  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-11-26",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 2
    }
  },
  "results": [
    {
      "cfres_id": "51066",
      "product_res_number": "Z-1105-2007",
      "event_date_initiated": "2004-10-12",
      "event_date_posted": "2007-08-02",
      "recall_status": "Terminated",
      "event_date_terminated": "2007-08-02",
      "res_event_number": "37614",
      "product_code": "DWQ",
      "k_numbers": [
        "K032387"
      ],
      "product_description": "Smith & Nephew TRIVEX System Pneumatic Footswitch, Part #7209791; distributed by Smith & Nephew, Inc. - Endoscopy, Andover, MA  01810.",
      "code_info": "Pnuematic Footswitch part of TRIVEX System with the following serial numbers: 105, 106, 108, 109, 111 -123, 125 - 182, 184 - 188, 192 - 197, 199 - 203, 205 - 219, 222 - 249, 252 - 254, and 7210386.",
      "firm_fei_number": "1643264",
      "recalling_firm": "Smith & Nephew, Inc Endoscopy Division",
      "address_1": "76 S. Meridian Ave",
      "city": "Oklahoma City",
      "state": "OK",
      "postal_code": "73107-6512",
      "reason_for_recall": "Build-up of static charge in Pneumatic Footswitch tubing may cause control unit to reset to default settings in the operating room during surgery.",
      "root_cause_description": "Other",
      "action": "Firm sent notification letters to consignees via overnight FedEx on 10/12-13/04.  International customers were notified via letter on 11/10/04.  Customers were asked to return footswitches for a replacement.",
      "product_quantity": "274 units.",
      "distribution_pattern": "Product sent to distributors nationwide and to the following countries:  Australia, Austria, Canada, China, Germany, Italy, Japan, and Taiwan.",
      "openfda": {
        "k_number": [
          "K041453",
          "K811910",
          "K904507",
          "K885046",
          "K872157",
          "K905528",
          "K212894",
          "K032387"
        ],
        "registration_number": [
          "3011137372",
          "8040233",
          "2523676",
          "1319639",
          "3010041511",
          "1220948",
          "9710524",
          "3045042524"
        ],
        "fei_number": [
          "3005747797",
          "2523676",
          "3003944071",
          "3010041511",
          "1220948",
          "3045042524",
          "1000138054",
          "3003499455"
        ],
        "device_name": "Stripper, Vein, External",
        "medical_specialty_description": "Cardiovascular",
        "regulation_number": "870.4885",
        "device_class": "2"
      }
    }
  ]
}