  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-11-26",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 18
    }
  },
  "results": [
    {
      "cfres_id": "221916",
      "product_res_number": "Z-0068-2027",
      "event_date_initiated": "2024-09-17",
      "event_date_posted": "2026-10-01",
      "recall_status": "Open, Classified",
      "res_event_number": "99585",
      "product_code": "PFF",
      "product_description": "NovaSeq 6000Dx including DRAGEN Server,  Catalog Number: 20068232; \nIllumina DRAGEN Server for NextSeq 550Dx, Catalog Number: 20086130",
      "code_info": "Catalog/UDI-DI/Serial Numbers:\n20068232/00816270020637/ADX00020, ADX00114, ADX00121, ADX00124, ADX00147, ADX00151, ADX00139, ADX00105, ADX00103, ADX00108, ADX00104, ADX00106, ADX00101, ADX00115, ADX00111, ADX00112, ADX00117, ADX00119, ADX00116, ADX00118, ADX00125, ADX00126, ADX00131, ADX00120, ADX00128, ADX00138, ADX00142, ADX00143, ADX00144, ADX00150, ADX00146, ADX00141, ADX00133, ADX00134, ADX00122, ADX00127, ADX00130, ADX00135, ADX00140, ADX00136, ADX00137, ADX00148, ADX00149, ADX00152, ADX00153.\n\n20086130/ACN7003517, ACN7003523, ACM5003172, ACMC007033, ACN7003530, ACM6002504, ACM5003179, ACM4005610, ACN7003516, ACN1003268, ACN1003269, ACN1003262, ACM6002503, ACN7003532, ACN1003255, ACN7003531, ACN7003518, ACN1003258, ACN1003248, ACM9002241, ACM5002946, ACM9002243, ACM6002498, ACM6002015, ACN1003254, ACN1003271, ACN1003257, ACM6002494, ACMC007031, ACMC007048, ACN1003259, ACN1003256, ACN8002480, ACO2000280, ACO7001263",
      "firm_fei_number": "3003218906",
      "recalling_firm": "Illumina, Inc.",
      "address_1": "5200 Illumina Way",
      "city": "San Diego",
      "state": "CA",
      "postal_code": "92122-4616",
      "additional_info_contact": "Christine Douglass\n971-295-9188",
      "reason_for_recall": "Retrospectively reported correction for an instrument intended for targeted sequencing of DNA libraries from human genomic DNA used with in vitro diagnostic assays has a server with a security vulnerability.",
      "root_cause_description": "Software design",
      "action": "On 9/17/2024, and 1/16/2025 field safety notices were emailed to customers who were asked to take actions on webpage: https://support.illumina.com/support-content/bmc.html \n\nCustomers were also asked to complete and return the Verification Form via email to\ntechsupport@illumina.com  This email can also be used to ask questions or to report potentially compromised servers.",
      "product_quantity": "80",
      "distribution_pattern": "Worldwide - US Nationwide distribution in the states of TX, KS, NC, CA, UT, KA, MA, NJ, MD and the countries of Spain, South Korea, Japan, Australia, Italy, United Arab Emirates, Sweden, United Kingdom, Czech Republic, Singapore, Austria, Poland, France, Germany, Finland, Switzerland, Slovakia.",
      "openfda": {
        "k_number": [
          "DEN130011",
          "K170299"
        ],
        "registration_number": [
          "3015529000",
          "",
          "3009875001",
          "3006296346",
          "3007287152",
          "3003673482",
          "3007102730",
          "3011104381",
          "3003335080",
          "3003218906",
          "3014150341",
          "3009207631"
        ],
        "fei_number": [
          "3015529000",
          "",
          "3009875001",
          "3007287152",
          "3003673482",
          "3007102730",
          "3011104381",
          "3003335080",
          "3003218906",
          "3014150341",
          "3005095756",
          "3009207631"
        ],
        "device_name": "High Throughput Dna Sequence Analyzer",
        "medical_specialty_description": "Immunology",
        "regulation_number": "862.2265",
        "device_class": "2"
      }
    }
  ]
}