  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-11-26",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 12
    }
  },
  "results": [
    {
      "cfres_id": "181903",
      "product_res_number": "Z-2660-2020",
      "event_date_initiated": "2020-06-19",
      "event_date_posted": "2020-07-20",
      "recall_status": "Terminated",
      "event_date_terminated": "2022-07-29",
      "res_event_number": "85853",
      "product_code": "PTI",
      "k_numbers": [
        "K153440"
      ],
      "product_description": "PowerLoc MAX Power Injectable Infusion Set AllPoints Port Access System; Catalog Numbers AN132075 (UDI 00801741118968), AN142010 (UDI 00801741119231), AN142010G (UDI 00801741119323), AN142075 (UDI 00801741119224)",
      "code_info": "Catalog Numbers AN132075 (UDI 00801741118968), AN142010 (UDI 00801741119231), AN142010G (UDI 00801741119323), AN142075 (UDI 00801741119224).   Lot Numbers: REDT4257 REDV3617 REDY1815 REDY2789 REDZ0385 REEN2192 REEN2782 REDW2682 REDX1471 REDX3857 REDY0765 REDY1593 REDY2943 REDZ0676 REDZ1903 REDZ3077 REEN1222 REEN3292 REEP0666 REEP4137 REER0612 REDW1021 REDX1360 REDX4728 REDY1816 REDY2935 REDY3765 REDZ1825 REDZ3146 REEN1935 REEP0773 REEP3544 REEP4066 REER0579 REER1103 REDV2172 REDV3683 REDW0467 REDW0521 REDW1023 REDW1157 REDX1361 REDX1490 REDY0815 REDY1594 REDY2790 REDY3544 REDZ0110 REDZ0386 REDZ0677 REDZ1904 REDZ3078 REEN1072 REEN2186 REEN3075 REEN3310 REEP0663 REEP1401 REEP4138 REEQ0611 REEQ1246 REEQ2436 REEQ3589 REER0576 REER1046 REER2161 Additional lot added 10/16/20: REEU0314",
      "firm_fei_number": "2243072",
      "recalling_firm": "Becton Dickinson & Company",
      "address_1": "1 Becton Dr",
      "city": "Franklin Lakes",
      "state": "NJ",
      "postal_code": "07417-1815",
      "additional_info_contact": "Customer/Technical Support\n800-290-1689",
      "reason_for_recall": "Potential development of cracks or breaks in the tubing near the Luer or Y site of the device. Devices that have developed breaks or cracks can cause leakage resulting in exposure to chemicals such a chemotherapeutics or biohazard material (e.g., blood). A crack or break could result in potential blood loss, catheter occlusion, air embolism, under or interrupted infusion, or site contamination which could lead to infection.",
      "root_cause_description": "Process control",
      "action": "URGENT MEDICAL DEVICE RECALL notification letters dated 6/19/20 were sent to customers.\n\nPLEASE TAKE THE FOLLOWING ACTIONS:\n1. Immediately review your inventory for the specific catalog and lot numbers referenced in Attachment A. Discontinue use of those devices and destroy all product subject to this recall following your institutions process for destruction.\n\nMDS-20-1979 Page 2 of 28\nBD Medical\n1 Becton Drive\nFranklin Lakes, NJ 07417\nUSA\nbd.com\n2. Share this notification with all users of the product within your facility network to ensure they are also aware of this recall.\n3. Complete the attached Customer Response Form and return to the BD contact noted on the form whether or not you have any of the impacted material so that BD may acknowledge your receipt of this notification per FDA requirements and subsequently process your credit accordingly for the discarded material.\na. Customers who purchased product directly from BD will receive credit.\nb. Customers who did not purchase product directly from BD will need to contact their distributor to obtain credit.\n4. Report any adverse health consequences experienced with the use of this product to BD at product.complaints@bd.com. Events may also be reported to the FDA's MedWatch Adverse Event Reporting program via:\nWeb: MedWatch website at www.fda.gov/medwatch\nPhone: 1800FDA1088 (18003321088)\nMail: MedWatch, HF2, FDA, 5600 Fishers Lane, Rockville, MD 208529787\n\nCustomer/Technical Support\nPhone: 8002901689\nMonday  Friday between 8:00 am to 5:00 pm MDT\nSLCBASD.FieldAction@bd.com\n\nAn Urgent Medical Device Recall notification letter dated 8/25/20 was sent to customers informing them of two additional lots of affected product.\n\nAn URGENT MEDICAL DEVICE RECALL UPDATE dated 10/7/20 was sent to customers informing them of two additional lots of affected product.",
      "product_quantity": "5,296,132 total",
      "distribution_pattern": "Worldwide Distribution",
      "openfda": {
        "k_number": [
          "K251138",
          "K243332",
          "K200463",
          "K170897",
          "K171333",
          "K254095",
          "K162271",
          "K211121",
          "K230715",
          "K241353",
          "K213823",
          "K171735",
          "K170881",
          "K252355"
        ],
        "registration_number": [
          "3010055973",
          "1000163068",
          "3006082230",
          "3030733800",
          "3038356900",
          "9612086",
          "3015142721",
          "9617592",
          "3010421104",
          "2246552",
          "2518902",
          "3018507299",
          "3013557562",
          "3013764800",
          "1417592",
          "3044026004",
          "3048101437",
          "3003915875",
          "3030446844",
          "2245539",
          "1055927",
          "3010220595",
          "3017509841",
          "1221765",
          "3006260740",
          "3010515547",
          "2030624",
          "9615908",
          "3007829657",
          "9612452",
          "3015537318",
          "1018233",
          "3010149039",
          "2124215",
          "3005670221"
        ],
        "fei_number": [
          "3010055973",
          "1000163068",
          "3006082230",
          "3030733800",
          "3000206435",
          "3038356900",
          "1000113359",
          "3015142721",
          "3010421104",
          "2246552",
          "2518902",
          "3018507299",
          "3013557562",
          "3013764800",
          "1417592",
          "3044026004",
          "3048101437",
          "3003915875",
          "3030446844",
          "3002468371",
          "2245539",
          "3010220595",
          "3017509841",
          "1221765",
          "3006260740",
          "3010515547",
          "3007829657",
          "3015537318",
          "1018233",
          "3002806713",
          "3010149039",
          "3003282181",
          "2124215",
          "3005670221",
          "3002806575"
        ],
        "device_name": "Non-Coring (Huber) Needle",
        "medical_specialty_description": "General Hospital",
        "regulation_number": "880.5570",
        "device_class": "2"
      }
    }
  ]
}