  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-11-26",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 7
    }
  },
  "results": [
    {
      "cfres_id": "150822",
      "product_res_number": "Z-0716-2017",
      "event_date_initiated": "2016-10-31",
      "event_date_created": "2016-12-07",
      "recall_status": "Terminated",
      "event_date_terminated": "2017-11-03",
      "res_event_number": "75570",
      "product_code": "LWR",
      "pma_numbers": [
        "P150011"
      ],
      "product_description": "Perceval Sutureless Aortic Heart Valve size S, Item # ICV1208, REF PVS21; Perceval Sutureless Aortic Heart Valve size M, Item # ICV1209, REF PVS23; Perceval Sutureless Aortic Heart Valve size L, Item # ICV1210, REF PVS25; Perceval Sutureless Aortic Heart Valve size XL, Item # ICV1211, REF PVS27.\n\nThe Perceval bioprosthesis is indicated for the replacement of diseased, damaged, or malfunctioning native or prosthetic aortic valves.",
      "code_info": "All Lots",
      "firm_fei_number": "1718850",
      "recalling_firm": "Sorin Group USA, Inc.",
      "address_1": "14401 W 65th Way",
      "city": "Arvada",
      "state": "CO",
      "postal_code": "80004-3503",
      "additional_info_contact": "Joan Ceasar\n303-467-6306",
      "reason_for_recall": "Sorin Group USA, Inc. announces a voluntary field action for the Perceval Sutureless Heart Valve due to updated steps associated with the implantation procedure.",
      "root_cause_description": "Use error",
      "action": "The firm, LivaNova, sent a \"Customer Letter\" dated 10/31/2016 to its Consignees with clarifications about the implant of the Perceval Sutureless Aortic Valve. The letter described the product, problem and actions to be taken. The consignees were instructed to reinforce the steps that may influence procedural success and mitigate potential complications and complete and return the Customer Response Form via fax to: LivaNova Canada Corp, Canada at +1 303 895 2335 or email to: HV.FEEDBACK@LIVANOVA.COM.\n\nIf you have additional questions or request of clarifications, please contact your LivaNova representative or Customer Service.\n\nFor questions regarding this customer letter, please contact your LivaNova sales representative or email: hv.feedback@livanova.com.",
      "product_quantity": "845 units",
      "distribution_pattern": "Worldwide Distribution-US (Nationwide) including states of: MD, ME, MA, NH, NY, NJ, AL, MS, VA, FL, CA, HI, TN, GA, WI, TX, MI, OH, KS, MN, NC, IL, IN, WA MO, PA, NM, and UT and countries of: Austria, Australia, Belgium, Bulgaria, Brazil, Canada, Chile, Colombia, Croatia, Czech Republic, Egypt, Finland, France, Germany, Greece, Hong Kong, Hungary, Jordan, India, Italy, Iran, Islamic Republic of, Ireland, Israel, Korea, Republic of, Kuwait,  Luxembourg, Malaysia, Malta, Mexico, Netherland, New Zealand, Norway, Panama, Poland, Portugal, Saudi Arabia, Serbia, Singapore, Slovakia, Slovenia, South African, Spain, Switzerland, Romania, Russian Federation,Taiwan, Province of China, Thailand, Turkey, United Arab Emirates, United Kingdom, and Uruguay.",
      "openfda": {
        "pma_number": [
          "P040021",
          "P100029",
          "P150036",
          "P130011",
          "P970031",
          "P060025",
          "P790007",
          "P060038",
          "P990064",
          "P970030",
          "P150011",
          "P150048",
          "P170006"
        ],
        "registration_number": [
          "",
          "2015691",
          "3005687633",
          "2025587",
          "2011171",
          "3010432890",
          "3001883144",
          "3007063218",
          "3002806603",
          "3012179728",
          "9612515",
          "2135147",
          "3015287573",
          "3010421104",
          "3044156918",
          "3007113487",
          "9617601",
          "2030624",
          "1721676",
          "2183744",
          "3004478276",
          "3008500478",
          "3014918977"
        ],
        "fei_number": [
          "",
          "2015691",
          "3005687633",
          "2025587",
          "3000206435",
          "2011171",
          "3010432890",
          "3002534070",
          "3001883144",
          "3007063218",
          "3002806603",
          "3012179728",
          "3015287573",
          "3010421104",
          "3002808437",
          "1713910",
          "3044156918",
          "3007113487",
          "1721676",
          "3005334138",
          "2183744",
          "3004478276",
          "3014918977"
        ],
        "device_name": "Heart-Valve, Non-Allograft Tissue",
        "medical_specialty_description": "Unknown",
        "regulation_number": "",
        "device_class": "3"
      }
    }
  ]
}