  "results": [
    {
      "cfres_id": "30444",
      "product_res_number": "Z-0247-04",
      "event_date_initiated": "2003-10-10",
      "event_date_posted": "2003-12-18",
      "recall_status": "Terminated",
      "event_date_terminated": "2016-01-28",
      "res_event_number": "27738",
      "product_code": "FEM",
      "product_description": "Smith & Nephew  Endocoupler C-Mount 30mm Focal Length\nReference: 7204823 and 7204823S (S indicates unit previously serviced)",
      "code_info": "Part Number: 7204823, Camera Coupler, C-Mount, 30mm F.L. \tSerial Numbers (SR prefix):  8632\t8646\t8652\t8659\t8670\t8679\t8693\t8709\t8714 8633\t8647\t8655\t8660\t8675\t8686\t8694\t8711\t8716 8635\t8648\t8657\t8665\t8676\t8687\t\t8712\t8727 8636\t8649\t8658\t8668\t8677\t8691\t8707\t8713\t8728  Part Number: 7204823S, Camera Coupler, C-Mount, 30mm F.L. Serial Number SR8705",
      "firm_fei_number": "3003604053",
      "recalling_firm": "Smith And Nephew, Inc. Endoscopy Division",
      "address_1": "150 Minuteman Rd",
      "city": "Andover",
      "state": "MA",
      "postal_code": "01810-1031",
      "additional_info_contact": "Jason Bilobram\n978-474-6332",
      "reason_for_recall": "Hardware of the camera coupler may rust and result in an ineffective sterilization/cleaning process.",
      "root_cause_description": "Nonconforming Material/Component",
      "action": "Smith & Nephew notified direct accounts by letter on 10/15/03.  Service representatives will remove and replace product.",
      "product_quantity": "35 units",
      "distribution_pattern": "Nationwide to hospitals\nForeign: Australia, Africa, Belgium, Canada, China, Dubai, Egypt, Germany, D\\Godmanchester, Italy, Japan, Korea, Malaysia, Norway, Portugal, Singapore, South Africa, Thailand, Taiwan.",
      "openfda": {
        "k_number": [
          "K812542",
          "K792512",
          "K940152",
          "K812201"
        ],
        "registration_number": [
          "",
          "2124215",
          "3012883081",
          "3013831261",
          "3011459664",
          "3004443374",
          "3019530907",
          "1017294",
          "3021226419",
          "3014342096",
          "3008494403",
          "3012843412",
          "3016436764",
          "8030607",
          "3016050940",
          "1220246",
          "3011373951",
          "3003782610",
          "2027009",
          "3012797688",
          "3016045249",
          "3021393544",
          "9611102",
          "3010202439",
          "3010399422",
          "9610877",
          "9610617",
          "8010047",
          "3010331645",
          "2938071",
          "2936485",
          "1418479",
          "2183911",
          "9611112",
          "1221934",
          "3008953712",
          "3021336182",
          "3042225166",
          "1225968",
          "9611174",
          "3014498758",
          "3003775006",
          "3008114965",
          "3034676720",
          "3005099803",
          "3001556604",
          "3001644167",
          "3033043422",
          "1836161",
          "1833053",
          "1222773",
          "8043980",
          "3027655341",
          "3002808148",
          "3019512034",
          "3015168749",
          "9610612",
          "2085947",
          "3030926959",
          "3012447612",
          "3006161756",
          "1222616",
          "9610691"
        ],
        "fei_number": [
          "",
          "2124215",
          "1000120916",
          "3012883081",
          "3013831261",
          "3011459664",
          "3004443374",
          "3002807795",
          "3019530907",
          "1017294",
          "3021226419",
          "3014342096",
          "3008494403",
          "3012843412",
          "3016436764",
          "1000120768",
          "3016050940",
          "1220246",
          "3011373951",
          "3003782610",
          "2027009",
          "3012797688",
          "3016045249",
          "1000162602",
          "3021393544",
          "3000204191",
          "3010399422",
          "3010331645",
          "2938071",
          "2936485",
          "1418479",
          "3008782585",
          "1221934",
          "3008953712",
          "3021336182",
          "3042225166",
          "3014498758",
          "3003775006",
          "3008114965",
          "3034676720",
          "3002806315",
          "3002750084",
          "3008185830",
          "3005099803",
          "3001556604",
          "1000116142",
          "3001644167",
          "3002480801",
          "3033043422",
          "1833053",
          "3002808268",
          "3002808001",
          "3002806359",
          "3019512034",
          "3002808127",
          "3002808148",
          "3027655341",
          "3007475226",
          "3015168749",
          "3002914049",
          "3030926959",
          "3012447612",
          "3006509795"
        ],
        "device_name": "Accessories, Photographic, For Endoscope (Exclude Light Sources)",
        "medical_specialty_description": "Gastroenterology, Urology",
        "regulation_number": "876.1500",
        "device_class": "1"
      }
    }
  ]
}