  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-11-26",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "158651",
      "product_res_number": "Z-3237-2017",
      "event_date_initiated": "2017-09-07",
      "event_date_created": "2017-09-29",
      "recall_status": "Terminated",
      "event_date_terminated": "2019-08-01",
      "res_event_number": "78097",
      "product_code": "JJS",
      "k_numbers": [
        "K980135"
      ],
      "product_description": "AutoCheck5+, Level 2, specifically designed for Radiometer Americas blood gas analyzers\nThe QUALICHECK+ quality control (QC) ampoules are specifically designed for Radiometer America s blood gas analyzers",
      "code_info": "S7745 Lot R0698",
      "firm_fei_number": "3010420736",
      "recalling_firm": "Radiometer America Inc",
      "address_1": "250 S Kraemer Blvd",
      "city": "Brea",
      "state": "CA",
      "postal_code": "92821-6232",
      "additional_info_contact": "Technical Support\n800-736-0600 Ext. 1",
      "reason_for_recall": "Radiometer has recently become aware that a few of the AUTOCHECK 5+ level 2 ampoules, will give incorrect results for pCO2 and pO2.\nA defective QC ampoule will for:\n\" pCO2 give a result close to or just outside of the low end of the control range. (4.92  5.85 kPa or 36.9  46.9 mmHg)\n\" pO2 give a considerable higher result than the expected assigned value of 13.9 -14.3 kPa (104-107 mmHg)",
      "root_cause_description": "Under Investigation by firm",
      "action": "Radiometer sent a Safety Notice dated September 7, 2017, to all affected customers.  The firm initiated their recall on 09/07/2017 by email.  \n\nThe letter requested the following:\n\n1. Please check your inventory and analyzers for any boxes and ampoules of above mentioned QC.\n2. Discard all Boxes and ampoules of this lot.\n3. Complete the response form and return it to the number on the form.\n\nPlease note:\nIf you are not the end-user of the affected product, please ensure that this letter is distributed to the final end-user.\nCustomers with questions were advised to contact their Radiometer representative.",
      "product_quantity": "1669 Boxes",
      "distribution_pattern": "Worldwide Distribution - US (nationwide) Internationally to Canada, Netherlands, China, Czech Republic, Denmark, Germany, Spain\nFrance, Hungary, India, Denmark, Tokyo, South Korea, United Kingdom, Australia, Poland, South Africa, Singapore, Switzerland, Turkey, Norway, Austria, Italy, Sweden, and Finland.",
      "openfda": {
        "k_number": [
          "K972861",
          "K770950",
          "K894110",
          "K952477",
          "K033063",
          "K820319",
          "K950902",
          "K811143",
          "K946224",
          "K003239",
          "K872196",
          "K812601",
          "K791287",
          "K901986",
          "K832003",
          "K874408",
          "K002866",
          "K130415",
          "K770228",
          "K792180",
          "K961354",
          "K851911",
          "K955340",
          "K812541",
          "K904733",
          "K002536",
          "K833146",
          "K922357",
          "K152553",
          "K022525",
          "K810107",
          "K002120",
          "K003242",
          "K980135",
          "K830181",
          "K915399",
          "K923342",
          "K820873",
          "K780144",
          "K771044",
          "K792098",
          "K002535",
          "K920285",
          "K790813",
          "K841783",
          "K022529",
          "K792143",
          "K820705",
          "K801449",
          "K935515",
          "K945860",
          "K855024",
          "K952637",
          "K150226",
          "K961441",
          "K901985",
          "K961355",
          "K870036",
          "K820103",
          "K002865",
          "K812553",
          "K781421",
          "K130236",
          "K771444",
          "K901976",
          "K792447",
          "K832028"
        ],
        "registration_number": [
          "3010127294",
          "3023162659",
          "3003971136",
          "2016706",
          "3011325031",
          "3002637618",
          "1222035",
          "1827821",
          "3003030793",
          "9681518",
          "3004493545",
          "2432235",
          "1220649",
          "3006198300",
          "1219029",
          "3005333358",
          "9610746",
          "3002807968",
          "3013513377"
        ],
        "fei_number": [
          "3010127294",
          "3023162659",
          "3003971136",
          "2016706",
          "3011325031",
          "3002637618",
          "1222035",
          "1827821",
          "3003030793",
          "3002806557",
          "3004493545",
          "2432235",
          "1220649",
          "3005695774",
          "3006198300",
          "1219029",
          "3005333358",
          "3002807968",
          "3013513377"
        ],
        "device_name": "Controls For Blood-Gases, (Assayed And Unassayed)",
        "medical_specialty_description": "Clinical Chemistry",
        "regulation_number": "862.1660",
        "device_class": "1"
      }
    }
  ]
}