  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-09-17",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 3
    }
  },
  "results": [
    {
      "cfres_id": "192390",
      "product_res_number": "Z-0907-2022",
      "event_date_initiated": "2022-02-28",
      "event_date_posted": "2022-04-18",
      "recall_status": "Open, Classified",
      "res_event_number": "89767",
      "product_code": "MNT",
      "k_numbers": [
        "K102985"
      ],
      "product_description": "Philips Respironics V60 Ventilator (All Models, including: 1053613, 1053614, 1053615, 1053616, 1053617, 1053618, 1076709, 1076716, 1076717, 1137292, DU1053617, U1053617, R1053618, R1076709)",
      "code_info": "All Lots & Serial Numbers.  \nV60 UDI-DI:  00884838009844, 00884838009851, 00884838020054, 00884838025776, 00884838089280, 00884838090996.",
      "firm_fei_number": "2518422",
      "recalling_firm": "Respironics California, LLC",
      "address_1": "2271 Cosmos Ct",
      "city": "Carlsbad",
      "state": "CA",
      "postal_code": "92011-1517",
      "additional_info_contact": "Philips Customer Service\n1800-722-9377",
      "reason_for_recall": "Ventilator units have an issue impacting an internal electrical circuit within the ventilators, that in some cases could result in the ventilator ceasing to operate.",
      "root_cause_description": "Device Design",
      "action": "On March 14, 2022, Respironics California, LLC issued an Urgent Medical Device Correction notification to all affected consignees. On April 28, 2022 Respironics issued a revised customer communication titled Update: Urgent Medical Device Correction, dated April 20, 2022, which described mitigating actions.  On June 30, 2022, Respironics issued an Updated Urgent Medical Device Correction Notification. This letter was to provide customers with an update on Philips Respironics actions to address an issue related to the internal source (35V Rail) that powers the V60/V60 Plus ventilators. In addition, between the dates of January 23, 2023 - March 8, 2023, Respironics issued a \"Field Safety Notice\" to  customers who own the V680 model. the notification informed customers that the device will be removed from the market.   \n\nThe communication contained the following listed below:  \n\nTo address the issue with the 35V Rail, Philips Respironics will be deploying a technical solution (changing two resistors within the ventilator) that will cause the V60/V60 Plus ventilators to alarm in all cases should it experience an issue with the 35V Rail.  Philips Respironics will be contacting customers to schedule an appointment to implement the technical solution in your V60/V60 Plus ventilator(s) starting in October 2022.\n\nPhilips Respironics is offering customers a loaner EV300 ventilator while the customer awaits deployment of the technical solution in its V60/V60 Plus ventilator(s) should it be unable to implement one of the mitigations provided in the April 2022 letter. \n\nAll other information provided in the April 2022 customer communication is unchanged.  This notice needs to be provided to all those who need to be aware within your organization or to any organization where the potentially affected devices have been transferred.",
      "product_quantity": "87,138 units",
      "distribution_pattern": "Worldwide distribution   US Nationwide distribution in the states of AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, WY and the countries of Afghanistan, Albania, Algeria, American Samoa, Andorra, Argentina, Australia, Austria, Bahrain, Bangladesh, Belgium, Bhutan, Bolivia, Brazil, Bulgaria, Cambodia, Canada, Chile, China, Colombia, Comoros, Croatia, Cyprus, Czech Republic, Denmark, Ecuador, Egypt, Ethiopia, Finland, France, French Guiana, French Polynesia, Germany, Ghana, Gibraltar, Greece, Guadeloupe, Guam, Guatemala, Hong Kong, Hungary, Iceland, India, Indonesia, Iran, Iraq, Ireland, Israel, Italy, Jersey, Jordan, Kazakhstan, Kenya, Kosovo, Kuwait, Latvia, Lebanon, Libya, Luxembourg, Malaysia, Maldives, Mali, Malta, Martinique, Mauritius, Mexico, Monaco, Mongolia, Morocco, Myanmar, Namibia, Nepal, Netherlands, New Caledonia, New Zealand, Nigeria, Norway, Oman, Pakistan, Palestine, Panama, Paraguay, Peru, Philippines, Poland\t, Portugal, Puerto Rico, Qatar, R¿union,\tRomania, Russian Fed., Saudi Arabia, Singapore, Slovenia, South Africa, South Korea, Spain, St. Pier, Miquel., Sweden,\tSwitzerland, Taiwan, Tanzania, Thailand, Turkey, Ukraine, United Kingdom,  Utd. Arab. Emir., Venezuela, Vietnam, Wallis, Futuna,\tZambia,  Japan.",
      "openfda": {
        "k_number": [
          "K102985",
          "K003075",
          "K955324",
          "K113640",
          "K951264",
          "K973004",
          "K053607",
          "K213521",
          "K240779",
          "K122715",
          "K242931",
          "K990574",
          "K191624",
          "K230173",
          "K071702",
          "K082660",
          "K982454",
          "K103167",
          "K233643",
          "K170367",
          "K121623",
          "K090113",
          "K060044",
          "K252182",
          "K974539"
        ],
        "registration_number": [
          "3006783791",
          "3002797442",
          "3013190994",
          "2518422",
          "9611451",
          "3009156722",
          "3014631252",
          "3001400310",
          "3011120183",
          "3010817335",
          "9617566",
          "8010042",
          "3033526676",
          "3020283264",
          "3004428458",
          "3038562397",
          "3023272766",
          "2221819",
          "3007573469",
          "3000126629",
          "3008264065",
          "3029227324",
          "3018783526",
          "3013154126",
          "3004604967",
          "2085602",
          "3007603826"
        ],
        "fei_number": [
          "3003244771",
          "3006783791",
          "3002797442",
          "3013190994",
          "2518422",
          "3002808128",
          "3009156722",
          "3014631252",
          "3001400310",
          "3011120183",
          "3010817335",
          "3033526676",
          "3020283264",
          "3004428458",
          "3002806988",
          "3038562397",
          "3023272766",
          "2221819",
          "1000115734",
          "3000126629",
          "3008264065",
          "3029227324",
          "3018783526",
          "3013154126",
          "3004604967",
          "3000210616",
          "3007603826"
        ],
        "device_name": "Sv70 Ventilator",
        "medical_specialty_description": "Anesthesiology",
        "regulation_number": "868.5895",
        "device_class": "2"
      }
    }
  ]
}