  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-09-05",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "183989",
      "product_res_number": "Z-0426-2021",
      "event_date_initiated": "2020-10-01",
      "event_date_created": "2020-11-06",
      "recall_status": "Open, Classified",
      "res_event_number": "86516",
      "product_code": "QKO",
      "product_description": "EDI Novel Coronavirus COVID-19 IgG ELISA Kit, REF: KT-1032\n \nPer label: This kit is intended for qualitative detection of human anti-COVID-19 IgG antibody in human serum. This kit is to be used as an aid for the detection of novel COVID-19. Patients with suspected clustering cases require diagnosis or differential diagnosis of novel coronavirus infection.",
      "code_info": "Lot Numbers: P826, P815, P796, P776",
      "firm_fei_number": "3004185580",
      "recalling_firm": "Epitope Diagnostics, Inc.",
      "address_1": "7110 Carroll Rd",
      "city": "San Diego",
      "state": "CA",
      "postal_code": "92121-2215",
      "additional_info_contact": "858-693-7877",
      "reason_for_recall": "The use of deionized water rather than distilled water during the manufacturing process, may have resulted in accelerated decreased OD signals for the Positive Control value.",
      "root_cause_description": "Nonconforming Material/Component",
      "action": "On 10/01/20, the firm, Epitope Diagnostics Inc. (EDI), sent \"URGENT: EDI\" Novel Coronavirus COVID-19 IgG ELISA Kit Recall\" notices were sent to customers.  Customers were asked to do the following: Results where the assay controls do not meet the manufacturer's defined specifications should be considered invalid and repeated with another lot.  Immediately examine your inventory and quarantine product subject to recall. In addition, if you have further distributed this product, please identify your customers and notify them at once of this product recall. Complete and promptly return the Customer Response Form by Email to: cs@epitopediagnostics.com or Fax to: 858-693-7877. Your notification to your customers may be enhanced by including a copy of this recall notification letter.  For customers located within United States, we will ask that you return this affected product to the recalling firm.  For customers located outside United States, please destroy the affected product.\n\nFor any questions, please refer to EDIs Quality Assurance and Regulatory Affairs Manager, Stefanie Dallezotte, by email: lenart@epitopediagnostics.com or by telephone: +1 858 693 7877.",
      "product_quantity": "2886",
      "distribution_pattern": "U.S Distribution.: NH, CO, OR, CA, FL, NY, MD, NJ, IL, NC, MI, TX, PA, MA, OH, NM, VA, SC, HI, and TN.",
      "openfda": {
        "registration_number": [
          "1318354",
          "3005094123",
          "3009014878",
          "3024756665",
          "8023060",
          "1832216",
          "3016850770",
          "2032900",
          "1319681",
          "3009585529",
          "3003917514",
          "3002792284",
          "3016761091",
          "3011522054",
          "2182595",
          "2025099",
          "9610240",
          "3009092698",
          "3012289707",
          "2242436",
          "1063851",
          "3016764932",
          "3013332582",
          "3017379203",
          "3014022295",
          "3002642396",
          "3000308930",
          "2431980",
          "3007361513",
          "3014862351",
          "2521625",
          "3012963943",
          "3016610313",
          "3005984081",
          "3007118747",
          "3032562",
          "3008517993",
          "3008344661",
          "2250051",
          "3035708936",
          "3013530901",
          "3010610113",
          "3038560224",
          "1415939",
          "2020726",
          "2031229",
          "9610126",
          "3007111389",
          "2029372",
          "3005333358",
          "3026565854",
          "3010934853",
          "3003795116",
          "3003268355",
          "3009238284",
          "2032682",
          "3026664926",
          "3007349751",
          "3033507883",
          "3016820006"
        ],
        "fei_number": [
          "1318354",
          "3005094123",
          "3004445302",
          "3000719950",
          "3002806559",
          "3009014878",
          "3024756665",
          "1832216",
          "3003952975",
          "3016850770",
          "3009585529",
          "3003917514",
          "3002792284",
          "3016761091",
          "3002606748",
          "3011522054",
          "2182595",
          "3002808212",
          "1000442352",
          "3009092698",
          "3012289707",
          "2242436",
          "3007981058",
          "3016764932",
          "3013332582",
          "3017379203",
          "3014022295",
          "3002642396",
          "3000308930",
          "2431980",
          "3007361513",
          "3014862351",
          "2521625",
          "3012963943",
          "3016610313",
          "3005984081",
          "3007118747",
          "1000306617",
          "3008517993",
          "3008344661",
          "2250051",
          "3035708936",
          "3013530901",
          "3010610113",
          "3038560224",
          "1415939",
          "2020726",
          "3007111389",
          "3005333358",
          "3026565854",
          "3010934853",
          "3003795116",
          "1000136573",
          "3009238284",
          "3003268355",
          "3026664926",
          "3007349751",
          "3033507883",
          "3016820006",
          "3003992026"
        ],
        "device_name": "Reagent, Coronavirus Serological",
        "medical_specialty_description": "Unknown",
        "regulation_number": "",
        "device_class": "N"
      }
    }
  ]
}