  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-11-26",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 4
    }
  },
  "results": [
    {
      "cfres_id": "185333",
      "product_res_number": "Z-0959-2021",
      "event_date_initiated": "2020-12-14",
      "event_date_created": "2021-02-05",
      "recall_status": "Terminated",
      "event_date_terminated": "2022-09-28",
      "res_event_number": "87099",
      "product_code": "OFC",
      "product_description": "PRYTIME MEDICAL REBOA Catheter Introducer Kit, REF: KT1835C,  \nContents: Needle, 18 GA x 7 CM ECHOGENIC, STERILE, 1 EA, SYRINGE, 30CC, STERILE 1 EA, INTRODUCER SHEATH KIT, 7 FR W/.035 SHORT GUIDEWIRE, STERILE 1 EA., PREFILLED, STERILE FIELD SALINE SYRINGE, 10 ML, 4 EA, CLAMP, 5 FR, STERILE, 1 EA, SCALPEL, #11SS, STERILE, 1 EA, SUTURE, NYLON, 18\", 2-0, REVERSE CUTTING, STERILE 1 EA, THREE QUARTER DRAPE, STERILE 1 EA, INSERT, SALINE 1 EA, INSERT, CLAMP 1 EA\nUDI: (01) 0 0863092 00010 1",
      "code_info": "Lot # MFG 3590",
      "firm_fei_number": "3026788751",
      "recalling_firm": "Prytime Medical Devices, Inc.",
      "address_1": "229 N Main St",
      "city": "Boerne",
      "state": "TX",
      "postal_code": "78006-2035",
      "additional_info_contact": "Brian Young\n210-340-0116",
      "reason_for_recall": "There is a potential that a catheter convenience set contains a 21G access needle instead of the correct 18G needle. If the 21G needle is used to gain vascular access then the guidewire included in the kit will not pass through the access needle to facilitate insertion of an introducer sheath and could therefore cause procedure delay or injury.",
      "root_cause_description": "Mixed-up of materials/components",
      "action": "On 12/14/2020, Prytime Medical sent an \"Urgent Medical Device Recall Notification\" to affected consignees via FedEx. In addition to informing consignees about the recall, the firm asked consignees to take the following actions:\n\n1) Please immediately review your inventory for the recalled lot specified in this notification.\nQuarantine and do NOT use this lot.\n\n2) If you have an urgent need for this kit, and dont have an alternative lot available then please\nensure that you have a backup 18 gauge access needle readily available at the point of use.\nDo not use the 21G access needle in the kit.\n\n3) Immediately complete and return the attached Customer Response Form to the contact on\nthe form.\na. Please specify the number of affected kits in your possession.\nb. Prytime will promptly contact you to arrange return and replacement shortly after\nreceiving the completed form.\n\n4) Share this recall notification with any users of the product within your facilities, or anyone else\nyou may have sent the product to, in order to ensure they are also aware of this recall.\n\n5) Report any adverse health consequences experienced with the use of this product to Prytime\nusing the attached form, or by email at recall@prytimemedical.com, or by phone at (210)\n340-0116.\n\n\nIf you have any questions or discover any additional REBOA Convenience Set KT1835C Lot\nMFG3590 at your facility please contact the Recall Coordinator by phone at (210) 340-0116, or by\nemail at recall@prytimemedical.com.",
      "distribution_pattern": "US Nationwide distribution including in the states of NJ, NY, CA, TX, MI, MO, CO, MI, VA, DE, TN, MO, MT, AZ, FL, WI, SC, WA, TX, CT, IN, PA, ME, WI, MA, GA, OH, AR, UT, NY\n\nOUS: None",
      "openfda": {
        "registration_number": [
          "3008258694",
          "9616088",
          "1220477",
          "3004111573",
          "3007329020",
          "3003898360",
          "2134812",
          "3009888344",
          "3004911384",
          "3011137372",
          "3015859709",
          "1061124",
          "3005704822",
          "3007284006",
          "3016112537",
          "1223004",
          "2245270",
          "9681202",
          "3009756153",
          "3012279212",
          "2030624",
          "9680794",
          "1724474",
          "3013666218",
          "3026788751",
          "1423537",
          "1643817"
        ],
        "fei_number": [
          "3003737899",
          "3008258694",
          "1220477",
          "3004111573",
          "3007329020",
          "3000206435",
          "3003898360",
          "3002902735",
          "3001236905",
          "3009888344",
          "3004911384",
          "3008737795",
          "1000512168",
          "3015859709",
          "3005704822",
          "3003094851",
          "3007284006",
          "3016112537",
          "1000120555",
          "2245270",
          "3009756153",
          "3012279212",
          "3005747797",
          "3002827704",
          "3013666218",
          "3026788751",
          "1643817"
        ],
        "device_name": "Catheter Introducer Kit",
        "medical_specialty_description": "Cardiovascular",
        "regulation_number": "870.1340",
        "device_class": "2",
        "k_number": [
          "K093257"
        ]
      }
    }
  ]
}