  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-09-05",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "181951",
      "product_res_number": "Z-2418-2020",
      "event_date_initiated": "2020-06-08",
      "event_date_posted": "2020-06-23",
      "recall_status": "Open, Classified",
      "res_event_number": "85857",
      "product_code": "IKK",
      "product_description": "Lokomat Pro, Catalog Numbers 30003 LokomatPro L6.2 120V AD \n; 30004 LokomatPro L6.2 120V Kombi; \n30005 LokomatPro L6.2 120V PE; \n30683 LokomatPro L6.2 110V FD PE; \n30684 LokomatPro L6.2 110V FD Kombi; \n32001 LokomatPro L6.2 110V FD AD\nProduct Usage: The intended use of the Lokomat is to support treadmill training to treat patients with walking disabilities caused by neurological, muscular or bone-related disorders. isokinetic testing and evaluation system",
      "code_info": "All units",
      "firm_fei_number": "3003781275",
      "recalling_firm": "Hocoma AG",
      "address_1": "Industriestrasse 4 4 industriestrasse",
      "city": "Volketswil",
      "country": "Switzerland",
      "additional_info_contact": "Kevin Walls\n720-9625412",
      "reason_for_recall": "The motor controller may fail, which can potentially lead to an error in functionality of the Body Weights Support Rope, which means that the rope can go up or down in an uncontrolled way.",
      "root_cause_description": "Device Design",
      "action": "The firm began notifying affected customers on June 8, 2020. Customers were informed that the motor-controller in their Lokomat may fail, potentially leading to an unintended error in functionality of the Body Weights Support Rope which means that the rope can go up or down in an uncontrolled way.\n\nTo minimize a risk in relation to a potential failure of the motor-controller, the firm advises you to do the following:\n- As indicated in the Instruction for Use, permanently monitor patients, which perform a training with the Lokomat. The scenario is especially critical for pediatric patients.\n- In any case of unusual behavior of the Body Weight Support Rope (e.g. the rope goes up unintendedly) immediately press the Emergency button on the handrail or on the Tele Stop in order to stop the treadmill and the orthosis. Immediately afterwards switch off the power supply in order to stop the rope going up. Afterwards release the patient with the emergency release knob. See Details attached.\n- Make sure that all possible users of the Lokomat in your institution are informed of this temporary precautionary approach.\n\nThe firm will continue to work on a technical solution to further minimize the risk of the potential motor control failure.",
      "product_quantity": "494",
      "distribution_pattern": "Worldwide distribution - US Nationwide distribution including in the states of FL, GA, IL, MI, MN, MO, NE, NY, TX.",
      "openfda": {
        "k_number": [
          "K862993",
          "K123746",
          "K880018",
          "K860821",
          "K944732",
          "K924414",
          "K915648",
          "K915144",
          "K896553",
          "K844368",
          "K922772",
          "K902219",
          "K871557",
          "K861986",
          "K862997",
          "K875235",
          "K923350",
          "K862096",
          "K844060",
          "K884487",
          "K832770",
          "K863313",
          "K951916",
          "K861632",
          "K841849",
          "K862998",
          "K905525",
          "K861206",
          "K904898",
          "K950095",
          "K895236",
          "K862780",
          "K872911",
          "K894662",
          "K880230",
          "K842296",
          "K862995",
          "K903429",
          "K861622",
          "K862996",
          "K911666",
          "K843739",
          "K862994",
          "K942229",
          "K915846",
          "K900741",
          "K911805",
          "K895398",
          "K913020",
          "K951770",
          "K913021",
          "K901566",
          "K872199",
          "K871793",
          "K873659",
          "K952090",
          "K880017",
          "K881681",
          "K922092",
          "K881676",
          "K900450"
        ],
        "registration_number": [
          "3027669735",
          "",
          "3017488401",
          "3045924795",
          "1530895",
          "3016678950",
          "3012251430",
          "3018993530",
          "3014655115",
          "3013729860",
          "3017207289",
          "3027153106",
          "3018091330",
          "3042971389",
          "3044087174",
          "3014150341",
          "3003454229",
          "3010817595",
          "3035374386",
          "3000126629",
          "3013846071",
          "3042285056",
          "3046001638",
          "3017435710",
          "3032587540",
          "3023272766",
          "8021957",
          "3036471706",
          "3017264244",
          "3018188848",
          "3034676730",
          "3027641464",
          "3011806255",
          "3004979815",
          "3045713381",
          "1224631",
          "3016569182",
          "3003074886",
          "3009522766",
          "3027717071",
          "3013695823",
          "3032772580",
          "3018783526",
          "3011803487",
          "3009714286",
          "3008887767",
          "3014083954",
          "3036496409",
          "3015134044",
          "3029906445",
          "3015060244",
          "3002104323",
          "3024676737",
          "2431314",
          "1119903",
          "3003193933",
          "3013839994"
        ],
        "fei_number": [
          "3027669735",
          "",
          "3017488401",
          "3045924795",
          "3016678950",
          "3012251430",
          "3018993530",
          "3014655115",
          "3013729860",
          "3017207289",
          "3027153106",
          "3018091330",
          "3042971389",
          "1000480800",
          "3044087174",
          "3014150341",
          "3003454229",
          "3010817595",
          "3035374386",
          "3000126629",
          "3013846071",
          "3042285056",
          "3046001638",
          "3017435710",
          "3032587540",
          "3023272766",
          "3036471706",
          "3017264244",
          "3018188848",
          "3034676730",
          "3027641464",
          "3768",
          "3011806255",
          "3004979815",
          "3045713381",
          "3016569182",
          "3003074886",
          "3009522766",
          "3027717071",
          "3013695823",
          "3032772580",
          "3018783526",
          "3011803487",
          "3009714286",
          "3008887767",
          "3014083954",
          "3036496409",
          "3015134044",
          "3029906445",
          "1000514085",
          "3015060244",
          "3002104323",
          "3024676737",
          "2431314",
          "1119903",
          "3003193933",
          "3013839994"
        ],
        "device_name": "System, Isokinetic Testing And Evaluation",
        "medical_specialty_description": "Physical Medicine",
        "regulation_number": "890.1925",
        "device_class": "2"
      }
    }
  ]
}