      "cfres_id": "162052",
      "product_res_number": "Z-0824-2018",
      "event_date_initiated": "2017-12-15",
      "event_date_created": "2018-03-01",
      "recall_status": "Terminated",
      "event_date_terminated": "2020-04-23",
      "res_event_number": "79336",
      "product_code": "FWB",
      "product_description": "Camera System, Television, Surgical without audio\n\nIntended for transmission and documentation of surgical interventions for the purpose of archiving and teaching.",
      "code_info": "Catalog Number 1940747, All serial numbers: 102584474, 102584475, 102584477, 102584478, 102805330, 102813656, 102813657, 102813658, 102813659, 102813660, 102813661, 102813662, 102860647, 102860652, 102863706, 102863707, 102867783, 102867784, 102925734, 102925735, 102925736, 102925737, 102925738, 102925739, 102925740, 102925741, 102925742, 102925743, 102928703, 102932185, 102932186, 102932187, 102932188, 102932189, 102932203, 102932204, 102932205, 102932206, 102932207, 102932208, 102932209, 102932210, 102932211, 102932212, 102932217, 102932218, 102932219, 102932220, 102932221, 102932223, 102934525, 102934526, 102934527, 102934528, 102934529, 102936117, 102939484, 102940382, 102940383, 102940384, 102940386, 102940387, 102940388, 102940389, 102940390, 102940391, 102940408, 102940409, 102940410, 102961390, 102961391, 102961392, 102961393, 102961394, 102961395, 102961396, 102961397, 102961398, 102961399, 102961400, 102961401, 102975336, 102986494, 102986495, 102988480, 102989096, 102989607, 102989608, 102989615, 102990285, 102990286, 102994502, 102994503, 102994504, 102994505, 102994506, 102994525, 102994526, 102994529, 102994530, 102996306, 103005879, 103005880, 103005889, 103005890, 103005891, 103005892, 103005893, 103006636, 103010023, 103010759, 103010760, 103010761, 103010762, 103010763, 103012786, 103012787, 103013644, 103017040, 103017041, 103019900, 103020713, 103022348, 103022349, 103022350, 103022351, 103022352, 103022794, 103024049, 103024050, 103030284, 103031623, 103034106, 103034109, 103038842, 103038843, 103038844, 103038845, 103038846, 103038847, 103038848, 103038849, 103038850, 103038853, 103038854, 103038855, 103038856, 103038857, 103038858, 103038859, 103038860, 103038861, 103038862, 103038863, 103038864, 103038865, 103038866, 103039468, 103042319, 103042320, 103042321, 103042322, 103042925, 103042926, 103046119, 103046120, 103046121, 103046122, 103046123, 103046124, 103046125, 103046126, 103046127, 103046128, 103046129, 103046130, 103048248, 103065061, 103070795, 103070796, 103070797, 103070798, 103079001, 103079053, 103087365, 103087366, 103087367, 103087368, 103087369, 103087370, 103087371, 103090135, 103090136, 103090137, 103091507, 103091508, 103091509, 103091510, 103091511, 103095664, 103101676, 103101826, 103101864, 103101886, 103103841, 103103842, 103103843, 103103844, 103103845, 103104556, 103113059, 103117961, 103118986, 103118987, 103118988, 103118989, 103118990, 103118991, 103118992, 103118993, 103118994, 103118995, 103123759, 103133224, 103134656, 103138822, 103143214, 103149993, 103164298, 103168053, 103168341, 103168431, 103176559, 103176571, 103176574, 103191728, 103191729, 103194419, 103214005, 103214022.",
      "firm_fei_number": "3003184737",
      "recalling_firm": "Trumpf Medical Systems, Inc.",
      "address_1": "1046 Legrand Blvd",
      "city": "Charleston",
      "state": "SC",
      "postal_code": "29492-7672",
      "additional_info_contact": "Chandler Sprinkles \n843-329-0543",
      "reason_for_recall": "The radiated emission from the TruVidia\" Wireless Receiver is above the normative accepted limits, in which the radiated emission may interact with other devices in the operating room and cause them not to function properly.",
      "root_cause_description": "Other",
      "action": "Trumpf Medical Systems sent an Urgent Medical Device Correction letter  dated December 15, 2017.  Instructions include to complete and return the Confirmation of Receipt, arrange for the Trumpf Medical Engineer or an authorized Service Engineer to upgrade the affected device, and ensure that all users of the device are aware of the recall. For further questions, please call  (843) 329-0543",
      "product_quantity": "212 devices",
      "distribution_pattern": "Worldwide Distribution - US Distribution to the states of : GA, IL, IN, PA, SC, TX, UT, VA.   and to the countries of :  Austria, Australia, Bangladesh, Belgium, France, Switzerland, Czech Republic, Germany, Denmark, Spain, United Arab Emirates, United Kingdom, Ireland, Italy, Kuwait, Lithuania, Poland, Portugal, Romania, Sweden, Slovenia, Thailand, Turkey.",
      "openfda": {
        "k_number": [
          "K820829",
          "K902359",
          "K871057",
          "K934092",
          "K855020",
          "K884343"
        ],
        "registration_number": [
          "3019269298",
          "3021226419",
          "3008040391",
          "3000160970",
          "3021393544",
          "3020899789",
          "3003542872",
          "1220246",
          "3002579136",
          "3014262693",
          "3016851379",
          "3021336182",
          "3030548301",
          "3013501671",
          "3010399422",
          "3006990600",
          "3016727307",
          "3010400367",
          "3031238646",
          "3004578804",
          "3010331645",
          "3012818475",
          "1037039",
          "3021839632",
          "3005698350",
          "3010043098",
          "3004434200",
          "3012329552",
          "3005778609",
          "3015532816",
          "3014004349",
          "2936485",
          "3016696283",
          "1000122786",
          "3006810260"
        ],
        "fei_number": [
          "3019269298",
          "3021226419",
          "3008040391",
          "3000160970",
          "3021393544",
          "3020899789",
          "1000125341",
          "3003542872",
          "1220246",
          "3002579136",
          "3014262693",
          "3016851379",
          "3021336182",
          "3030548301",
          "3013501671",
          "3010399422",
          "3006990600",
          "3016727307",
          "3010400367",
          "3031238646",
          "3004578804",
          "3010331645",
          "3012818475",
          "1037039",
          "3005698350",
          "3010043098",
          "3004434200",
          "3012329552",
          "3005778609",
          "3015532816",
          "3014004349",
          "2936485",
          "3016696283",
          "1000122786",
          "3006810260"
        ],
        "device_name": "Camera, Television, Surgical, Without Audio",
        "medical_specialty_description": "General, Plastic Surgery",
        "regulation_number": "878.4160",
        "device_class": "1"
      }
    }
  ]
}