  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-10-22",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 2
    }
  },
  "results": [
    {
      "cfres_id": "180058",
      "product_res_number": "Z-1618-2020",
      "event_date_initiated": "2019-12-06",
      "event_date_created": "2020-03-31",
      "recall_status": "Terminated",
      "event_date_terminated": "2022-07-01",
      "res_event_number": "85089",
      "product_code": "EQN",
      "product_description": "Karl Storz SE & Co. KG, C-MAC Video Laryngoscope MIL # 1, for the following REF numbers:\n\n1. 8403xx series, which includes: 8403AX, AXC, BX, BXC, DXC, EXC, GXC, HX, HXK, HXP, KXC, MXC  \n\n2. 8401xx series, which includes: 8401AX, AXC, BX, BXC, DXC, GXC, HX, HXP, KXC.\n\nProduct Usage: Video Laryngoscopes are used to visualize the airways and vocal cords during endotracheal intubation and for the inspection and examination of the upper respiratory tract. Video Laryngoscopes are designed for transient use in invasive procedures through a body orifice.",
      "code_info": "All Lots",
      "firm_fei_number": "3007475226",
      "recalling_firm": "Karl Storz Endoscopy",
      "address_1": "2151 E Grand Ave",
      "city": "El Segundo",
      "state": "CA",
      "postal_code": "90245-5017",
      "additional_info_contact": "Karl Storz Technical Support\n800-421-0837 Ext. 5350",
      "reason_for_recall": "The firm has become aware that there is a potential that the glass cover at the distal end of the camera/led lighting on the video laryngoscope could become loose during reprocessing or use. If this occurs during usage, it may result in a delay in procedure and/or require removal from body.",
      "root_cause_description": "Labeling Change Control",
      "action": "On 12/6/2019 a \"Urgent Medical device Correction\" letter was sent to affected customers via mail. In addition,  to providing information on the recall, the firm asked customers to take the following actions:\n\n1. Please forward this Safety Information to the appropriate departments in your organization.  \n\n2. Please train your employees on the new Instructions for Use, especially chapter 5.1.\n\n3. Please complete the attached acknowledgement form and return it to us.  \n \n4. If you have any questions about this communication, or needs additional copies of this Instruction for Use, please contact our Technical Support at 800-421-0837, Ext. 5350, Option 5.",
      "product_quantity": "27,165 scopes",
      "distribution_pattern": "Worldwide distribution - US Nationwide and country of Canada.",
      "openfda": {
        "k_number": [
          "K821710",
          "K781639",
          "K831255",
          "K782002",
          "K252624",
          "K821182",
          "K830888",
          "K821181",
          "K821706",
          "K821708",
          "K812734",
          "K834172",
          "K792222",
          "K822525",
          "K821707",
          "K821709",
          "K132039",
          "K770085",
          "K813297",
          "K811943",
          "K821269",
          "K150248"
        ],
        "device_name": "Laryngoscope, Nasopharyngoscope",
        "medical_specialty_description": "Ear, Nose, Throat",
        "regulation_number": "874.4760",
        "device_class": "2",
        "registration_number": [
          "9681246",
          "3003761012",
          "3006546082",
          "8010573",
          "3005527904",
          "9610617",
          "3010202439",
          "3010041511",
          "1926681",
          "3009118476",
          "3014342096",
          "3011137372",
          "3009010438",
          "3002807209",
          "3007532396"
        ],
        "fei_number": [
          "3003761012",
          "3002807522",
          "3006546082",
          "3005527904",
          "3005747797",
          "3003169291",
          "3010041511",
          "3007475226",
          "1926681",
          "3002808268",
          "3009118476",
          "3014342096",
          "3009010438",
          "3002807209",
          "3007532396"
        ]
      }
    }
  ]
}