  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-11-26",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "171518",
      "product_res_number": "Z-1194-2019",
      "event_date_initiated": "2019-03-18",
      "event_date_created": "2019-04-18",
      "recall_status": "Terminated",
      "event_date_terminated": "2020-08-28",
      "res_event_number": "82388",
      "product_code": "CJW",
      "k_numbers": [
        "K844426"
      ],
      "product_description": "Albumin BCP \n\nProduct Usage:  ALBP is an in vitro test used for the quantitative determination of albumin in human serum and plasma on Roche/Hitachi cobas c systems.",
      "code_info": "Catalog Number 05975573190 Lot Number 35651401",
      "firm_fei_number": "1823260",
      "recalling_firm": "Roche Diagnostics Corporation",
      "address_1": "9115 Hague Rd",
      "city": "Indianapolis",
      "state": "IN",
      "postal_code": "46256-1025",
      "additional_info_contact": "317-5214343",
      "reason_for_recall": "The reagent lot is exhibiting calibration failures, QC imprecision, and elevated QC recovery due to elevated pH level causing higher absorbance values.",
      "root_cause_description": "Process control",
      "action": "Urgent Medical Device Correction notification letters dated 3/18/19 were sent to customers.  The letter identified the affected product, problem and actions to be taken.  The letter instructed customers to:\n\nStop using and discard all Albumin BCP reagent cassettes from lot number 35651401 (catalog number 05975573190) remaining in your inventory according to your local guidelines.\n\nActions Required\n\" Complete all sections of the enclosed fax form and fax it to 1-833-254-2600 or email it to\nRoche10060@stericycle.com even if you are not requesting product replacement.\n\" Discard remaining affected product in your inventory according to local guidelines.\n\" File this Urgent Medical Device Correction (UMDC) for future reference.",
      "product_quantity": "774",
      "distribution_pattern": "US Nationwide distribution in the states of: GA, IL, KY, MI, and TX.",
      "openfda": {
        "k_number": [
          "K132664",
          "K021636",
          "K863004",
          "K981457",
          "K844426",
          "K863226",
          "K000483",
          "K913025",
          "K842847",
          "K860423",
          "K905776",
          "K830934",
          "K862138",
          "K990978",
          "K193001",
          "K832632",
          "K203530",
          "K981814"
        ],
        "device_name": "Bromcresol Purple Dye-Binding, Albumin",
        "medical_specialty_description": "Clinical Chemistry",
        "regulation_number": "862.1035",
        "device_class": "2",
        "registration_number": [
          "9680746",
          "8020888",
          "1317202",
          "2517506",
          "2030861",
          "1181121",
          "1219913",
          "3005094123",
          "9681753",
          "3002809144",
          "3016438761",
          "2432235",
          "3011989923",
          "3006198300",
          "3003795116",
          "9610126",
          "3021841051",
          "1319809",
          "3005333358",
          "2939693",
          "3010825766",
          "2050010",
          "9610529",
          "2050012"
        ],
        "fei_number": [
          "1317202",
          "2517506",
          "1181121",
          "1219913",
          "3005094123",
          "1000206808",
          "3002806559",
          "3002809144",
          "3016438761",
          "2432235",
          "3011989923",
          "3007019572",
          "3006198300",
          "3003795116",
          "3021841051",
          "3005333358",
          "3002806560",
          "2939693",
          "3010825766",
          "2050010",
          "1000305840",
          "3000215862",
          "3000303338",
          "2050012"
        ]
      }
    }
  ]
}