  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-11-26",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 4
    }
  },
  "results": [
    {
      "cfres_id": "74751",
      "product_res_number": "Z-0594-2009",
      "event_date_initiated": "2008-09-26",
      "event_date_posted": "2009-01-02",
      "recall_status": "Terminated",
      "event_date_terminated": "2010-04-27",
      "res_event_number": "50111",
      "product_code": "LYT",
      "k_numbers": [
        "K023959",
        "K040363"
      ],
      "product_description": "Ossur 3'\" Titanium Skull Pin, 1 pack,  Model Number: 516V2S",
      "code_info": "Lot Number: 08060410",
      "firm_fei_number": "3003764610",
      "recalling_firm": "Ossur",
      "address_1": "Grjothals 5 5 grjothals",
      "city": "Reykjavik",
      "country": "Ireland",
      "reason_for_recall": "Ossur has initiated this voluntary recall as a precautionary measure because the firm is unable to guarantee the sterility of the affected products.",
      "root_cause_description": "Packaging process control",
      "action": "Ossur initiated contact with the customers to locate the pins on Sept. 26, 2008\nwith the Product Manager for this device contacting each consignee by phone.\nThe customers were informed the recall was initiated because the firm was unable to guarantee the sterility of the affected products.  Customers were asked to check their inventory for the affected parts. \n\nIf products were located, they were informed that an Ossur customer service representative will be emailing you with return information any they are to return these pins to the firm as soon as possible.  They were also told Ossur does not currently have replacement product available, but they will contact them immediately when they are available.\n\nIf the products were not located, they were asked to determine where these pins are currently located, if they have been applied to a patient?  If so, are they able to track down that patient and bring them in for an evaluation?",
      "product_quantity": "27 pouches (1 pin/per pouch) = 27 pins",
      "distribution_pattern": "Nationwide Distribution --- including states of FL, KS, MI, MO, NY, & WA.",
      "openfda": {
        "k_number": [
          "K040363",
          "K902676",
          "K914812",
          "K831072",
          "K912762",
          "K983685",
          "K902053",
          "K980594",
          "K883576"
        ],
        "registration_number": [
          "3013014058",
          "3010173425",
          "9616680",
          "9610726",
          "2249697",
          "2183463",
          "3008556682"
        ],
        "fei_number": [
          "3013014058",
          "3003070421",
          "3002807172",
          "3002459190",
          "2183463",
          "3008556682",
          "3002807036"
        ],
        "device_name": "Fixation Accessory",
        "medical_specialty_description": "Orthopedic",
        "regulation_number": "888.3030",
        "device_class": "2"
      }
    }
  ]
}