  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-09-05",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 3
    }
  },
  "results": [
    {
      "cfres_id": "177798",
      "product_res_number": "Z-0728-2020",
      "event_date_initiated": "2019-11-14",
      "event_date_created": "2019-12-20",
      "recall_status": "Open, Classified",
      "res_event_number": "84228",
      "product_code": "NIO",
      "pma_numbers": [
        "P020036"
      ],
      "product_description": "S.M.A.R.T. Nitinol Stent System and the S.M.A.R.T. Control Nitinol Stent System.   \nThe SMART stent system includes a self-expanding stent made of Nitinol (nickel-titanium alloy) material and a 6 French (2.0 mm) or 7 French (2.3 mm) sheathed delivery system.  The stent is laser cut from a solid nitinol tube into a fine mesh ( Z  Configuration) design.  The stent expands to its unconstrained diameter when released from the deployment catheter into the iliac artery.  Upon deployment, the stent forms an open lattice and pushes outward on the luminal surface, helping to maintain the patency of the artery.  Due to the self-expanding behavior of nitinol, the stents are indicated for placement into vessels that are 1-2 mm smaller in diameter than the unconstrained diameter of the stent.\nThe SMART Control stent system includes a self-expanding stent made of Nitinol (nickel-titanium alloy) material and a 6 French (2.0 mm) sheathed delivery system.  The stent is laser cut from a solid nitinol tube into a fine mesh ( Z  Configuration) design.  The stent expands to its unconstrained diameter when released from the deployment catheter into the iliac artery.  Upon deployment, the stent forms an open lattice and pushes outward on the luminal surface, helping to maintain the patency of the artery.  Due to the self-expanding behavior of nitinol, the stents are indicated for placement into vessels that are 1-2 mm smaller in diameter than the unconstrained diameter of the stent.  The stent is equipped with 12 tantalum markers, 6 at each end, to increase the visibility of the stent under fluoroscopic imaging.  The SMART Control stent system is designed to be delivered through an appropriately sized catheter sheath introducer.",
      "code_info": "All Lot Codes.  Affected SKUs:  N1020ABR, N1020BBR, N1020TBR, N1040ABR, N1040BBR, N1040EBR, N1040TBR, N1060ABR, N1060BBR, N1060EBR, N1060TBR, N1080ABR, N1080BBR, N1080EBR, N1080TBR, N6120BV, N620ABR, N620BBR, N620TBR, N640ABR, N640BBR, N640TBR, N660ABR, N660BBR, N660TBR, N680ABR, N680BBR, N680TBR, N7120BV, N720ABR, N720BBR, N720TBR, N740ABR, N740BBR, N740TBR, N760ABR, N760BBR, N760TBR, N780ABR, N780BBR, N780TBR, N8120BV, N820ABR, N820BBR, N820TBR, N840ABR, N840BBR, N840EBR, N840TBR, N860ABR,  N860BBR, N860EBR, N860TBR, N880ABR, N880BBR, N880EBR, N880TBR, N920ABR, N920BBR, N920TBR, N940ABR, N940BBR, N940TBR, N960ABR, N960BBR, N960TBR, N980ABR, N980BBR, N980TBR.",
      "firm_fei_number": "3004008697",
      "recalling_firm": "Cardinal Health Inc.",
      "address_1": "7000 Cardinal Pl",
      "city": "Dublin",
      "state": "OH",
      "postal_code": "43017-1091",
      "additional_info_contact": "Cordis Endovascular Medical Info Line\n877-338-4235",
      "reason_for_recall": "Cordis has initiated a labeling correction for S.M.A.R.T. and PRECISE stents due to incorrect MRI information on the IFU.  The correct classification is \"MRI Conditional\" not \"MRI Safe\".",
      "root_cause_description": "Under Investigation by firm",
      "action": "Customers were notified with a Medical Device Correction letter.  The letter was sent via overnight delivery beginning 11/14/2019.  The letter identified affected product, provided a description of the problem, and asked that a copy of the letter be retained where the product is stored.  Customer were asked to completed and return an Acknowledgement Form.  Questions can be directed to the Cordis Endovascular Medical Information Line 877-DEVICE5 (877-338-4235) Monday through Friday 9:00 am - 5:00 pm EST.",
      "product_quantity": "267,247 units total (262,641 OUS, 4,606 US)",
      "distribution_pattern": "Worldwide distribution - US Nationwide including Puerto Rico and countries of Algeria, Argentina, Armenia, Australia, Austria, Azerbaiian, Azerbaijan, Bahrain, Bangladesh, Belarus, Belgium, Brazil, Bulgaria, Canada, Chile, China, Colombia, Costa Rica, Czech Repulic, Denmark, Dominican Republic, Ecuador, Egypt, Estonia, Finland, France, Germany, Guatemala, Hong Kong, Hungary, India, Indonesia, Iran, Iraq, Ireland, Israel, Italy, Japan, Jordan, Kazakhstan, Kenya, Korea, Kuwait, Latvia, Lebanon, Libya, Lithuania, Luxembourg, Malaysia, Maldives, Malta, Martinique, Mexico, Morocco, Netherlands, New Caledonia, New Zealand, Norway, Oman, Panama, Peru, Philippines, Poland, Portugal, Qatar, Russian Federation, Saint-Barthelemy, Saudia Arabia, Sinapore, Slovakia, South Africa, Spain, Sweden, Switzerland, Thailand, Turkey, Ukraine, United Arab Emirates, United Kingdom, Uruguay, Venezuela.",
      "openfda": {
        "pma_number": [
          "P030045",
          "P080007",
          "P110035",
          "P110028",
          "P140030",
          "P110043",
          "P940019",
          "P140002",
          "P090006",
          "P020036",
          "P890017",
          "P090003",
          "P050017",
          "P110011",
          "P060001"
        ],
        "registration_number": [
          "3009526575",
          "9681442",
          "3014656749",
          "1643817",
          "3004091615",
          "3002504068",
          "2024024",
          "1225687",
          "3010273872",
          "9616099",
          "3011574793",
          "3005111382",
          "9681260",
          "9616666",
          "2183744",
          "2134265",
          "3001845648",
          "2124215",
          "3002807314",
          "2939561",
          "2183870",
          "8010026",
          "1531050",
          "2024168",
          "2020394",
          "3010220595",
          "3006082230",
          "1000121056",
          "3005718570",
          "1018233",
          "9681834",
          "3005941719",
          "3005580113",
          "8043892",
          "1058584",
          "1016427",
          "3002807090"
        ],
        "fei_number": [
          "3002095335",
          "3009526575",
          "3002806368",
          "1643817",
          "3004091615",
          "3002504068",
          "3006003617",
          "3008906816",
          "2024024",
          "1000219637",
          "3010273872",
          "2828",
          "3011574793",
          "3005111382",
          "3004635528",
          "3002755653",
          "3001845648",
          "2183744",
          "3002808327",
          "2124215",
          "3002807314",
          "2183870",
          "2024168",
          "3002808050",
          "2020394",
          "3010220595",
          "3002806565",
          "1000121056",
          "3005718570",
          "3006082230",
          "3003528016",
          "1018233",
          "3002807111",
          "3005580113",
          "3001451463",
          "1016427",
          "3014656749"
        ],
        "device_name": "Stent, Iliac",
        "medical_specialty_description": "Unknown",
        "regulation_number": "",
        "device_class": "3"
      }
    }
  ]
}