  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-11-26",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 2
    }
  },
  "results": [
    {
      "cfres_id": "127364",
      "product_res_number": "Z-1837-2014",
      "event_date_initiated": "2014-05-07",
      "event_date_posted": "2014-06-19",
      "recall_status": "Terminated",
      "event_date_terminated": "2015-10-30",
      "res_event_number": "68310",
      "product_code": "PBI",
      "k_numbers": [
        "K121874"
      ],
      "product_description": "G7 Acetabular System Positioning Guide Rod, orthopedic surgical instrument for hip prosthesis PN 110003458.",
      "code_info": "PN:110003458. Lots 424960, ZB130702, ZB130703, ZB130704, ZB130705, ZB130701, ZB131201, 360877, 377304 and ZB140201.",
      "firm_fei_number": "1825034",
      "recalling_firm": "Biomet, Inc.",
      "address_1": "56 E Bell Dr",
      "city": "Warsaw",
      "state": "IN",
      "postal_code": "46582-6989",
      "additional_info_contact": "574-267-6639 Ext. 1676",
      "reason_for_recall": "Guide rod may fracture during impaction of the acetabular shell and be retained in the inserter or the patient and could result in a delay in surgery.",
      "root_cause_description": "Use error",
      "action": "The firm issued the following notice on May 7, 2014: URGENT MEDICAL DEVICE RECALL NOTICE:\r\nThis notification is to inform you of an Urgent Medical Device Recall initiated by Biomet Orthopedics (\"Biomet\") which involves Part Numbers: 110003458 G7 Positioning Guide Rod and 110003500 G7 Positioning Guide Post.  These instruments have been consigned and/or invoiced to your account. Biomet has initiated this action following an investigation which identified that positioning guide rod may fracture during impaction of the acetabula shell. If the positioning guide rod fractures, then the positioning guide post may become stuck to the insertion handle. There is no adverse health outcome expected for the patient.\r\nThis action requires the immediate location and discontinued use of the product and its return to Biomet.\r\nThe following actions are REQUIRED:\r\nImmediately locate and remove the identified device(s) listed below from circulation.\r\nCarefully follow the instructions on the enclosed \"FAX Back Response Form.\r\nFax a copy of the Response Form to 574-372-1683 prior to return of product.\r\nUse priority carrier for your shipment.\r\nIf you have further distributed this product, you MUST notify hospital personnel of this action via the enclosed \"Dear Risk/Recall Manager\" notice. This letter MUST be given to hospital personnel responsible for receiving recall notices. However, you are charged with the location and return of these products.",
      "product_quantity": "1047 total",
      "distribution_pattern": "Worldwide Distribution-USA (nationwide) and the countries of Canada, Netherlands, New Zealand, and Japan.",
      "openfda": {
        "k_number": [
          "K121874",
          "K212512"
        ],
        "registration_number": [
          "2648920",
          "3013055499",
          "3020282716",
          "8043792",
          "3012319330",
          "3010386387",
          "3015542154",
          "3012725451",
          "3002807315",
          "3014302784",
          "3010173425",
          "1529009",
          "1828464",
          "1834379",
          "3004748528",
          "3004153896",
          "3002807310",
          "9617840",
          "3011683674",
          "3005360851",
          "3015207155",
          "3005061536",
          "1526534",
          "3013176080",
          "1423662",
          "1822565",
          "3007923096",
          "1424263",
          "1825034",
          "3006801265",
          "1450662",
          "3035366890"
        ],
        "fei_number": [
          "3013055499",
          "1000132037",
          "3020282716",
          "1000220733",
          "3012319330",
          "3010386387",
          "1000306303",
          "3015542154",
          "3012725451",
          "3002807315",
          "3003714383",
          "3014302784",
          "3000215273",
          "3003015552",
          "1828464",
          "3004748528",
          "3004153896",
          "3002807310",
          "3011683674",
          "3002808269",
          "3005360851",
          "3015207155",
          "3005061536",
          "1526534",
          "3013176080",
          "3007923096",
          "1825034",
          "3002807036",
          "3006801265",
          "1450662",
          "3035366890",
          "1000149660"
        ],
        "device_name": "Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer, + Additive",
        "medical_specialty_description": "Orthopedic",
        "regulation_number": "888.3310",
        "device_class": "2"
      }
    }
  ]
}