  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-11-26",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 3
    }
  },
  "results": [
    {
      "cfres_id": "115819",
      "product_res_number": "Z-0951-2013",
      "event_date_initiated": "2013-01-28",
      "event_date_posted": "2013-03-14",
      "recall_status": "Terminated",
      "event_date_terminated": "2013-07-19",
      "res_event_number": "64320",
      "product_code": "GJT",
      "k_numbers": [
        "K962675"
      ],
      "product_description": "Vial Label:\n\n1) LIATEST VWF:Ag Buffer - 5 ml Diagnostica Stago\n\n2) LIATEST VWF:Ag Latex + 4 ml R3 Diagnostica Stago\n\n3) LIATEST VWF:Ag Latex Diluent 4 mL Diagnostica Stago\n\nModel, catalogue, number 00518  - 58978 - 58979\n\nKit Label:\n\nLIATEST VWF:Ag\nDIAGNOSTICA STAGO S.A.S.\n92600 Asnires sur Seine (France)\n\nCoagulation Assay",
      "code_info": "Lot/Unit Numbers : Combination of All STA-R¿/ STA-R EVOLUTION¿  and lots of STA¿ - LIATEST¿ VWF: AG are involved.     Lot Number Expiry date 108128\t2013-03 108512\t2013-04 108778\t2013-07 109415\t2013-10 109591\t2014-01",
      "firm_fei_number": "2245451",
      "recalling_firm": "Diagnostica Stago, Inc.",
      "address_1": "5 Century Dr",
      "city": "Parsippany",
      "state": "NJ",
      "postal_code": "07054-4607",
      "additional_info_contact": "Stago Hotline\n800-725-0607",
      "reason_for_recall": "Diagnostica Stago has confirmed that sometimes the delta OD measured can be changed leading to a lowered percentage result.",
      "root_cause_description": "Software design (manufacturing process)",
      "action": "Diagnostica Stago Inc. sent e-mail notifications on 1/28/2013 to all consignees (laboratory supervisor).  The written field safety notice, entitled Important Field Safety Notice, with its response form was attached.  The letter identified the affected product and gave a description of the defect.  Customers were asked to confirm all the results obtained in the abnormal range by either of the two methods provided.  Users are to complete and return the enclosed response form as soon as possible to the Stago Hotline via fax, 973-644-9348.  Questions should be directed to the Stago Hotline at 800-725-0607.",
      "product_quantity": "2901 kits",
      "distribution_pattern": "Worldwide Distribution - USA and Canada.",
      "openfda": {
        "k_number": [
          "K023839",
          "K030287",
          "K912679",
          "K942050",
          "K031122",
          "K895504",
          "K981173",
          "K971223",
          "K900411",
          "K900407",
          "K971225",
          "K934605",
          "K180486",
          "K924396",
          "K935054",
          "K893524",
          "K962675",
          "K893525",
          "K924394",
          "K924400",
          "K933440",
          "K900410",
          "K962671",
          "K915411",
          "K222831",
          "K900406",
          "K935056",
          "K933438",
          "K893535",
          "K102908",
          "K935850",
          "K900133",
          "K880874",
          "K883692",
          "K902083",
          "K933441",
          "K972286",
          "K880292",
          "K990296",
          "K942049",
          "K900906",
          "K990046",
          "K933444",
          "K900409",
          "K883691",
          "K934606",
          "K981174",
          "K040362",
          "K901327",
          "K893534",
          "K031829",
          "K050661",
          "K900412",
          "K895503",
          "K970607",
          "K893533",
          "K933010",
          "K945857",
          "K883688",
          "K971224",
          "K110237",
          "K883690",
          "K024082",
          "K990814",
          "K970593",
          "K893536",
          "K893523",
          "K981709",
          "K043459",
          "K971227",
          "K935851",
          "K900408",
          "K933432",
          "K971226",
          "K102851",
          "K935057",
          "K034007",
          "K935058",
          "K972627"
        ],
        "registration_number": [
          "9610806",
          "3008386529",
          "2431530",
          "2245451",
          "1181121",
          "9710666",
          "1835316",
          "1928890",
          "3037000637",
          "8043599",
          "1530434"
        ],
        "fei_number": [
          "3003565434",
          "3008386529",
          "3000719074",
          "3005917516",
          "2431530",
          "2245451",
          "3000210416",
          "3001644026",
          "1181121",
          "1928890",
          "3037000637"
        ],
        "device_name": "Plasma, Coagulation Factor Deficient",
        "medical_specialty_description": "Hematology",
        "regulation_number": "864.7290",
        "device_class": "2"
      }
    }
  ]
}