  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-09-17",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 2
    }
  },
  "results": [
    {
      "cfres_id": "190188",
      "product_res_number": "Z-0443-2022",
      "event_date_initiated": "2021-10-21",
      "event_date_created": "2021-12-29",
      "recall_status": "Open, Classified",
      "res_event_number": "88986",
      "product_code": "LZS",
      "pma_numbers": [
        "P930016"
      ],
      "product_description": "iDesign, Model - G300: System AWS (International), System AWS (China), Advanced WaveScan Studio (United States); iDesign Refractive Studio Aberrometer (International) and (United States), Model: G301",
      "code_info": "G300 with Windows XP.\nG301 with Windows 7 Embedded System.",
      "firm_fei_number": "3006695864",
      "recalling_firm": "AMO Manufacturing USA, LLC",
      "address_1": "510 Cottonwood Dr",
      "city": "Milpitas",
      "state": "CA",
      "postal_code": "95035-7403",
      "additional_info_contact": "408-273-4100",
      "reason_for_recall": "Aberrometer and precision laser systems are affected by a remote code execution vulnerability existing when the Microsoft Windows Print Spooler service is enabled, and improperly performs privileged file operations. This could be exploited to run arbitrary code with SYSTEM privileges, allowing for program installation; view/change/deleting data; or creation of new accounts with full user rights.",
      "root_cause_description": "Software design",
      "action": "On 09/02/21, Microsoft \"PrintNightmare\" Vulnerability notices were sent to customers informing them of the upcoming software patches to remediate the vulnerability. This notice was posted on the recalling firm's website in the Security Advisories section.\n\nOn 10/21/21 correction notices started being sent to customers.  Customers were informed that Technical Service Representatives would contact then to schedule installation of the Windows OS patch. Customers were asked to do/ensure the following: 1) Complete the customer reply form, 2) To safeguard patients form potential harm and to inform them what to do in the event of product malfunction, customers were directed to specific parts of the Instructions for Use. 3) Confirm all measurements against baseline pre-operative manifest refraction and do not proceed when outside of recommended limits of difference, for sphere, cylinder and axis, as specified in the operators manual and training material. 4) Maintain manual records of patient measurements. 5) Ensure you comply with obligations under applicable privacy laws relating to putting in place safeguards in connection with personal information for patients. Customers with additional questions were encouraged to call Technical Support at 1 (800)- 511-0911.",
      "product_quantity": "711",
      "distribution_pattern": "US: CA, TX, FL, LA, MD, IA, MA, VA, SD, MN, MO, NC, TN, SC, WA, NV, OH, KY, IN, CO, NJ, OK, NH, UT, AR, NY, AK, ND, NE, IL, AL, HI, CT, DE, KS, GA, OR, MS, PA, MT, ME, MI, AZ, ID, WI, VT, NM, CA.\n\n\nOUS: Canada, Mexico, Russian Federation, Turkey, Brazil, Egypt, Iraq, Saudi Arabia, Jordan, Norway, Colombia, Germany, Malaysia, India, Oman, Azerbaijan, Canada, Slovakia, Lebanon, Spain, Ireland, Italy, South Korea, Bangladesh, Chile, Taiwan, Tunisia, Kazakhstan, Libya, Argentina, Singapore, Austria, Australia, Vietnam, Greece, Poland, Indonesia, Yemen, Great Britain, South Africa, Croatia, France, Czech Republic, Algeria, Thailand, Bulgaria, United Arab Emirates, Belgium, Japan, China, Nepal, Israel, Switzerland, Dominican Republic, Hong Kong, Portugal, Ecuador, Kuwait, Netherlands, Slovenia, Philippines",
      "openfda": {
        "pma_number": [
          "P030008",
          "P910067",
          "P990027",
          "P060004",
          "P960019",
          "P970056",
          "P020050",
          "P930034",
          "P910062",
          "P980008",
          "P970043",
          "P990010",
          "P970005",
          "P970053",
          "P930016"
        ],
        "registration_number": [
          "3012236936",
          "3002807715",
          "3006695864",
          "9710340",
          "9615030",
          "2936921",
          "3038356864",
          "1920664",
          "3007606649",
          "8030392",
          "3003288808"
        ],
        "fei_number": [
          "3002483854",
          "3012236936",
          "3002807715",
          "3006695864",
          "2936921",
          "3038356864",
          "3003691824",
          "3001362763",
          "1920664",
          "3003288808"
        ],
        "device_name": "Excimer Laser System",
        "medical_specialty_description": "Unknown",
        "regulation_number": "",
        "device_class": "3"
      }
    }
  ]
}