{
  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-10-22",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 9
    }
  },
  "results": [
    {
      "cfres_id": "178194",
      "product_res_number": "Z-0678-2020",
      "event_date_initiated": "2019-12-03",
      "event_date_created": "2019-12-12",
      "recall_status": "Terminated",
      "event_date_terminated": "2020-09-18",
      "res_event_number": "84377",
      "product_code": "KFM",
      "k_numbers": [
        "K991864"
      ],
      "product_description": "Maquet Cardiopulmonary (MCP)/Getinge ROTAFLOW Drive, Model Number 701022161.  The device is a component of the ROTAFLOW System Console.",
      "code_info": "UDI: 04037691258997;  Serial Numbers 9348936 910114412 910114420 910114429 910114430 910114432 910114435 910114438 910117243 91064722 91067680",
      "firm_fei_number": "3008355164",
      "recalling_firm": "Maquet Cardiovascular Us Sales, Llc",
      "address_1": "45 Barbour Pond Dr",
      "city": "Wayne",
      "state": "NJ",
      "postal_code": "07470-2094",
      "additional_info_contact": "Maryanna Krivak\n973-709-7483",
      "reason_for_recall": "A loose ODU plug / Coaxial cable connection may result in fluctuating flow values on the Console.",
      "root_cause_description": "Nonconforming Material/Component",
      "action": "An Urgent Medical Device Recall notification letter dated 12/3/19 was sent to customers.\n\nIf your affected RFD unit is in clinical use, switch to RPM mode. Using hospital patient management protocols and physician judgement, perform the following steps:\n1. Check your inventory for an unaffected RFD unit . If an unaffected RFD unit is available, it should be at the clinicians discretion to transfer the patient from the affected unit to the unaffected unit.\n2. If an unaffected RFD unit is unavailable or if temporary interruption of extracorporeal blood flow is not\npossible check the following options:\na. Please check your inventory for an independent external flow measurement system to measure the actual flow. Only use a reliable external flow measurement that is gauged and zeroed. Use that measurement system in conjunction with the RPM mode. If necessary adjust the RPM according to the flow reading as obtained with the independent external flow measurement system. A continuous control of the patient vital signs monitoring is indicated. If the the Bubble Sensor intervention is already active, leave the setting in place.\nb. In case no external flow measurement system is available stay on RPM mode and continuously control vital signs monitoring. It is indicated to closely monitor the blood gases of the respective patient. The assessment of the vital sign monitoring and the blood gas analysis in conjunction with the indicated pump speed (RPM) is required. If the the Bubble Sensor intervention is already active, leave the setting in place.\n\n3. When treatment of patient is completed, remove your affected RFD unit from use and follow the Actions to be Taken for return and repair below.\nIf your affected RFD unit is not in clinical use, remove your affected RFD unit and follow the Actions to be Taken for return and repair below.\n\nActions to be taken\n1. Our records indicate that you have received a Rotaflow Drive Unit with a serial number that is affected by this",
      "product_quantity": "11 distributed in the US",
      "distribution_pattern": "The products were distributed to the following US states:  ME, NV, NY, OH, PA, TX, and VA.",
      "openfda": {
        "k_number": [
          "K991864",
          "K943861",
          "K983272",
          "K061072",
          "K921550",
          "K011835",
          "K110493",
          "K201068",
          "K232132",
          "K882758",
          "K033270",
          "K902404",
          "K183623",
          "K190650",
          "K020271",
          "K770937",
          "K103357",
          "K023132",
          "K083794",
          "K200091",
          "K020529",
          "K090051",
          "K012209",
          "K090515",
          "K201320",
          "K111657",
          "K991783",
          "K973011",
          "K012325",
          "K080774",
          "K913176",
          "K852698",
          "K192850",
          "K093801",
          "K233091",
          "K050109",
          "K202169",
          "K031300",
          "K083111",
          "K100631",
          "K972740",
          "K111658",
          "K191077",
          "K894255",
          "K082321",
          "K080470",
          "K902198",
          "K884659",
          "K250326",
          "K110845",
          "K962981",
          "K073631",
          "K133265",
          "K842007",
          "K170029",
          "K780953",
          "K933014",
          "K193663",
          "K032040",
          "K915547",
          "K851855",
          "K251762",
          "K992592",
          "K854975",
          "K903925",
          "K851613",
          "K013393",
          "K852807",
          "K952879",
          "K030154",
          "K051209",
          "K063723",
          "K112229",
          "K050890",
          "K882129",
          "K020998",
          "K912604",
          "K111972",
          "K915363",
          "K900601",
          "K111384",
          "K030462",
          "K132712",
          "K220842"
        ],
        "registration_number": [
          "3014990448",
          "3030125051",
          "3011554160",
          "1928237",
          "3003306248",
          "8010026",
          "2528981",
          "1319639",
          "2184009",
          "2916596",
          "1218444",
          "1828100",
          "3003661577",
          "1220648",
          "3012119238",
          "3002807090",
          "1422634",
          "3009380063",
          "3008792657",
          "3044156918",
          "9617601",
          "1124841",
          "3006073153",
          "1123137",
          "2011171",
          "3005941719",
          "3019807891",
          "9681834",
          "3016746283",
          "8010762",
          "2029275",
          "3010163695",
          "9680841",
          "3007427881",
          "3006849754",
          "3009507273"
        ],
        "fei_number": [
          "3014990448",
          "3030125051",
          "3002534070",
          "3005426550",
          "3011554160",
          "1928237",
          "3003306248",
          "2528981",
          "2916596",
          "1218444",
          "3012119238",
          "1220648",
          "1828100",
          "3003661577",
          "3002808327",
          "3009380063",
          "1000116158",
          "3008792657",
          "3044156918",
          "3002807111",
          "1000514656",
          "3006073153",
          "3000204839",
          "2011171",
          "3019807891",
          "1000123180",
          "1000138054",
          "3016746283",
          "1000306431",
          "2828",
          "3010163695",
          "3009649876",
          "3007427881",
          "3006849754",
          "3006003617",
          "3009507273"
        ],
        "device_name": "Pump, Blood, Cardiopulmonary Bypass, Non-Roller Type",
        "medical_specialty_description": "Cardiovascular",
        "regulation_number": "870.4360",
        "device_class": "2"
      }
    }
  ]
}