  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-11-26",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 5
    }
  },
  "results": [
    {
      "cfres_id": "106251",
      "product_res_number": "Z-0629-2012",
      "event_date_initiated": "2011-04-15",
      "event_date_posted": "2012-01-11",
      "recall_status": "Terminated",
      "event_date_terminated": "2013-01-15",
      "res_event_number": "60702",
      "product_code": "LDR",
      "k_numbers": [
        "K905498"
      ],
      "product_description": "STAT 2  I.V. Controller, Catalog/REF No. S2, ASSEMBLED IN MEXICO, CONMED CORPORATION, 525 FRENCH ROAD, UTICA, NY 13502 --- This is a disposable device with a sterile, nonpyrogenic fluid path. \n\nFor controlling the infusion of Intravenous fluids into the human body.",
      "code_info": "Beginning Lot Code 1007195, Ending Lot Code 1010085",
      "firm_fei_number": "3001451571",
      "recalling_firm": "ConMed Corporation",
      "address_1": "525 French Road",
      "city": "Utica",
      "state": "NY",
      "postal_code": "13502",
      "additional_info_contact": "M. Patricia Cotter\n315-624-3533",
      "reason_for_recall": "ConMed received complaints of some units exhibiting inaccurate or inconsistent flow rates.  It was determined that certain units were assembled with an incorrect component which could result in the devices exhibiting a different flow rate and might reduce the ability of the user to regulate the device at low flow rates.",
      "root_cause_description": "Mixed-up of materials/components",
      "action": "ConMed Corporation sent Urgent Medical Device Recall Letters and Response Forms dated April 14, 2011, via UPS Priority Mail pouches to all domestic consignees.  The letter identified the product, the problem, and the action to be taken by the consignee.   The international consignees were sent Urgent Medical Device Recall Letters and Response Forms dated April 22, 2011,  via FedEx International Priority.  Users were instructed to immediately stop use of the device and return it to ConMed Corporation. --- RECALL EXPANSION:  Consignees were also instructed to contact all of those organization within their facility and any other facilities that they may have supplied or given these affected products to.  ConMed Corp. sent out Amended Urgent Medical Device Recall Letters and Response Forms dated May 10, 2011, to the  4 consignees via UPS PriorIty Mail for the expansion of the recall for Catalog No. S2-12N, Lot 1006234.\n\nFor any questions call 315-624-3237 or email ivcontroller@conmed.com.",
      "distribution_pattern": "Worldwide Distribution - USA (nationwide) and the countries of  Canada, Panama and India",
      "openfda": {
        "k_number": [
          "K971826",
          "K834528",
          "K971865",
          "K863204",
          "K830780",
          "K870132",
          "K963136",
          "K822891",
          "K812233",
          "K934543",
          "K841318",
          "K823026",
          "K812114",
          "K843254",
          "K822603",
          "K884307",
          "K842209",
          "K870317",
          "K821579",
          "K833953",
          "K840942",
          "K864789",
          "K874491",
          "K894487",
          "K834154",
          "K893487",
          "K935236",
          "K833682",
          "K842080",
          "K832702",
          "K874916",
          "K855000",
          "K864229",
          "K834106",
          "K862273",
          "K851058",
          "K832739",
          "K842210",
          "K870820",
          "K905498",
          "K153760",
          "K882167",
          "K880006",
          "K894111",
          "K896907",
          "K840644",
          "K801861",
          "K840823",
          "K760491",
          "K854863",
          "K811432",
          "K242693",
          "K905497",
          "K833520",
          "K232316",
          "K874481",
          "K823404",
          "K842419",
          "K812510",
          "K771158"
        ],
        "registration_number": [
          "3016798778",
          "3012429465",
          "1287243",
          "3007305485",
          "1223925",
          "3015192982",
          "1018470",
          "1220973",
          "1320894"
        ],
        "fei_number": [
          "3001451571",
          "3016798778",
          "3012429465",
          "1287243",
          "3007305485",
          "1000305720",
          "1018470",
          "1220973",
          "3015192982"
        ],
        "device_name": "Controller, Infusion, Intravascular, Electronic",
        "medical_specialty_description": "General Hospital",
        "regulation_number": "880.5725",
        "device_class": "2"
      }
    }
  ]
}