  "results": [
    {
      "cfres_id": "106767",
      "product_res_number": "Z-0934-2012",
      "event_date_initiated": "2011-12-22",
      "event_date_posted": "2012-02-01",
      "recall_status": "Terminated",
      "event_date_terminated": "2014-01-09",
      "res_event_number": "60911",
      "product_code": "NQQ",
      "k_numbers": [
        "K042894"
      ],
      "product_description": "Imalux Niris OCT Imaging System Probe, Model Number 1300, Serial Number F464019, IMALUX Corporation, Cleveland, OH\n\nThe Niris Imaging System probe is used with the Niris Imaging System. The Niris Imaging System employs Optical Coherence Tomography (OCT), which can be used to construct high spatial resolution. The probe, is attached to the Imaging Console, and is used to direct light to and from the patient tissue. A small electromechanical scanning mechanism in the probe moves the optical beam laterally across the tissue surface while simultaneously acquiring in-depth backscattering profile at each lateral position. The probe is not labeled or sold as sterile.",
      "code_info": "Model Number 1300, Serial Number F464019",
      "firm_fei_number": "3003883695",
      "recalling_firm": "Imalux Corporation",
      "address_1": "1771 E 30th St",
      "city": "Cleveland",
      "state": "OH",
      "postal_code": "44114-4407",
      "additional_info_contact": "216-502-0755 Ext. 301",
      "reason_for_recall": "During an FDA inspection, the firm was notified that the wrong tubing was used during the manufacture of the probe for the unit.",
      "root_cause_description": "Process control",
      "action": "Imalux Corp contacted their one customer via telephone on December 14, 2011. They informed the customer of the problem and requested the probe returned.  \n\nThe probe involved was returned and received by Imalux on December 22, 2011, and  will be stored offsite in quarantine.\n\nAny further questions please call  (216) 502-0755 ext. 301.",
      "product_quantity": "One Unit",
      "distribution_pattern": "Nationwide Distribution only to Texas.",
      "openfda": {
        "k_number": [
          "K151286",
          "K162466",
          "K232386",
          "K230691",
          "K242239",
          "K210458",
          "K150878",
          "K252851",
          "K253101",
          "K182616",
          "K102599",
          "K190404",
          "K242098",
          "K132800",
          "K120800",
          "K243016",
          "K242924",
          "K160878",
          "K192922",
          "K152120",
          "K160240",
          "K150237",
          "K191117",
          "K111201",
          "K183320",
          "K042894",
          "K121195",
          "K123369",
          "K171560",
          "K033783",
          "K251198",
          "K153283",
          "K251730",
          "K182261",
          "K250684",
          "K221257",
          "K112770",
          "K203578",
          "K153479",
          "K201552",
          "K143678",
          "K240610",
          "K093520",
          "K093857",
          "K253459",
          "K133209"
        ],
        "registration_number": [
          "3004837686",
          "2024311",
          "3043527620",
          "3012198618",
          "3042970803",
          "3013440400",
          "3012179728",
          "1220477",
          "1221051",
          "2024168",
          "3009882464",
          "2246552",
          "3007603861",
          "3004091615",
          "2245304",
          "3011578544",
          "3017654247",
          "3015542130",
          "2030624",
          "3013276158",
          "3021630097",
          "3042929028",
          "3005228872",
          "3009600098",
          "3027259266",
          "9680579",
          "3013351723"
        ],
        "fei_number": [
          "1000203464",
          "3004837686",
          "2024311",
          "3000206435",
          "3043527620",
          "3012198618",
          "3042970803",
          "3012179728",
          "1220477",
          "1221051",
          "2024168",
          "3009882464",
          "2246552",
          "3007603861",
          "3004091615",
          "2245304",
          "3011578544",
          "3017654247",
          "3015542130",
          "3013276158",
          "3021630097",
          "3042929028",
          "3005228872",
          "3009600098",
          "3027259266",
          "3013440400",
          "3013351723"
        ],
        "device_name": "System, Imaging, Optical Coherence Tomography (Oct)",
        "medical_specialty_description": "Radiology",
        "regulation_number": "892.1560",
        "device_class": "2"
      }
    }
  ]
}