      "cfres_id": "166759",
      "product_res_number": "Z-3247-2018",
      "event_date_initiated": "2018-07-18",
      "event_date_created": "2018-09-25",
      "recall_status": "Terminated",
      "event_date_terminated": "2020-01-22",
      "res_event_number": "80865",
      "product_code": "PPN",
      "k_numbers": [
        "K180454"
      ],
      "product_description": "The Shockwave S4 IVL Catheters are intended for lithotripsy-enhanced balloon dilatation of lesions, including calcified lesions, in the peripheral vasculature, including the iliac, femoral, ilio-femoral, popliteal, infra-popliteal, and renal arteries.  Shockwave S4, Peripheral Intravascular Lithotripsy Catheter, CE 0086, STERILE R,\nManufacturer: Shockwave Medical, Inc. 48501 Warm Springs Blvd. Ste. 108, Fremont, CA 94539",
      "code_info": "Catalog No.\tPart No.                   Size\t                Lot #\t      UDI (DI Portion Only)     S4IVL2540\tFG61163-2540\t2.50x40mm\tP180222I       M732S4IVL25400                                                                                 P180327A                                                                                 P180410A                                                                                 P180503A\t S4IVL3040\tFG61163-3040\t3.00x40mm\tP180223A      M732S4IVL30400                                                                                 P180327B                                                                                 P180410B                                                                                 P180503B\t S4IVL3540\tFG61163-3540\t3.50x40mm\tP180223B      M732S4IVL35400                                                                                 P180327C                                                                                 P180410C                                                                                 P180503C\t S4IVL4040\tFG61163-4040\t4.00x40mm\tP180223C     M732S4IVL40400                                                                                 P180327D                                                                                 P180410D                                                                                 P180503D",
      "firm_fei_number": "3015053858",
      "recalling_firm": "Shockwave Medical, Inc.",
      "address_1": "48501 Warm Springs Blvd Ste 108 48501 Warm Springs Blvd",
      "address_2": "Ste 108",
      "city": "Fremont",
      "state": "CA",
      "postal_code": "94539-7750",
      "additional_info_contact": "Nora Hadding\n510-279-4262",
      "reason_for_recall": "Catheter unable to maintain inflation pressure during treatment (4ATM) and/or during IVL post dilatation (at 6ATM).",
      "root_cause_description": "Process control",
      "action": "On 7/19/2018, the firm sent an Urgent Medical Device Recall Notice to  distribution chain/consignees via e-mail informing them that, in some cases, the S4 Peripheral IVL Catheter is not performing as intended. We have seen instances of leaks in the balloon which prevent the balloon from staying inflated at 4 atm for the full course of lithotripsy application. There have been no reports of adverse clinical events related to this issue. This issue does not impact patients who were previously treated with the S4 device.\n\nCustomers were instructed to discontinue use of all S4 IVL products listed in the recall and place it into quarantine until a Shockwave representative was able to arrange for the S4 IVL product to be returned to Shockwave Medical.\n\nThe Shockwave representative retrieving the product from the customer is to complete the Acknowledgement and Receipt Form.\n\nRecall Contact\nNora Hadding\nVice President, Quality and Regulatory Affairs\nEmail: nhadding@shockwavemedical.com\nPhone: 510-279-4262\nMonday through Friday, 8:00 AM to 4:30 PM Pacific time.",
      "product_quantity": "612",
      "distribution_pattern": "Domestic: CO, TN and TX\nForeign: Austria, Germany and New Zealand",
      "openfda": {
        "k_number": [
          "K221041",
          "K250225",
          "K260246",
          "K262201",
          "K240954",
          "K221852",
          "K180454",
          "K242213",
          "K240225",
          "K161384",
          "K203365",
          "K191840",
          "K180958",
          "K163306"
        ],
        "registration_number": [
          "3012102437",
          "3007738736",
          "2030624",
          "3014222368",
          "2030598",
          "3015053858",
          "3027545377",
          "3041000776",
          "1000121056",
          "3010273872",
          "2124215",
          "3004363082",
          "3010086866",
          "3009018440"
        ],
        "fei_number": [
          "3012102437",
          "3007738736",
          "3004363082",
          "3014222368",
          "3015053858",
          "3027545377",
          "3041000776",
          "1000518731",
          "1000121056",
          "3010273872",
          "2124215",
          "3000206435",
          "3010086866",
          "3009018440"
        ],
        "device_name": "Percutaneous Catheter, Ultrasound",
        "medical_specialty_description": "Cardiovascular",
        "regulation_number": "870.1250",
        "device_class": "2"
      }
    }
  ]
}