",
          "3004141078",
          "1000351505",
          "3024756665",
          "1524213",
          "3013019728",
          "1119779",
          "3003795116",
          "3017485950",
          "3003952975",
          "3010749841",
          "3003335080",
          "3013160357",
          "3005248192",
          "3011104381",
          "3009238284",
          "3009207631",
          "3002806559",
          "3009014878",
          "2243471",
          "3014553740",
          "3016619649",
          "3012918440",
          "3016838963",
          "2023365",
          "1000442352",
          "3008517993",
          "3009875001",
          "1000122536",
          "3012758946"
        ],
        "device_name": "Reagents, 2019-Novel Coronavirus Nucleic Acid",
        "medical_specialty_description": "Unknown",
        "regulation_number": "",
        "device_class": "N"
      }
    }
  ]
}