      "cfres_id": "172725",
      "product_res_number": "Z-1718-2019",
      "event_date_initiated": "2019-05-09",
      "event_date_created": "2019-06-04",
      "recall_status": "Open, Classified",
      "res_event_number": "82796",
      "product_code": "HRS",
      "k_numbers": [
        "K063166"
      ],
      "product_description": "Rim Plate, 10-Hole, Left, PRS RX System.  Titanium, implantable - Product Usage: The implant temporarily stabilizes bone segments until bony consolidation has taken place. After this, the implant has no more use and can be removed.",
      "code_info": "Model Number: 21206-10;  Lot Code: 26/F42778",
      "firm_fei_number": "3004369035",
      "recalling_firm": "I.T.S. GmbH",
      "address_1": "Autal 28 28 autal",
      "city": "Lasnitzhohe",
      "country": "Austria",
      "reason_for_recall": "The titanium implant has the wrong article number laser marked on it.",
      "root_cause_description": "Labeling mix-ups",
      "action": "I.T.S. GmbH notified international consignees initially on about 05/09/2019,  via an updated \"Urgent Notice MEDICAL DEVICE RECALL\" letter, and US customers were notified to quarantine affected devices.  On about 05/13/2019, US customers were notified via an updated \"Urgent Notice MEDICAL DEVICE RECALL\" letter.  \n\nCustomers were instructed to immediately review their inventory to identify and remove all affected products listed above in a manner that ensures the affected products will not be used, review, complete, sign and return the attached reply form and send it back within 5 business days of receipt of the notification, return any affected product as soon as possible within 30 business days and include a copy of this notification,  and forward the recall notification to any appropriate parties that need to be informed about this recall.  lf any of the affected products have been forwarded to another facility, customers were instructed to contact that facility to arrange return and provide them with a copy of the recall notification.  A copy of this letter was instructed to be kept.",
      "product_quantity": "65 devices",
      "distribution_pattern": "Worldwide distribution - US nationwide distribution in the states of Florida and Puerto Rico, and countries of Austria, Netherlands, Slovenia, South Africa, Switzerland.",
      "openfda": {
        "k_number": [
          "K050868",
          "K970258",
          "K191057",
          "K163046",
          "K011334",
          "K913289",
          "K111678",
          "K190385",
          "K233154",
          "K050607",
          "K040588",
          "K230591",
          "K973204",
          "K130185",
          "K232693",
          "K100944",
          "K151508",
          "K253718",
          "K161861",
          "K172441",
          "K261002",
          "K223933",
          "K203405",
          "K131480",
          "K151019",
          "K112819",
          "K051165",
          "K112923",
          "K221150",
          "K120163",
          "K120818",
          "K111266",
          "K163044",
          "K203294",
          "K233994",
          "K000066",
          "K120787",
          "K014197",
          "K143496",
          "K191412",
          "K211051",
          "K083573",
          "K983419",
          "K132787",
          "K251296",
          "K230938",
          "K231441",
          "K091614",
          "K090983",
          "K122293",
          "K121437",
          "K121672",
          "K120070",
          "K082624",
          "K131380",
          "K192619",
          "K100146",
          "K183321",
          "K091479",
          "K223772",
          "K213123",
          "K172148",
          "K936233",
          "K020602",
          "K101536",
          "K022231",
          "K040850",
          "K102352",
          "K000636",
          "K162380",
          "K090786",
          "K230690",
          "K945137",
          "K061808",
          "K113109",
          "K143523",
          "K071264",
          "K983967",
          "K101936",
          "K172178",
          "K233017",
          "K113601",
          "K242995",
          "K253660",
          "K243357",
          "K162154",
          "K200575",
          "K193222",
          "K070170",
          "K240173",
          "K251913",
          "K181533",
          "K221938",
          "K180554",
          "K052901",
          "K210192",
          "K141430",
          "K251892",
          "K130510",
          "K110476",
          "K201656",
          "K112174",
          "K050681",
          "K141548",
          "K161303",
          "K163650",
          "K112663",
          "K141992",
          "K160553",
          "K143385",
          "K994158",
          "K171293",
          "K173641",
          "K121826",
          "K171285",
          "K172008",
          "K854825",
          "K170780",
          "K925571",
          "K152289",
          "K230204",
          "K153374",
          "K142484",
          "K052041",
          "K922167",
          "K875086",
          "K060041",
          "K930966",
          "K190388",
          "K100618",
          "K040938",
          "K190670",
          "K181067",
          "K253423",
          "K870082",
          "K182785",
          "K091294",
          "K131759",
          "K213895",
          "K053624",
          "K864924",
          "K151407",
          "K231213",
          "K253713",
          "K041965",
          "K142938",
          "K141489",
          "K974908",
          "K092381",
          "K201578",
          "K102505",
          "K243569",
          "K112455",
          "K201918",
          "K140531",
          "K092317",
          "K171852",
          "K200513",
          "K093983",
          "K252061",
          "K033456",
          "K241356",
          "K850442",
          "K200108",
          "K140792",
          "K182015",
          "K133246",
          "K051155",
          "K223853",
          "K212487",
          "K170457",
          "K243987",
          "K203817",
          "K051884",
          "K200961",
          "K212601",
          "K260291",
          "K162974",
          "K093772",
          "K201229",
          "K890641",
          "K141825",
          "K021626",
          "K931687",
          "K210043",
          "K250620",
          "K984390",
          "K192021",
          "K150520",
          "K190842",
          "K982982",
          "K163593",
          "K950618",
          "K092419",
          "K252166",
          "K193639",
          "K982347",
          "K190992",
          "K951415",
          "K252897",
          "K191009",
          "K922525",
          "K931690",
          "K202914",
          "K012162",
          "K143394",
          "K073344",
          "K162391",
          "K123241",
          "K191344",
          "K063009",
          "K051083",
          "K210658",
          "K093880",
          "K211592",
          "K222637",
          "K030858",
          "K170771",
          "K220244",
          "K163383",
          "K060514",
          "K061211",
          "K133715",
          "K980368",
          "K083654",
          "K172170",
          "K243740",
          "K051735",
          "K130340",
          "K063820",
          "K252661",
          "K151379",
          "K250055",
          "K910482",
          "K222381",
          "K183317",
          "K121302",
          "K153482",
          "K063095",
          "K102694",
          "K221346",
          "K141383",
          "K982531",
          "K090582",
          "K062216",
          "K921622",
          "K063726",
          "K961485",
          "K233089",
          "K172294",
          "K241018",
          "K011335",
          "K211582",
          "K073556",
          "K905355",
          "K931693",
          "K251620",
          "K171510",
          "K063303",
          "K101421",
          "K930480",
          "K914803",
          "K223118",
          "K152145",
          "K192323",
          "K211843",
          "K123832",
          "K081374",
          "K072818",
          "K111253",
          "K031493",
          "K052390",
          "K063460",
          "K234062",
          "K061352",
          "K002486",
          "K133102",
          "K100176",
          "K033519",
          "K180821",
          "K913355",
          "K193614",
          "K111419",
          "K060473",
          "K262537",
          "K133668",
          "K093868",
          "K152256",
          "K092670",
          "K221088",
          "K110700",
          "K020221",
          "K254002",
          "K110201",
          "K050492",
          "K192217",
          "K123000",
          "K070208",
          "K022325",
          "K063831",
          "K202307",
          "K984458",
          "K092556",
          "K972479",
          "K254253",
          "K163003",
          "K070946",
          "K993106",
          "K203834",
          "K181587",
          "K132886",
          "K974309",
          "K060476",
          "K950105",
          "K112169",
          "K111086",
          "K100502",
          "K042205",
          "K931692",
          "K221412",
          "K050110",
          "K163086",
          "K241599",
          "K020872",
          "K142135",
          "K153573",
          "K130964",
          "K051181",
          "K052152",
          "K083364",
          "K974289",
          "K132876",
          "K143365",
          "K081608",
          "K041860",
          "K972223",
          "K151468",
          "K092609",
          "K061098",
          "K182201",
          "K910175",
          "K142823",
          "K260228",
          "K140431",
          "K905024",
          "K972913",
          "K102998",
          "K192675",
          "K091243",
          "K152242",
          "K862254",
          "K031666",
          "K142724",
          "K014155",
          "K161896",
          "K921338",
          "K991873",
          "K100240",
          "K261207",
          "K092528",
          "K051410",
          "K221465",
          "K250929",
          "K092812",
          "K142502",
          "K071563",
          "K121495",
          "K150456",
          "K190658",
          "K122005",
          "K120651",
          "K093978",
          "K100111",
          "K202489",
          "K162898",
          "K132594",
          "K242343",
          "K931683",
          "K092078",
          "K142906",
          "K162424",
          "K102689",
          "K203479",
          "K161703",
          "K142943",
          "K052248",
          "K171320",
          "K192696",
          "K915315",
          "K073115",
          "K193616",
          "K971870",
          "K083032",
          "K152000",
          "K052368",
          "K122623",
          "K242436",
          "K163039",
          "K011978",
          "K213698",
          "K942032",
          "K011076",
          "K243491",
          "K040860",
          "K233311",
          "K080184",
          "K950115",
          "K932352",
          "K202764",
          "K230546",
          "K082527",
          "K002775",
          "K212581",
          "K090289",
          "K082399",
          "K210935",
          "K931679",
          "K952766",
          "K210060",
          "K130108",
          "K180808",
          "K051945",
          "K260448",
          "K181872",
          "K260353",
          "K924085",
          "K193543",
          "K030877",
          "K172786",
          "K162674",
          "K170547",
          "K051032",
          "K093474",
          "K190415",
          "K090304",
          "K062564",
          "K172973",
          "K182402",
          "K041786",
          "K840954",
          "K141734",
          "K133525",
          "K190365",
          "K250155",
          "K033918",
          "K130008",
          "K100123",
          "K251050",
          "K143066",
          "K030909",
          "K182810",
          "K182718",
          "K200538",
          "K023802",
          "K200785",
          "K152548",
          "K191867",
          "K243275",
          "K042437",
          "K761150",
          "K931685",
          "K052294",
          "K163425",
          "K081407",
          "K213591",
          "K071549",
          "K051412",
          "K110662",
          "K052011",
          "K052150",
          "K260274",
          "K242939",
          "K111039",
          "K190750",
          "K082300",
          "K071715",
          "K143050",
          "K241942",
          "K233863",
          "K895243",
          "K070241",
          "K182492",
          "K850025",
          "K122770",
          "K131311",
          "K232515",
          "K072832",
          "K051567",
          "K190963",
          "K171624",
          "K983853",
          "K913271",
          "K213069",
          "K151735",
          "K042598",
          "K141527",
          "K103243",
          "K931691",
          "K140724",
          "K080667",
          "K182650",
          "K151732",
          "K252600",
          "K112509",
          "K053408",
          "K102201",
          "K132226",
          "K082807",
          "K143061",
          "K130614",
          "K770128",
          "K002361",
          "K230805",
          "K050657",
          "K094037",
          "K110320",
          "K120359",
          "K063166",
          "K182179",
          "K161292",
          "K241815",
          "K213108",
          "K140372",
          "K150368",
          "K120802",
          "K040112",
          "K920738",
          "K230141",
          "K052624",
          "K982553",
          "K091493",
          "K041461",
          "K140098",
          "K180239",
          "K120854",
          "K131186",
          "K141478",
          "K200701",
          "K180213",
          "K262032",
          "K201677",
          "K931684",
          "K063410",
          "K111008",
          "K011170",
          "K141517",
          "K833865",
          "K021164",
          "K212782",
          "K972219",
          "K981789",
          "K800806",
          "K811244",
          "K141417",
          "K022515",
          "K170518",
          "K043263",
          "K081106",
          "K261351",
          "K042766",
          "K170214",
          "K090975",
          "K211650",
          "K141301",
          "K093163",
          "K241128",
          "K254054",
          "K945139",
          "K151442",
          "K233816",
          "K140607",
          "K261406",
          "K131552",
          "K132898",
          "K243995",
          "K073375",
          "K210408",
          "K171372",
          "K201321",
          "K101056",
          "K141493",
          "K022255",
          "K232144",
          "K253906",
          "K905595",
          "K091644",
          "K051908",
          "K254093",
          "K191535",
          "K050101",
          "K152732",
          "K121494",
          "K090047",
          "K171808",
          "K131722",
          "K991763",
          "K131670",
          "K120016",
          "K040777",
          "K191118",
          "K905774",
          "K090492",
          "K083154",
          "K061940",
          "K242988",
          "K983787",
          "K081373",
          "K093781",
          "K212348",
          "K180736",
          "K221558",
          "K983881",
          "K140876",
          "K102785",
          "K101240",
          "K981715",
          "K213014",
          "K243308",
          "K102597",
          "K120157",
          "K131867",
          "K120717",
          "K240318",
          "K990094",
          "K083694",
          "K240613",
          "K092178",
          "K152976",
          "K231684",
          "K113652",
          "K233873",
          "K092671",
          "K170887",
          "K151886",
          "K072562",
          "K113048",
          "K955729",
          "K992355",
          "K050655",
          "K200062",
          "K885250",
          "K251361",
          "K181009",
          "K150099",
          "K011459",
          "K022323",
          "K131764",
          "K140259",
          "K990596",
          "K032559",
          "K143139",
          "K061384",
          "K221181",
          "K070160",
          "K170124",
          "K140069",
          "K203408",
          "K223762",
          "K143721",
          "K903697",
          "K061917",
          "K921458",
          "K112794",
          "K954963",
          "K222282",
          "K183620",
          "K946165",
          "K042377",
          "K152142",
          "K151057",
          "K261830",
          "K040022",
          "K231292",
          "K120108",
          "K964362",
          "K150121",
          "K250948",
          "K132554",
          "K241262",
          "K971321",
          "K123525",
          "K111663",
          "K181425",
          "K180310",
          "K042355",
          "K123055",
          "K251945",
          "K102537",
          "K192327",
          "K151235",
          "K031961",
          "K042237",
          "K250988",
          "K233665",
          "K160633",
          "K182466",
          "K243050",
          "K112926",
          "K213214",
          "K170727",
          "K133930",
          "K243368",
          "K212640",
          "K170843",
          "K113733",
          "K200246",
          "K072411",
          "K211695",
          "K110086",
          "K141121",
          "K092015",
          "K131834",
          "K090666",
          "K110271",
          "K093433",
          "K153716",
          "K210198",
          "K232115",
          "K120772",
          "K003235",
          "K231262",
          "K113339",
          "K192297",
          "K141796",
          "K021321",
          "K131657",
          "K101930",
          "K121425",
          "K082078",
          "K193554",
          "K051747",
          "K252959",
          "K915818",
          "K123918",
          "K260069",
          "K161037",
          "K122310",
          "K992961",
          "K130061",
          "K222465",
          "K222624",
          "K243963",
          "K001945",
          "K944856",
          "K960988",
          "K993510",
          "K220199",
          "K914998",
          "K222244",
          "K893201",
          "K161746",
          "K143138",
          "K133536",
          "K152062",
          "K192984",
          "K001941",
          "K933112",
          "K062747",
          "K241282",
          "K123403",
          "K201235",
          "K113014",
          "K073228",
          "K063020",
          "K002710",
          "K801603",
          "K161590",
          "K993465",
          "K973812",
          "K203511",
          "K152974",
          "K934614",
          "K022139",
          "K152306",
          "K212334",
          "K061973",
          "K183011",
          "K213712",
          "K242486",
          "K063506",
          "K250935",
          "K251135",
          "K183172",
          "K002184",
          "K162179",
          "K163361",
          "K113405",
          "K132591",
          "K962616",
          "K093900",
          "K020611",
          "K170310",
          "K013248",
          "K123875",
          "K043227",
          "K022324",
          "K163007",
          "K153340",
          "K112085",
          "K800502",
          "K973438",
          "K873005",
          "K132502",
          "K161747",
          "K123562",
          "K113318",
          "K003788",
          "K241995",
          "K102282",
          "K161913",
          "K203474",
          "K261145",
          "K191326",
          "K222267",
          "K150649",
          "K092247",
          "K063033",
          "K032269",
          "K253300",
          "K181806",
          "K080992",
          "K193452",
          "K221360",
          "K843370",
          "K123203",
          "K202971",
          "K220136",
          "K142418",
          "K093950",
          "K200762",
          "K090440",
          "K210750",
          "K221920",
          "K122737",
          "K981775",
          "K111620",
          "K942359",
          "K132769",
          "K912932",
          "K240181",
          "K252191",
          "K122936",
          "K150009",
          "K213864",
          "K250494",
          "K151277",
          "K232105",
          "K140617",
          "K061012",
          "K191972",
          "K131445",
          "K242973",
          "K260411",
          "K090692",
          "K202912",
          "K252807",
          "K112798",
          "K050646",
          "K162307",
          "K201510",
          "K083843",
          "K070823",
          "K232394",
          "K903252",
          "K172262",
          "K060156",
          "K141735",
          "K083025",
          "K912936",
          "K100776",
          "K060969",
          "K130116",
          "K241218",
          "K112689",
          "K260054",
          "K923861",
          "K870388",
          "K072740",
          "K121601",
          "K160002",
          "K063875",
          "K173121",
          "K062903",
          "K232829",
          "K102429",
          "K260090",
          "K110959",
          "K260277",
          "K240388",
          "K931244",
          "K030881",
          "K974603",
          "K113718",
          "K140892",
          "K200043",
          "K152253",
          "K191711",
          "K961497",
          "K210157",
          "K250865",
          "K261038",
          "K031334",
          "K120409",
          "K261054",
          "K201917",
          "K242554",
          "K132642",
          "K231257",
          "K102845",
          "K180150",
          "K100475",
          "K860591",
          "K171904",
          "K222665",
          "K983988",
          "K141823",
          "K120360",
          "K234059",
          "K242814",
          "K162635",
          "K071577",
          "K961496",
          "K190409",
          "K910957",
          "K221362",
          "K141677",
          "K882454",
          "K212608",
          "K171590",
          "K240703",
          "K241296",
          "K133616",
          "K073535",
          "K220463",
          "K243610",
          "K082625",
          "K173930",
          "K140376",
          "K131566",
          "K063672",
          "K040593",
          "K011354",
          "K171690",
          "K013415",
          "K161448",
          "K231887",
          "K132296",
          "K212378",
          "K031178",
          "K073460",
          "K860600",
          "K254053",
          "K140622",
          "K071325",
          "K071105",
          "K031677",
          "K040908",
          "K252949",
          "K242079",
          "K182783",
          "K140565",
          "K143717",
          "K172886",
          "K011237",
          "K081759",
          "K042695",
          "K053182",
          "K213489",
          "K141204",
          "K202959",
          "K110908",
          "K030597",
          "K030310",
          "K200834",
          "K242998",
          "K113602",
          "K032032",
          "K152312",
          "K201132",
          "K223342",
          "K232652",
          "K052677",
          "K060798",
          "K212433",
          "K191848",
          "K130731",
          "K140216",
          "K093914",
          "K072423",
          "K142306",
          "K051986",
          "K220937",
          "K162507",
          "K853709",
          "K970503",
          "K931689",
          "K011139",
          "K122334",
          "K090839",
          "K192592",
          "K253916",
          "K140397",
          "K133939",
          "K173293",
          "K131474",
          "K073432",
          "K142121",
          "K192473",
          "K020401",
          "K133691",
          "K961719",
          "K093928",
          "K001311",
          "K122308",
          "K080295",
          "K052683",
          "K061955",
          "K242055",
          "K210534",
          "K141241",
          "K252997",
          "K182991",
          "K250933",
          "K071798",
          "K962894",
          "K990481",
          "K250923",
          "K230527",
          "K123964",
          "K101400",
          "K071184",
          "K161864",
          "K131360",
          "K192504",
          "K012655",
          "K240958",
          "K162439",
          "K032413",
          "K153379",
          "K110125",
          "K201728",
          "K060294",
          "K130774",
          "K192356",
          "K090675",
          "K143331",
          "K143025",
          "K071809",
          "K063275",
          "K170979",
          "K083286",
          "K111326",
          "K111432",
          "K241387",
          "K172300",
          "K111041",
          "K994061",
          "K212297",
          "K181843",
          "K261511",
          "K210205",
          "K161048",
          "K974030",
          "K131132",
          "K110176",
          "K122538",
          "K162841",
          "K072083",
          "K201527",
          "K261191",
          "K052538",
          "K103513",
          "K040907",
          "K013775",
          "K203002",
          "K090877",
          "K241539",
          "K190253",
          "K211324",
          "K112406",
          "K972196",
          "K011118",
          "K013657",
          "K140107",
          "K202803",
          "K230971",
          "K163293",
          "K161041",
          "K160300",
          "K090522",
          "K250952",
          "K061753",
          "K063709",
          "K070169",
          "K171173",
          "K190953",
          "K091058",
          "K203414",
          "K061400",
          "K782123",
          "K020819",
          "K100271",
          "K073624",
          "K221809",
          "K113648",
          "K080522",
          "K234031",
          "K191793",
          "K150675",
          "K033669",
          "K972323",
          "K023879",
          "K201959",
          "K173166",
          "K943853",
          "K803176",
          "K141680",
          "K032187",
          "K982483",
          "K943986",
          "K090053",
          "K140119",
          "K241709",
          "K091156",
          "K241754",
          "K083447",
          "K260761",
          "K081623",
          "K890939",
          "K212979",
          "K935448",
          "K982732",
          "K963700",
          "K021458",
          "K143749",
          "K050512",
          "K963325",
          "K252356",
          "K260323",
          "K153034",
          "K120689",
          "K143002",
          "K141045",
          "K233967",
          "K120903",
          "K011460",
          "K243999",
          "K260958",
          "K022230",
          "K251732",
          "K250498",
          "K023007",
          "K242399",
          "K140226",
          "K102095",
          "K033756",
          "K181091",
          "K160191",
          "K242751",
          "K172260",
          "K142836",
          "K193345",
          "K955472",
          "K050462",
          "K141905",
          "K151716",
          "K925500",
          "K161696",
          "K093761",
          "K251132",
          "K254249",
          "K170401",
          "K182818",
          "K100676",
          "K213059",
          "K172425",
          "K133437",
          "K211646",
          "K091609",
          "K223150",
          "K213837",
          "K914804",
          "K850401",
          "K070592",
          "K892228",
          "K142419",
          "K133974",
          "K230623",
          "K151178",
          "K930592",
          "K222397",
          "K062498",
          "K973982",
          "K173746",
          "K133675",
          "K062494",
          "K110670",
          "K030198",
          "K081588",
          "K213005",
          "K120667",
          "K112560",
          "K253178",
          "K242596",
          "K990392",
          "K041601",
          "K810061",
          "K070793",
          "K012114",
          "K100604",
          "K143697",
          "K170705",
          "K974017",
          "K143023",
          "K052614",
          "K201149",
          "K242445",
          "K202496",
          "K190391",
          "K212841",
          "K210016",
          "K202889",
          "K050852",
          "K151879",
          "K210290",
          "K240487",
          "K913930",
          "K141232",
          "K153207",
          "K081353",
          "K981283",
          "K193633",
          "K161665",
          "K931688",
          "K120015",
          "K972420",
          "K101962",
          "K073186",
          "K170313",
          "K133541",
          "K953714",
          "K123347",
          "K103332",
          "K173767",
          "K251161",
          "K243469",
          "K212545",
          "K103408",
          "K200398",
          "K040598",
          "K121651",
          "K083213",
          "K243761",
          "K130009",
          "K063049",
          "K201962",
          "K250892",
          "K160995",
          "K971297",
          "K233919",
          "K181820",
          "K113364",
          "K050121",
          "K151769",
          "K092493",
          "K160177",
          "K222194",
          "K221395",
          "K172350",
          "K140814",
          "K090139",
          "K162078",
          "K102156",
          "K113762",
          "K121452",
          "K113760",
          "K071797",
          "K140508",
          "K181113",
          "K963741",
          "K963798",
          "K153531",
          "K150561",
          "K210837",
          "K070447",
          "K081546",
          "K254162",
          "K961498",
          "K060474",
          "K260390",
          "K043560",
          "K162829",
          "K122860",
          "K072175",
          "K111540",
          "K140769",
          "K142579",
          "K082072",
          "K231623",
          "K133452",
          "K031609",
          "K142581",
          "K033303",
          "K233423",
          "K140357",
          "K202657",
          "K131093",
          "K850444",
          "K131782",
          "K180972",
          "K133840",
          "K191641",
          "K241666",
          "K141784",
          "K201259",
          "K200367",
          "K931694",
          "K254288",
          "K110574",
          "K181035",
          "K213567",
          "K953644",
          "K092889"
        ],
        "registration_number": [
          "3010041430",
          "1057425",
          "8031020",
          "3009971621",
          "3006946279",
          "8010665",
          "3018080016",
          "3013820441",
          "3015440604",
          "1032347",
          "1030489",
          "1835251",
          "1834331",
          "9611281",
          "3004638532",
          "1043534",
          "3005827567",
          "3015869121",
          "2183946",
          "3010329663",
          "3011530718",
          "3015231789",
          "1835444",
          "3021349259",
          "3004369035",
          "2029447",
          "3009189869",
          "1000461041",
          "3005706667",
          "3003249380",
          "9610622",
          "3009882462",
          "3008102042",
          "2244478",
          "3030691054",
          "3016261131",
          "3006179046",
          "2183650",
          "1424434",
          "3002907620",
          "3010726901",
          "3034676720",
          "3003935342",
          "3004976965",
          "3009756327",
          "3034532468",
          "3017980266",
          "2242056",
          "3013540005",
          "1833920",
          "3005562917",
          "3009153862",
          "3005751028",
          "9680825",
          "3014937101",
          "3009513193",
          "3013561205",
          "3005004799",
          "3033509898",
          "3010606097",
          "8043862",
          "3023808054",
          "3000170817",
          "9611390",
          "2531477",
          "3025603301",
          "3008747271",
          "3009973699",
          "3011623994",
          "3003541440",
          "3010047402",
          "3014314623",
          "3007143290",
          "3021010222",
          "1818910",
          "8010099",
          "1833986",
          "3015974593",
          "3008658204",
          "3008599979",
          "1221051",
          "9611112",
          "3015869493",
          "9610612",
          "3008868758",
          "3012329926",
          "3013365802",
          "1835296",
          "3016050940",
          "3016844398",
          "3019269298",
          "3014257776",
          "3027760323",
          "3010097171",
          "3008262715",
          "3013843230",
          "3015131017",
          "3008337808",
          "1048735",
          "3013011598",
          "1417592",
          "3002807310",
          "9616944",
          "3019455",
          "3011656326",
          "1935627",
          "3007993775",
          "3014170143",
          "3012447612",
          "8043792",
          "2183449",
          "1649518",
          "2027148",
          "9610726",
          "9612277",
          "2133928",
          "3027339877",
          "1721676",
          "3023852420",
          "3008749819",
          "3012725451",
          "3024813436",
          "3030183061",
          "3030412764",
          "3009941480",
          "3009882675",
          "3031240334",
          "3009656988",
          "2249529",
          "3038776593",
          "3007738812",
          "3017191784",
          "3022777867",
          "3010673777",
          "3036042032",
          "3014315669",
          "3013767421",
          "1834379",
          "3009196021",
          "3015356625",
          "1220477",
          "3006395932",
          "3012491394",
          "3000270450",
          "3012478585",
          "3035785605",
          "3016247852",
          "3011302692",
          "3011500362",
          "1226425",
          "3011170410",
          "3005290844",
          "3014315560",
          "2134285",
          "3011683674",
          "3008696586",
          "3025141",
          "3029933740",
          "3015876273",
          "3012470322",
          "3006849754",
          "3010120326",
          "3010509633",
          "3004217743",
          "3009732568",
          "3015075784",
          "1822565",
          "1720929",
          "3009998573",
          "3015882686",
          "3010178296",
          "3006791286",
          "3010370500",
          "3019807891",
          "3044753263",
          "3009540749",
          "8010468",
          "3004049923",
          "9613910",
          "1824199",
          "3021635140",
          "3003761012",
          "1424263",
          "3008534770",
          "3011015572",
          "1060840",
          "3010123256",
          "3005061536",
          "3021336182",
          "1527105",
          "3011354099",
          "3027242374",
          "1722511",
          "9613350",
          "1526534",
          "3008114965",
          "3010155648",
          "3010462278",
          "3007791110",
          "3016084569",
          "1421101",
          "9615766",
          "3022159082",
          "3010162973",
          "3012086398",
          "3017209758",
          "3015531529",
          "3013086329",
          "3014763043",
          "1038671",
          "3008791302",
          "3015806723",
          "9610921",
          "9680619",
          "3022142628",
          "3007923096",
          "2953359",
          "3030714745",
          "3014655115",
          "3013700547",
          "3010470577",
          "3010331645",
          "1932180",
          "3019923333",
          "2183785",
          "3016112537",
          "1649390",
          "1057946",
          "3043026734",
          "3019767615",
          "2183967",
          "3017609305",
          "3006001176",
          "9615128",
          "3008559295",
          "2029275",
          "3010389204",
          "3017528621",
          "3003525643",
          "2530808",
          "3011388423",
          "3014162916",
          "1528646",
          "1828288",
          "3007289093",
          "3007334927",
          "3015869492",
          "3008396464",
          "8030965",
          "9615800",
          "3006513362",
          "3014128887",
          "3007109793",
          "3015542154",
          "3010120104",
          "3014262693",
          "3004142400",
          "9616680",
          "1226544",
          "2245304",
          "3010363503",
          "3010287687",
          "3004549189",
          "9611813",
          "2028632",
          "3005641619",
          "1319429",
          "3009144915",
          "3014273424",
          "1058584",
          "3010502940",
          "3012818475",
          "3007125392",
          "1054811",
          "1020279",
          "3026311512",
          "3032588003",
          "3010863450",
          "2032098",
          "3007913880",
          "3006742481",
          "3008262872",
          "3009887475",
          "3010057495",
          "3031261833",
          "3004188066",
          "3008650117",
          "3009201148",
          "3010287737",
          "3013194153",
          "3009959868",
          "3014483751",
          "3009973336",
          "3013413393",
          "3008793310",
          "3015399803",
          "3024890263",
          "3004993707",
          "3007539489",
          "3006801247",
          "3014967149",
          "3003477135",
          "3006460162",
          "3009417901",
          "3009158523",
          "3026035863",
          "3010846112",
          "3007648354",
          "3006801265",
          "3013302242",
          "3014527928",
          "3017565094",
          "3012329552",
          "3015230955",
          "3030926959",
          "3014967969",
          "3005497913",
          "3015207155",
          "3010173425",
          "1833824",
          "3001239363",
          "3010120339",
          "3016237080",
          "3020584246",
          "1218017",
          "3010068573",
          "1643264",
          "3005874553",
          "3007051929",
          "3010120135",
          "3015410662",
          "3011301313",
          "1835831",
          "3010673850",
          "3013055499",
          "8031010",
          "3000327445",
          "1313525",
          "8010177",
          "3008812560",
          "3015780293",
          "3003236702",
          "3008285983",
          "3010118938",
          "3009996260",
          "3004154314",
          "3017435639",
          "3002962587",
          "3006694268",
          "3010440433",
          "9611579",
          "2532027",
          "3004187715",
          "3004491689",
          "3015877656",
          "3004983210",
          "3004635447",
          "3010303097",
          "3010032903",
          "1222274",
          "2320767",
          "3010314800",
          "3014129047",
          "3011127597",
          "3010123206",
          "9680515",
          "3011569539",
          "3013756169",
          "3016851379",
          "8010944",
          "3016727307",
          "1833506",
          "3013843055",
          "1225838",
          "9614438",
          "3006981798",
          "3008236846",
          "3007113169",
          "9611274",
          "2027754",
          "3010049501",
          "3007366790",
          "3016438694",
          "1000517406",
          "3016778139",
          "3021393544",
          "3034525",
          "3031800723",
          "3009381600",
          "3026576110",
          "3012966183",
          "3002579136",
          "3015831087",
          "3015212339",
          "3021226419",
          "3011580264",
          "3010047454",
          "3017980495",
          "3023265483",
          "2134947",
          "3013176080",
          "9681642",
          "3036756245",
          "1835572",
          "2134470",
          "3014680795",
          "9613369",
          "3002993234",
          "1220246",
          "3002808145",
          "3018077525",
          "3043543260",
          "1061927",
          "3015946784",
          "3012275107",
          "3008951116",
          "1221053",
          "3006498370",
          "2648920",
          "2648666",
          "9710629",
          "3017521423",
          "1319660",
          "3004513872",
          "3020704423",
          "3010039400",
          "1051526",
          "3011137372",
          "3006017180",
          "3016759112",
          "3010362364",
          "8010257",
          "3010158639",
          "3007420745",
          "3009888740",
          "3004748528",
          "3012131184",
          "2032830",
          "3007441485",
          "3003322138",
          "3004371426",
          "3004464325",
          "3008556682",
          "3014833750",
          "3006217744",
          "3011230048",
          "3014302784",
          "3035366890",
          "3010400367",
          "2647346",
          "3014004349",
          "1450662",
          "3038503932",
          "3009812190",
          "2024024",
          "3013014058",
          "3043620689",
          "3033519208",
          "3010667733",
          "3004941535",
          "3011296511",
          "3009662565",
          "3002949614",
          "3009826895",
          "1423662",
          "2031009",
          "1526711",
          "1058084",
          "3010041499",
          "3038503572",
          "3009760038",
          "3006272282",
          "3004153896",
          "3006783837",
          "3012755988",
          "3010041511",
          "9610905",
          "3011567699",
          "9710312",
          "1836357",
          "1043653",
          "2030624",
          "3009532798",
          "3005983700",
          "3010375065",
          "3009116370",
          "2249615",
          "3006639944",
          "3009923578",
          "3003661942",
          "3008812251",
          "9681465",
          "9611278",
          "3009423112",
          "3021008900",
          "3013280419",
          "3018094310",
          "3009973505",
          "3011295718",
          "2249697",
          "3008572101",
          "3016655171",
          "3006128100",
          "1224360",
          "1828464",
          "1531050",
          "3004499989",
          "1825034",
          "3010052483",
          "3011187779",
          "3006487372",
          "1526439",
          "2028523",
          "3010123172",
          "3010009693",
          "3002807295",
          "3010197224",
          "3013846070",
          "2011171"
        ],
        "fei_number": [
          "3019827409",
          "1000395711",
          "3000210784",
          "1000115656",
          "3010041430",
          "3009971621",
          "3006946279",
          "1000522098",
          "3018080016",
          "3013820441",
          "3015440604",
          "1032347",
          "1000221916",
          "3004638532",
          "1043534",
          "3005827567",
          "3015869121",
          "1000139987",
          "3002807172",
          "1000221981",
          "3010329663",
          "3011530718",
          "3015231789",
          "3021349259",
          "3004369035",
          "3009189869",
          "1000461041",
          "3005706667",
          "1000125930",
          "3003249380",
          "1000514086",
          "3009882462",
          "1000185904",
          "3030691054",
          "3016261131",
          "3006179046",
          "2183650",
          "3002907620",
          "1000115735",
          "3002821504",
          "3010726901",
          "1000119305",
          "1000125147",
          "3034676720",
          "3000717687",
          "3003935342",
          "3004976965",
          "1000477302",
          "3001644153",
          "3034532468",
          "3017980266",
          "2242056",
          "3013540005",
          "3003018882",
          "3005562917",
          "3009153862",
          "3005751028",
          "1000136451",
          "3014937101",
          "3003356728",
          "3009513193",
          "3013561205",
          "3005004799",
          "3005747797",
          "3022270316",
          "3033509898",
          "3010606097",
          "3023808054",
          "3000170817",
          "3025603301",
          "3008747271",
          "3009973699",
          "3011623994",
          "3003541440",
          "3010047402",
          "3014314623",
          "3007143290",
          "3021010222",
          "3002904345",
          "1818910",
          "3015974593",
          "3002806577",
          "3008658204",
          "3008599979",
          "1221051",
          "3015869493",
          "3008868758",
          "3012329926",
          "3002808264",
          "3013365802",
          "3016050940",
          "3016844398",
          "3002807305",
          "3019269298",
          "3014257776",
          "3027760323",
          "3010097171",
          "3008262715",
          "3002786339",
          "3013843230",
          "3015131017",
          "3008337808",
          "1048735",
          "3003051987",
          "3013011598",
          "1417592",
          "3002807310",
          "3019455",
          "3011656326",
          "1000120314",
          "1935627",
          "1832656",
          "3007993775",
          "3014170143",
          "3003058448",
          "3012447612",
          "2183449",
          "1000132037",
          "2027148",
          "3009256700",
          "3002808269",
          "3027339877",
          "1721676",
          "3023852420",
          "3008749819",
          "3012725451",
          "3024813436",
          "3030183061",
          "3030412764",
          "3009941480",
          "3002807395",
          "3002806773",
          "3031240334",
          "3009656988",
          "3003407235",
          "3002808293",
          "3038776593",
          "3007738812",
          "3017191784",
          "3022777867",
          "3010673777",
          "3036042032",
          "3014315669",
          "3013767421",
          "1000306340",
          "3001814066",
          "3002807038",
          "3009196021",
          "3015356625",
          "1220477",
          "1000405819",
          "3006395932",
          "3012491394",
          "3000270450",
          "3012478585",
          "3035785605",
          "3016247852",
          "3011302692",
          "3011500362",
          "3011170410",
          "1000306431",
          "3005290844",
          "3014315560",
          "3011683674",
          "3008696586",
          "3029933740",
          "3015876273",
          "3012470322",
          "3006849754",
          "3010120326",
          "3010509633",
          "3004217743",
          "3002795782",
          "3009732568",
          "3015075784",
          "1720929",
          "3009998573",
          "3015882686",
          "1000220733",
          "3006791286",
          "3010370500",
          "3019807891",
          "3044753263",
          "3009540749",
          "3004049923",
          "1824199",
          "3021635140",
          "3003761012",
          "3008534770",
          "3000206435",
          "3011015572",
          "3010123256",
          "3005061536",
          "3009322142",
          "3021336182",
          "3027242374",
          "3011354099",
          "1000219637",
          "1526534",
          "3008114965",
          "3010155648",
          "3010462278",
          "3007791110",
          "3001452082",
          "3002924544",
          "3016084569",
          "1421101",
          "3022159082",
          "3012086398",
          "3003128516",
          "3017209758",
          "3015531529",
          "3013086329",
          "3014763043",
          "1038671",
          "3008791302",
          "3015806723",
          "3022142628",
          "3007923096",
          "3030714745",
          "3014655115",
          "3001642380",
          "3013700547",
          "3010470577",
          "3010331645",
          "1317628",
          "3019923333",
          "3002808043",
          "3016112537",
          "2183785",
          "3002807041",
          "3043026734",
          "3019767615",
          "3017609305",
          "3006001176",
          "3008559295",
          "3008820440",
          "3010389204",
          "3017528621",
          "3003525643",
          "3002806315",
          "3001406084",
          "3011388423",
          "3014162916",
          "3007289093",
          "1828288",
          "3007334927",
          "3015869492",
          "1000114185",
          "3002806685",
          "3008396464",
          "1000136478",
          "3001026312",
          "1000115331",
          "3006513362",
          "3014128887",
          "3007109793",
          "3015542154",
          "3010120104",
          "3014262693",
          "3004142400",
          "3003414678",
          "2245304",
          "3010363503",
          "3010287687",
          "3002459190",
          "3005641619",
          "3009144915",
          "3014273424",
          "3010502940",
          "4498",
          "3005233524",
          "3012818475",
          "3000215205",
          "3007125392",
          "1020279",
          "3002807328",
          "3026311512",
          "3002807036",
          "3010863450",
          "3032588003",
          "3007913880",
          "3006742481",
          "3008262872",
          "3009887475",
          "3010057495",
          "3031261833",
          "3004188066",
          "3008650117",
          "3009201148",
          "3010287737",
          "3008782585",
          "3013194153",
          "3009959868",
          "3014483751",
          "3009973336",
          "3003015552",
          "3013413393",
          "3002807464",
          "3008793310",
          "3015399803",
          "3024890263",
          "3004993707",
          "3007539489",
          "3002807231",
          "3006801247",
          "3014967149",
          "3000203000",
          "3003477135",
          "3006460162",
          "3009417901",
          "3009158523",
          "3026035863",
          "3010846112",
          "3007648354",
          "3006801265",
          "3013302242",
          "3008647423",
          "3003386935",
          "1000121057",
          "3014527928",
          "3017565094",
          "3012329552",
          "3015230955",
          "3030926959",
          "3014967969",
          "3005497913",
          "3002594206",
          "3010938185",
          "3015207155",
          "3001239363",
          "3010120339",
          "3016237080",
          "3020584246",
          "1218017",
          "3010068573",
          "3002755653",
          "1643264",
          "3005874553",
          "3007051929",
          "3010120135",
          "3002462840",
          "3015410662",
          "1000136269",
          "3011301313",
          "3010673850",
          "3002807827",
          "3013055499",
          "3001236277",
          "3000327445",
          "3008812560",
          "3015780293",
          "3003236702",
          "3008285983",
          "3010118938",
          "3009996260",
          "3004154314",
          "3017435639",
          "3002962587",
          "1000069183",
          "3006694268",
          "3010440433",
          "3000718467",
          "3002807893",
          "3004187715",
          "3004491689",
          "3015877656",
          "3004983210",
          "3004635447",
          "3010303097",
          "3010032903",
          "3003292403",
          "3010314800",
          "3011127597",
          "3004574120",
          "3010123206",
          "3000205819",
          "3011569539",
          "3013756169",
          "3016851379",
          "3016727307",
          "3013843055",
          "3006981798",
          "3010871687",
          "1000525271",
          "3008236846",
          "3007113169",
          "2027754",
          "3000205591",
          "3010049501",
          "3016438694",
          "1000517406",
          "3016778139",
          "3021393544",
          "3007282753",
          "3031800723",
          "3009381600",
          "3026576110",
          "3012966183",
          "3002579136",
          "3015831087",
          "3015212339",
          "3021226419",
          "3011580264",
          "3010047454",
          "3017980495",
          "3023265483",
          "3013176080",
          "3036756245",
          "3014680795",
          "3003064967",
          "3002993234",
          "1220246",
          "3002808145",
          "3018077525",
          "3043543260",
          "3015946784",
          "3012275107",
          "3008951116",
          "1221053",
          "3006498370",
          "5870",
          "2648666",
          "3017521423",
          "3004513872",
          "3020704423",
          "3010039400",
          "1051526",
          "3006017180",
          "3016759112",
          "3010362364",
          "3010158639",
          "3007420745",
          "3009888740",
          "3004748528",
          "3012131184",
          "3007441485",
          "3003322138",
          "3004464325",
          "3002807830",
          "3008556682",
          "3005969827",
          "3014833750",
          "3006217744",
          "1000125025",
          "3011230048",
          "3014302784",
          "3002807113",
          "3035366890",
          "3010400367",
          "2647346",
          "3014004349",
          "1000306303",
          "1450662",
          "3038503932",
          "2024024",
          "3001049282",
          "3013014058",
          "3003056094",
          "3043620689",
          "3010667733",
          "3033519208",
          "1000116116",
          "3004941535",
          "3011296511",
          "3009662565",
          "3002949614",
          "3002806545",
          "3009826895",
          "1526711",
          "3003690049",
          "3038503572",
          "3009760038",
          "3006272282",
          "3004153896",
          "3012755988",
          "3010041511",
          "3011567699",
          "3000717902",
          "1043653",
          "3009532798",
          "1000143502",
          "3005983700",
          "3010375065",
          "3009116370",
          "3006639944",
          "3009923578",
          "3003661942",
          "3003070421",
          "3004051158",
          "3002806724",
          "3009423112",
          "3021008900",
          "3013280419",
          "3018094310",
          "3000215273",
          "3009973505",
          "3011295718",
          "1000518793",
          "3008572101",
          "3016655171",
          "3006128100",
          "1828464",
          "3004499989",
          "1825034",
          "3010052483",
          "3002287318",
          "3011187779",
          "3006487372",
          "3003110073",
          "3004167986",
          "1526439",
          "3010123172",
          "3010009693",
          "3002807295",
          "3010197224",
          "3013846070",
          "2011171",
          "3001236812"
        ],
        "device_name": "Plate, Fixation, Bone",
        "medical_specialty_description": "Orthopedic",
        "regulation_number": "888.3030",
        "device_class": "2"
      }
    }
  ]
}