  "results": [
    {
      "cfres_id": "66385",
      "product_res_number": "Z-1159-2008",
      "event_date_initiated": "2007-11-13",
      "event_date_posted": "2008-06-11",
      "recall_status": "Terminated",
      "event_date_terminated": "2011-05-23",
      "res_event_number": "45875",
      "product_code": "LKJ",
      "k_numbers": [
        "K043341"
      ],
      "product_description": "BIOPLEX 2200 MULTI-ANALYTE DETECTION SYSTEM: a) 100 test - Catalog No. 665-1150; and b) the 5,000 tests - Catalog No. 665-1155 - manufactured by Bio-Rad Laboratories in Redmond, WA.  The product is used as an aid in the diagnosis of systemic autoimmune diseases.",
      "code_info": "Eleven (11) Lots, as follows: Lot Numbers: 931396 Exp. 9/30/06; 935424 Exp. 3/31/07; 941886 Exp. 3/31/07; 935682 Exp. 4/30/07; 937351 Exp. 6/30/07; 941343 Exp. 3/31/08; 941428 Exp. 4/30/08; 945246 Exp. 9/30/08; 945875 Exp. 12/31/08; 945248 Exp. 10/31/08 and 945875 Exp. 12/31/08   ****",
      "firm_fei_number": "3008272466",
      "recalling_firm": "Bio-Rad Laboratories",
      "address_1": "6565 185th Ave NE",
      "city": "Redmond",
      "state": "WA",
      "postal_code": "98052-5039",
      "additional_info_contact": "Scott J. Dennis\n425-498-1709",
      "reason_for_recall": "False negative results due to reagent packs exhibiting low signal.",
      "root_cause_description": "Nonconforming Material/Component",
      "action": "On 11/13/2007, the firm faxed Voluntary Field Correction Letters (which are dated 11/9/2007) to its consignees and also contacted them via telephone. The Voluntary Field Correction Letters: a) informed them of the potential for false negative results; b) recommended that they perform QC testing daily with each reagent pack; c) provided a new insert for the Instructions for Use; and d)  provided a Response Sheet for each consignee to complete and return to the firm.",
      "product_quantity": "8,804 kits",
      "distribution_pattern": "Worldwide Distribution -- USA, Canada, France, United Kingdom, Italy, Germany, South Africa, and Switzerland.",
      "openfda": {
        "k_number": [
          "K894411",
          "K034013",
          "K030775",
          "K021257",
          "K042416",
          "K024218",
          "K984470",
          "K954392",
          "K021103",
          "K932302",
          "K914550",
          "K954891",
          "K984473",
          "K882740",
          "K210902",
          "K874115",
          "K024226",
          "K954700",
          "K842484",
          "K883949",
          "K931255",
          "K885224",
          "K993294",
          "K041658",
          "K893897",
          "K932679",
          "K954723",
          "K831463",
          "K984475",
          "K081104",
          "K862313",
          "K842563",
          "K873249",
          "K984464",
          "K024232",
          "K961815",
          "K011244",
          "K984478",
          "K082759",
          "K932876",
          "K914454",
          "K113610",
          "K912291",
          "K913342",
          "K864668",
          "K024223",
          "K921132",
          "K920150",
          "K883883",
          "K893896"
        ],
        "device_name": "Antinuclear Antibody, Antigen, Control",
        "medical_specialty_description": "Immunology",
        "regulation_number": "866.5100",
        "device_class": "2",
        "registration_number": [
          "9610566",
          "2242436",
          "8043792",
          "2026994",
          "2915274",
          "3015376545",
          "1318354",
          "3004973408",
          "3003825930",
          "3039353646",
          "2918768",
          "3003935253",
          "1181055",
          "3007208259",
          "3032705",
          "9680745"
        ],
        "fei_number": [
          "3005774014",
          "3002807876",
          "2242436",
          "3002808269",
          "2026994",
          "2915274",
          "3015376545",
          "1318354",
          "3004973408",
          "3003825930",
          "3039353646",
          "2918768",
          "3003935253",
          "1181055",
          "3007208259",
          "3002701146"
        ]
      }
    }
  ]
}