      "cfres_id": "217501",
      "product_res_number": "Z-1232-2026",
      "event_date_initiated": "2025-11-07",
      "event_date_posted": "2026-02-02",
      "recall_status": "Open, Classified",
      "res_event_number": "98050",
      "product_code": "NAY",
      "k_numbers": [
        "K131861",
        "K171294",
        "K232610"
      ],
      "product_description": "Brand Name: Da Vinci\nProduct Name: da Vinci X,  Xi Surgical System, & da Vinci 5 Surgical System\nModel/Catalog Number: IS4000; IS4200; IS5000\nSoftware Version: N/A\nProduct Description: The da Vinci Xi, X, and da Vinci 5 surgical systems each consist of three main components: the Surgeon Console (SC), the Vision Cart (VC), and the Patient Cart (PC). The PC is the operative component of the system, and its primary function is to support the instrument arms and camera arm. Each system have four Universal Surgical Manipulators (USMs) also known as arms, which allow the surgeon to control up to three instruments and an endoscope simultaneously to perform surgical tasks (e.g. cutting, suturing, tissue approximation) in a variety of procedures. As the surgeon moves the hand controls within the console, the PC moves the robotic instruments within the patient in a corresponding manner. The da Vinci system and its software are designed such that instruments motion precisely tracks the motion inputs from the hand controls during surgery.\nComponent: The affected part based on this recall, 380647-xx, USM, is a sub component of da Vinci Surgical Instrument",
      "code_info": "Lot Code: UDI: 00886874114216\nFDA Medical Device Listing Number: D531324\nSee attachment  Affected Product List \n\n\nUDI: 00886874114216\nFDA Medical Device Listing Number: D295931\nSee attachment  Affected Product List \n\nUDI: 00886574119747\nFDA Medical Device Listing Number: D531324\nSee attachment  Affected Product List \n\nda Vinci Xi (U.S.)\nUSM Serial Numbers / System Serial Numbers:\n402229\tSK0835\n766250\tSK2180\n797416\tSK3689\n674366\tSK0095\n453952\tSK0135\n10200891\tRSK8057\n675618\tSK3649\n634899\tSK2504\n440133\tSK0682\n362922\tSK6006\n405421\tSK0449\n390728\tSK0389\n608999\tSK2328\n395840\tSK0523\n368190\tSK0837\n441220\tSK0909\n596758\tSK5711\n474567\tSK0075\n376348\tRSK8009\n468435\tSK1448\n586220\tSK5354\n417890\tSK2763\n620604\tSK2121\n454704\tSK1314\n601085\tSK4517\n360714\tSK2497\n502409\tSK0480\n450881\tSK1012\n374877\tSK2478\n614195\tSK1155\n10012820\tSK2135\n685557\tSK2489\n575597\tSK5978\n432486\tSK3140\n624939\tSK4316\n357017\tSK0157\n448370\tSK0959\n432785\tSK1380\n552202\tSK4752\n801777\tSK3600\n598141\tSK1967\n653902\tSK0048\n791279\tSK5269\n392895\tSK0992\n423997\tSK1265\n10130883\tSK5682\n10345574\tSK0756\n609316\tSK0756\n643879\tSK1802\n721374\tSK2851\n721385\tSK2851\n721390\tSK2851\n726207\tSK2851\n423127\tSK0159\n453587\tSK0159\n789074\tSK0159\n803938\tSK3632\n808928\tSK3632\n811477\tSK3632\n405752\tSK0886\n821001\tSK3749\n821012\tSK3749\n821018\tSK3749\n396587\tSK0448\n396835\tSK0448\n396956\tSK0448\n539536\tSK0448\n10201501\tSK2573\n364250\tSK2573\n389078\tSK2573\n10581505\tSK8006\n10591492\tSK8006\n10592026\tSK8006\n10592897\tSK8006\n10397285\tSK7337\n10398002\tSK7337\n10403504\tSK7337\n626074\tSK7337\n682234\tSK2552\n684029\tSK2552\n557855\tSK1374\n558304\tSK1374\n678245\tSK1374\n783025\tSK3579\n803627\tSK3579\n806689\tSK3579\n807816\tSK3579\n10143148\tSK2686\n457566\tSK2686\n673397\tSK2686\n951895\tSK4542\n957596\tSK4542\n959481\tSK4542\n959484\tSK4542\n662812\tSK2351\n662935\tSK2351\n663327\tSK2351\n946051\tSK4628\n972693\tSK4628\n973277\tSK4628\n973278\tSK4628\n785070\tSK3363\n785071\tSK3363\n786266\tSK3363\n448204\tSK0152\n703938\tSK0152\n574265\tSK0159\n592288\tSK1817\n560902\tSK1913\n537160\tSK1913\n459654\tSK1913\n556989\tSK3209\n729789\tSK3209\n731745\tSK3209\n737618\tSK3459\n389462\tSK4178\n845962\tSK4178\n846972\tSK4178\n846947\tSK4178\n10008899\tSK4781\n10010562\tSK4781\n10011023\tSK4781\n10301063\tSK6842\n10305355\tSK6842\n10305783\tSK6842\n10340208\tSK6866\n10340225\tSK6866\n10340569\tSK6866\n10345076\tSK6924\n10345542\tSK6924\n10347613\tSK6924\n10347621\tSK6924\n\nda Vinci Xi (O.U.S.)\n10144327\tSK0241\n885500\tSK4083\n709052\tSK2651\n10002413\tSK4695\n10531698\tCX0067\n441442\tSK0934\n435551\tSK0907\n10241998\tSK6332\n10318042\tSK6759\n10216387\tSK6341\n10217208\tSK6341\n392890\tSK0256\n10216383\tSK6250\n587895\tSK0950\n789071\tSK0777\n450418\tSK0388\n740913\tSK2996\n392885\tSK0129\n464471\tSK1034\n423008\tSK0658\n726556\tSK5869\n443119\tSK0925\n10340582\tSK6917\n10514694\tSK7706\n818737\tSK3669\n819530\tSK3669\n820601\tSK3669\n10060417\tSK5032\n10061285\tSK5032\n10061291\tSK5032\n10061294\tSK5032\n10222556\tSK2052\n421449\tSK2052\n10051344\tSK5104\n10066499\tSK5104\n10068969\tSK5104\n10068971\tSK5104\n10207068\tSK3598\n803631\tSK3598\n810035\tSK3598\n810039\tSK3598\n696805\tSK2661\n700673\tSK2661\n700674\tSK2661\n701164\tSK2661\n753819\tSK3194\n754670\tSK3194\n754675\tSK3194\n712123\tSK4070\n768086\tSK5782\n10186169\tSK3114\n823169\tSK3114\n10160467\tSK3599\n811473\tSK3599\n10205803\tSK6415\n10225737\tSK6415\n10236546\tSK6415\n791775\tSK3494\n791780\tSK3494\n792156\tSK3494\n792565\tSK3494\n691130\tSK2666\n694460\tSK2666\n694487\tSK2666\n694988\tSK2666\n378145\tSK0124\n722261\tSK2839\n724635\tSK2839\n10225711\tSK6630\n10233347\tSK6630\n10233349\tSK6630\n10233962\tSK6630\n646334\tSK2249\n648830\tSK2249\n649482\tSK2249\n10414903\tSK3114\n859539\tSK2649\n\nda Vinci X (O.U.S.)\n364477\tSL0052\n10233342\tSL1118\n392675\tSL0264\n593091\tSL0178\n10168067\tSL0255\n686701\tSL0598\n686724\tSL0598\n689991\tSL0598\n704719\tSL0598\n\n\nda Vinci 5 (U.S.)\nUSM Serial Numbers / System Serial Numbers:\n10651060\tSQ0343\n\nda Vinci 5",
      "firm_fei_number": "3001675293",
      "recalling_firm": "Intuitive Surgical, Inc.",
      "address_1": "1266 Kifer Rd",
      "city": "Sunnyvale",
      "state": "CA",
      "postal_code": "94086-5304",
      "additional_info_contact": "Luis Dominguez Rendon\n408-523-2100",
      "reason_for_recall": "Due to a software implementation error that allowed instruments arms failing an important diagnostic test to remain in clinical use. This test was supposed to be used to detect Universal Surgical Manipulator insertion axis ball screws that exhibit the symptoms of being bent and misaligned which is a precursor to potential ball screw fatigue failure/fraction",
      "root_cause_description": "Process control",
      "action": "On 11/07/2025 and 11/13/2025, the firm emailed \"Urgent Stop Use: Product Safety Notice\" letters to customers informing them to stop use of specific da Vinci Surgical Systems.  In 2022 Intuitive Surgical initiated a field action related to instrument arm ball screw failures. As a result, a field test was implemented to improve detection of affected ball screw.  Intuitive has become aware that this test did not alert the service technicians of pass/fail results.\n\nCustomer are instructed to immediately stop using affected da Vinci Systems. Intuitive will provide a formal follow-up communication, and our representative will contact you to schedule a site visit to perform the necessary corrections. Please distribute this communication to all relevant hospital personnel (e.g., surgeons, OR directors, risk managers, etc.) who use your affected da Vinci Surgical System.\n\nFor Questions, contact Customer Service at:\n\" North and South America: (800) 876-1310, Option 3 (4 am to 5 pm PST) or mail: customerservice@intusurg.com.\n\" Europe, Middle East, Asia and Africa: +800 0821 2020 or +41 21 821 2020 (8 am to 6 pm CET) or eucs@intusurg.com\n\" South Korea: 02-3271-3200 (9 am to 6 pm KSTJ) or support.korea@intusurg.com\n\" Japan: 0120-56-5635 or 03-5575-1362 (9 am to 6 pm JST) or csjapan@intusurg.com\n\" India: +1-800-103-6952 (9 am to 6 pm IT)\n\" Taiwan: +0800-86-8181 (9 am to 6 pm CT)",
      "product_quantity": "219",
      "distribution_pattern": "U.S.: AL, AR, CA, CO, CT, FL, ID, IL, IN, KS, KY, MD, MI, MN, MS, MO, NC, NJ, NV, NY, OH, OK, OR, PA, TN, TX, UT, VA, WA, and WI.\n\nO.U.S.: Austria, Brazil, China, France, Germany, Greece, India, Italy, Japan, Lebanon, Netherlands, South Korea, Spain, Switzerland, Taiwan and United Kingdom",
      "openfda": {
        "k_number": [
          "K030578",
          "K050005",
          "K211784",
          "K101743",
          "K162973",
          "K182371",
          "K192877",
          "K011281",
          "K110451",
          "K110639",
          "K181517",
          "K251202",
          "K151794",
          "K161271",
          "K141075",
          "K180033",
          "K090993",
          "K250674",
          "K214095",
          "K231224",
          "K213710",
          "K211325",
          "K021152",
          "K093217",
          "K261823",
          "K170879",
          "K182140",
          "K251227",
          "K080291",
          "K210918",
          "K063220",
          "K152448",
          "K061260",
          "K173415",
          "K040948",
          "K043153",
          "K240502",
          "K112208",
          "K152421",
          "K171294",
          "K231798",
          "K171947",
          "K242318",
          "K220889",
          "K240852",
          "K072627",
          "K183224",
          "K180351",
          "K243582",
          "K183107",
          "K112263",
          "K200049",
          "K191482",
          "K060391",
          "K220023",
          "K173906",
          "K172643",
          "K040237",
          "K232773",
          "K241638",
          "K170508",
          "K131861",
          "K141077",
          "K011002",
          "K241284",
          "K250442",
          "K222827",
          "K252350",
          "K021036",
          "K050369",
          "K183098",
          "K202166",
          "K173585",
          "K180163",
          "K241814",
          "K202834",
          "K170644",
          "K223080",
          "K183086",
          "K081207",
          "K101581",
          "K254192",
          "K202968",
          "K130266",
          "K253986",
          "K130726",
          "K170641",
          "K191529",
          "K082497",
          "K123840",
          "K152578",
          "K012833",
          "K253556",
          "K142683",
          "K191280",
          "K043288",
          "K161178",
          "K150837",
          "K171120",
          "K143217",
          "K173842",
          "K140553",
          "K240723",
          "K233866",
          "K171699",
          "K212747",
          "K192717",
          "K170875",
          "K131962",
          "K223095",
          "K121921",
          "K170645",
          "K153276",
          "K252675",
          "K173721",
          "K211595",
          "K212054",
          "K251739",
          "K171426",
          "K261824",
          "K251324",
          "K200473",
          "K203632",
          "K120215",
          "K251426",
          "K081137",
          "K170865",
          "K192803",
          "K022574",
          "K171388",
          "K251817",
          "K191736",
          "K230033",
          "K232610",
          "K170713",
          "K113706",
          "K260695",
          "K123329",
          "K070947",
          "K171632",
          "K211997",
          "K143132",
          "K150284",
          "K122532",
          "K152892",
          "K211316",
          "K243641",
          "K250786",
          "K212101",
          "K222839",
          "K243714",
          "K050802",
          "K182421",
          "K002489",
          "K140189",
          "K190999",
          "K162411",
          "K202571",
          "K123463",
          "K173337",
          "K242427",
          "K990144",
          "K042855",
          "K112584",
          "K252069",
          "K251213"
        ],
        "registration_number": [
          "",
          "3004784537",
          "8043903",
          "3007303113",
          "3016096100",
          "3038188839",
          "3016607092",
          "2032112",
          "3009161688",
          "3017820152",
          "8043980",
          "3035387162",
          "3026606306",
          "3013283620",
          "3011390076",
          "1721686",
          "8010456",
          "3036035332",
          "3015224777",
          "2022435",
          "2246552",
          "3013077751",
          "3017119401",
          "3044545674",
          "8010877",
          "1531174",
          "3015612252",
          "3033043422",
          "3038187466",
          "3007487007",
          "3007111496",
          "3010684280",
          "3011063460",
          "3012627460",
          "3017636737",
          "1650907",
          "3015895145",
          "3013665681",
          "3016555232",
          "3009719225",
          "3018126215",
          "3033507886",
          "3014656892",
          "3011459762",
          "1226146",
          "9611665",
          "3001556604",
          "3016079756",
          "3014635169",
          "3014579024",
          "3017619652",
          "3013942591",
          "3016832577",
          "3012811961",
          "3042940623",
          "3020331900",
          "2011171",
          "9614969",
          "9616517",
          "3014644276",
          "3015336263",
          "3014663814",
          "3001592626",
          "2032098",
          "3004111573",
          "3001675293",
          "2029275",
          "1061124",
          "3007029079",
          "3012453745",
          "3010564249",
          "3009217531",
          "3018907196",
          "3015241782",
          "3002259632",
          "3015153469",
          "3013868968",
          "3010493171",
          "3013188547",
          "3003537036",
          "3009941480",
          "3008837339",
          "2029015",
          "3005369776",
          "3010860245",
          "2955842",
          "2936485",
          "3010157088",
          "1058584",
          "3010193531",
          "3003898360",
          "3010432890",
          "3031594238",
          "3008309062",
          "3042953929",
          "9681503",
          "3014309390",
          "3022626486",
          "3010885402"
        ],
        "fei_number": [
          "",
          "3004784537",
          "3007303113",
          "3016096100",
          "3038188839",
          "3003058448",
          "3002477156",
          "3016607092",
          "3009161688",
          "3017820152",
          "3035387162",
          "1000160458",
          "3026606306",
          "3013283620",
          "3011390076",
          "1721686",
          "3036035332",
          "1000306431",
          "3015224777",
          "2022435",
          "2246552",
          "3013077751",
          "3017119401",
          "3044545674",
          "3015612252",
          "3033043422",
          "3038187466",
          "3007487007",
          "3007111496",
          "3010684280",
          "3011063460",
          "3012627460",
          "3017636737",
          "3015895145",
          "3013665681",
          "3016555232",
          "3003117688",
          "3009719225",
          "3018126215",
          "3002808088",
          "3033507886",
          "3002807793",
          "3002681132",
          "3942",
          "3014656892",
          "3011459762",
          "3001556604",
          "3016079756",
          "3014635169",
          "3014579024",
          "3008615487",
          "3017619652",
          "3013942591",
          "3016832577",
          "3012811961",
          "3042940623",
          "3020331900",
          "1000499348",
          "2011171",
          "3002914049",
          "3015336263",
          "3014663814",
          "3001592626",
          "3004111573",
          "3002993297",
          "3001675293",
          "3007029079",
          "3012453745",
          "3010564249",
          "3002807095",
          "3009217531",
          "3002680121",
          "3018907196",
          "3015241782",
          "3002259632",
          "3015153469",
          "1000219637",
          "3013868968",
          "3010493171",
          "3013188547",
          "3003537036",
          "3009941480",
          "3008837339",
          "3005369776",
          "3010860245",
          "2936485",
          "3010157088",
          "3010193531",
          "3003898360",
          "3003076831",
          "3010432890",
          "3031594238",
          "3008309062",
          "3042953929",
          "3014309390",
          "3006149253",
          "3022626486",
          "3010885402",
          "1000512168"
        ],
        "device_name": "System, Surgical, Computer Controlled Instrument",
        "medical_specialty_description": "Gastroenterology, Urology",
        "regulation_number": "876.1500",
        "device_class": "2"
      }
    }
  ]
}