  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-10-22",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "152635",
      "product_res_number": "Z-1502-2017",
      "event_date_initiated": "2016-11-18",
      "event_date_created": "2017-03-20",
      "recall_status": "Terminated",
      "event_date_terminated": "2018-07-13",
      "res_event_number": "76283",
      "product_code": "FMZ",
      "k_numbers": [
        "K010222"
      ],
      "product_description": "Giraffe Incubator\nThe Giraffe Incubator is an infant incubator. Incubators provide heat in a controlled manner to neonates who are unable to thermo-regulate based on their own physiology. Incubators provide an enclosed temperature controlled environment",
      "code_info": "See Attached Spreadsheat",
      "firm_fei_number": "1121732",
      "recalling_firm": "Ohmeda Medical",
      "address_1": "8880 Gorman Rd",
      "city": "Laurel",
      "state": "MD",
      "postal_code": "20723-5800",
      "additional_info_contact": "410-888-5376",
      "reason_for_recall": "Certain power cords could overheat. The affected power cords were manufactured by Electric-Cord and are referred to as Taller Bridge power cords. The overheating of the power cord could result in fire, charring, smoke, or sparking where the power cord connects to the wall outlet which could cause thermal injury.",
      "root_cause_description": "Under Investigation by firm",
      "action": "According to the firm, this issue will be resolved by sending an Urgent Medical Device Correction customer letter to customers with affected Power Cords. This letter will inform the customer of the issue and provide safety instructions for immediate mitigation of the issue. The long-term solution is to re-place all affected Power Cords at no cost to the customer.\n\nAccording to the firm, the plan for public notification is to contact all customers with affected Power Cords by means of an Urgent Medical Device Correction letter. In the US this will be sent by a traceable means (either US Postal Service with receipt acknowledgement (registered mail) or equivalent courier service such as FEDEX). This letter will be sent to the following titles within the affected accounts; Nurse Managers, Labor & Delivery/NICU,  Bio-Medical Engineering Department Managers and Risk Management Directors\n\nWe will track all service requests for the field action to completion. These service requests will record the replacement of the affected Power Cords. Exceptions to completion of the service request will be recorded as well. Records of field action completion will be retained per our processes and procedures.",
      "product_quantity": "5,993 (5,080 US; 913 OUS)",
      "distribution_pattern": "Worldwide Distribution - US (nationwide and Puerto Rico) Bahamas and Internationally to UK, Trinidad & Tobago, Taiwan, Spain, Panama, Netherlands Antilles, Mexico, Lebanon, Japan, Ireland, Honduras, El Salvador, Ecuador, Costa Rica, Colombia, Canada, Brazil, and Venezuela,",
      "openfda": {
        "k_number": [
          "K001242",
          "K072512",
          "K922618",
          "K870223",
          "K840526",
          "K040910",
          "K821896",
          "K993407",
          "K870222",
          "K810792",
          "K101788",
          "K901585",
          "K152809",
          "K924297",
          "K890476",
          "K243437",
          "K182859",
          "K914864",
          "K172154",
          "K031387",
          "K020547",
          "K781876",
          "K900735",
          "K913154",
          "K915752",
          "K912909",
          "K954204",
          "K071977",
          "K960980",
          "K010222",
          "K884086",
          "K260326",
          "K895550",
          "K912910",
          "K920049",
          "K913291",
          "K021809",
          "K251619",
          "K802640",
          "K871399",
          "K943360",
          "K132543",
          "K101778",
          "K822656",
          "K071175",
          "K802639",
          "K070291",
          "K213553",
          "K901157",
          "K003067",
          "K912000",
          "K061856",
          "K974349",
          "K802126",
          "K040068",
          "K190494",
          "K053399",
          "K903378",
          "K924170",
          "K810067",
          "K914134",
          "K801461",
          "K980886",
          "K813238",
          "K940975",
          "K813239",
          "K061280",
          "K900752",
          "K913394",
          "K020543",
          "K102710",
          "K993051",
          "K881476",
          "K152814",
          "K162821",
          "K924324",
          "K993712",
          "K780472",
          "K251663",
          "K182977",
          "K962806",
          "K895782",
          "K914487",
          "K832418",
          "K102279",
          "K102226"
        ],
        "registration_number": [
          "3007734888",
          "9613793",
          "3008729547",
          "3036470679",
          "3014220748",
          "3009077524",
          "1034876",
          "9710602",
          "3006179052",
          "3005934741",
          "1043214",
          "9611500",
          "3049808762",
          "3030089838",
          "3030733800",
          "2510954",
          "1000122786",
          "3005652389",
          "1066270",
          "1226711",
          "1054241",
          "3021559257",
          "1055236",
          "1054713",
          "3012348048"
        ],
        "fei_number": [
          "1000112877",
          "3007734888",
          "3008729547",
          "3006469671",
          "3001104093",
          "3036470679",
          "3014220748",
          "3009077524",
          "1034876",
          "3006179052",
          "3003513129",
          "3005934741",
          "1043214",
          "1000112968",
          "3049808762",
          "3030089838",
          "3030733800",
          "3003338236",
          "2510954",
          "1000122786",
          "1000114111",
          "3021559257",
          "3004846435",
          "3012348048",
          "3000957797"
        ],
        "device_name": "Incubator, Neonatal",
        "medical_specialty_description": "General Hospital",
        "regulation_number": "880.5400",
        "device_class": "2"
      }
    }
  ]
}