  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-11-26",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 2
    }
  },
  "results": [
    {
      "cfres_id": "145360",
      "product_res_number": "Z-2075-2016",
      "event_date_initiated": "2016-04-06",
      "event_date_posted": "2016-06-28",
      "recall_status": "Terminated",
      "event_date_terminated": "2017-12-21",
      "res_event_number": "73894",
      "product_code": "FAM",
      "k_numbers": [
        "K951572",
        "K951577"
      ],
      "product_description": "Signmoidoscope\nIntended to provide optical visualization of, therapeutic access to, the Lower Gastrointestinal Tract. This anatomy includes, but is not restricted to, the organs, tissues and subsystems: Large Bowel to the Sigmoid Colon. The instrument is introduced via the rectum when indications consistent with the need for procedure are observed in adult and pediatric patient populations",
      "code_info": "Model #'s FS-34V, ES-3831, ES-3870K and ES-3840",
      "firm_fei_number": "1000080301",
      "recalling_firm": "Pentax Medical Company",
      "address_1": "3 Paragon Dr",
      "city": "Montvale",
      "state": "NJ",
      "postal_code": "07645-1782",
      "additional_info_contact": "Mr. Paul Silva\n800-431-5880 Ext. 2064",
      "reason_for_recall": "Pentax has become aware that operational/cleaning accessories and therapeutic devices (e.g., clips, stents, balloons, etc.) can become lodged in an endoscope's instrument channel.",
      "root_cause_description": "Device Design",
      "action": "Pentax sent an Urgent Field Correction letter dated April 6, 2016 to all affected consignees.  The letter identified the product, the problem, and the action to be taken by the consignee.  Consignees were reminded to carefully check that all accessories are intact, that no parts have fallen off and become lodged within the endoscope's instrument/suction channel and to ensure that any therapeutic devices passed through the instrument channel are accounted for after use.  If the instrument/suction channel does become blocked or clogged due to the accumulation of debris, an accessory that cannot be removed, or other cause, do NOT attempt to correct the blockage or continue to use the endoscope.  Customers were instructed to contact their local PENTAX Medical Service facility to have the endoscope repaired.  Customers with questions were instructed to call 800-431-5880, ext 2064.",
      "product_quantity": "1,596 units",
      "distribution_pattern": "Worldwide Distribution - US (Nation Wide) including Puerto Rico and Internationally to Denmark, Guam",
      "openfda": {
        "k_number": [
          "K770291",
          "K964131",
          "K932843",
          "K950429",
          "K792314",
          "K951577",
          "K970382",
          "K771815",
          "K964100",
          "K790610",
          "K961567",
          "K951572",
          "K812965",
          "K792341",
          "K892000",
          "K760173",
          "K951573",
          "K951576",
          "K964326",
          "K921690",
          "K761180",
          "K963344",
          "K820790",
          "K822765"
        ],
        "device_name": "Sigmoidoscope And Accessories, Flexible/Rigid",
        "medical_specialty_description": "Gastroenterology, Urology",
        "regulation_number": "876.1500",
        "device_class": "2",
        "registration_number": [
          "3042225166",
          "3010202439",
          "3014579161",
          "3010405378",
          "3006546082",
          "1221826",
          "3013298431",
          "3004040397",
          "1055236",
          "2320762",
          "1316463",
          "2020550",
          "3012494290",
          "3014342096",
          "1054241",
          "3012421607",
          "3014605202",
          "9610877",
          "3004644065",
          "3013557562",
          "3004450489",
          "9610691",
          "3006161756",
          "1043214",
          "3003782610",
          "3001124136",
          "3000268902",
          "9611112",
          "9610617",
          "3010707607"
        ],
        "fei_number": [
          "3042225166",
          "3003040625",
          "3002808268",
          "3014579161",
          "3010405378",
          "3006546082",
          "1221826",
          "3013298431",
          "3004040397",
          "1316463",
          "2020550",
          "3012494290",
          "3014342096",
          "3002808127",
          "3012421607",
          "3002806359",
          "3014605202",
          "3007475226",
          "3004644065",
          "3013557562",
          "3004450489",
          "1000112877",
          "1000112968",
          "1043214",
          "3003782610",
          "3001124136",
          "3000268902",
          "3010707607",
          "3008185830",
          "3008782585"
        ]
      }
    }
  ]
}