  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-11-26",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "185460",
      "product_res_number": "Z-1107-2021",
      "event_date_initiated": "2020-12-14",
      "event_date_posted": "2021-02-11",
      "recall_status": "Terminated",
      "event_date_terminated": "2022-08-04",
      "res_event_number": "87161",
      "product_code": "LSW",
      "k_numbers": [
        "K072393"
      ],
      "product_description": "EliA dsDNA Well - Product Usage: intended for the In-Vitro quantitative measurement of IgG antibodies directed to dsDNA in human serum and plasma as an aid in the clinical diagnosis of systemic lupus erythematosus (SLE). Material Number: 14-5500-01",
      "code_info": "Carrier Lot Number:\tBFA3Y; Kit Lot Number: 0142; (UDI): 07333066019406",
      "firm_fei_number": "3002807876",
      "recalling_firm": "Phadia US Inc",
      "address_1": "4169 Commercial Ave",
      "city": "Portage",
      "state": "MI",
      "postal_code": "49002-9701",
      "additional_info_contact": "Phadia recall public contact\n269-833-1819",
      "reason_for_recall": "Decreased values for EliA ANA Positive Control when using the EliA dsDNA Well lot BFA37/0142 may potentially cause false positive results (increase in patient test results).",
      "root_cause_description": "Under Investigation by firm",
      "action": "Phadia US Inc. (Initial Importer/Distributor) issued notification to consignees via phone and FedEx overnight delivery Dec. 17-18 . Letter states reason for recall, health risk and action to take: \n\nCustomers are asked to perform the following steps:\n1.Scrap EliA dsDNA Well lot BFA3Y/0142 and order a replacement free of charge\n2. Assess test results from EliA dsDNA Well lot BFA3Y/0142 and determine if retesting of samples is warranted in accordance with internal operating procedures.\n3. Complete the Acknowledgement Form in the Medical Device Field Safety Notice and return the response to the contact person described.\n\nAny questions concerning this issue, contact Phadia US Technical Support at 1-800-346-4364, option #2.",
      "product_quantity": "365 kits US",
      "distribution_pattern": "US Nationwide distribution.",
      "openfda": {
        "k_number": [
          "K081251",
          "K872085",
          "K041628",
          "K921658",
          "K072393",
          "K172348",
          "K152013",
          "K060380"
        ],
        "device_name": "Anti-Dna Antibody, Antigen And Control",
        "medical_specialty_description": "Immunology",
        "regulation_number": "866.5100",
        "device_class": "2",
        "registration_number": [
          "3012348571",
          "3003935253",
          "1222302",
          "9610566",
          "3039353646",
          "2026994",
          "3003825930",
          "3004973408",
          "8043792"
        ],
        "fei_number": [
          "3002807876",
          "3012348571",
          "3003935253",
          "3039353646",
          "2026994",
          "1000121039",
          "3002808269",
          "3003825930",
          "3004973408"
        ]
      }
    }
  ]
}