{
  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-11-26",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 7
    }
  },
  "results": [
    {
      "cfres_id": "215487",
      "product_res_number": "Z-0032-2026",
      "event_date_initiated": "2025-08-04",
      "event_date_posted": "2025-10-02",
      "recall_status": "Open, Classified",
      "res_event_number": "97390",
      "product_code": "CGR",
      "k_numbers": [
        "K242190"
      ],
      "product_description": "DxC 500 AU Module w/ISE, DxC 500i, With ISE, REF: C63522 and DxC 500 AU Module, DxC 500i, Without ISE, REF: C6352; part of the DxC 500i Clinical Analyzer",
      "code_info": "REF/UDI-DI:\nC63522/14987666545089, C63521/14987666545072.\nSoftware Versions: SW 1.3.3 and 1.3.4",
      "firm_fei_number": "2050012",
      "recalling_firm": "Beckman Coulter Inc.",
      "address_1": "250 S Kraemer Blvd",
      "city": "Brea",
      "state": "CA",
      "postal_code": "92821-6232",
      "additional_info_contact": "714-961-5321",
      "reason_for_recall": "On a clinical analyzer, when ordering a Clinical Chemistry (CC) combination test simultaneously with an Immunoassay (IA) test, if the IA test is processed between the CC tests, CC sample status will remain In Progress with no errors, may cause processing delays.",
      "root_cause_description": "Software Design Change",
      "action": "On 8/4/2025, recall notices were mailed and/or emailed to customers who were asked to do the following:\nCheck your software version, select Menu - About page.\n- For Clinical Analyzers running software version 1.3.3 or 1.3.4, if this issue occurs, you will need to place a new order for the CC combination test,\n- Select Home - Sample List task indicator, then select Active in the upper left corner of the Sample List to display samples \"In Progress\".\n- Program the CC combination tests for these \"In Progress\" samples using a new rack and Sample ID, apply the new barcode, then load the rack onto the analyzer for processing.\n- Set aside the rack with \"In Progress\" samples and contact your Beckman Coulter representative to clear them.\n\nFirm recommends sharing the content of this letter with your laboratory and/or Medical Director.\n\nFirm has resolved this issue in Software version 1.3.5 and a firm service representative will contact you to schedule the software upgrade.\n\nShare this information with your laboratory staff and retain this notification as part of your laboratory Quality System documentation. If you have forwarded any of the affected product(s) listed above to another laboratory, please provide them a copy of this letter.\n\nComplete and return the response form via email to: regaffairsfax@beckman.com\n\nIf you have any questions regarding this product, please contact your local firm representative, or use the following link for a listing of local contact information.\nhttps://www.beckmancoulter.com/en/support/contact-us",
      "product_quantity": "116",
      "distribution_pattern": "Internationally distribution to the countries of Poland, India, Dominican Republic, Lebanon, Italy, Brazil, El Salvador, Saudi Arabia, Germany, France, Nepal, Canada, Chile, Spain, Malaysia, Switzerland, Morocco, Philippines, Curacao, Qatar, United Arab Emirates, Hungary, Czechia, Oman, New Zealand, Thailand, Indonesia, Algeria, United Kingdom of Great Britain and Northern Ireland, Namibia, Turkey, Republic of Korea",
      "openfda": {
        "k_number": [
          "K843183",
          "K760939",
          "K850008",
          "K830148",
          "K790906",
          "K052359",
          "K922676",
          "K862871",
          "K223038",
          "K810033",
          "K800245",
          "K943427",
          "K870969",
          "K761346",
          "K841641",
          "K781903",
          "K800045",
          "K781730",
          "K062626",
          "K810891",
          "K895006",
          "K900485",
          "K852939",
          "K843384",
          "K802380",
          "K800700",
          "K842365",
          "K901296",
          "K984520",
          "K842554",
          "K050202",
          "K792439",
          "K792036",
          "K872177",
          "K905473",
          "K903975",
          "K801203",
          "K760256",
          "K242190",
          "K931409",
          "K060480",
          "K880687",
          "K010790",
          "K945367",
          "K800594",
          "K203270",
          "K792243",
          "K202826",
          "K820074",
          "K791700",
          "K831141",
          "K830563",
          "K822892",
          "K820341",
          "K884689",
          "K962208",
          "K822845",
          "K895407",
          "K821931",
          "K931177",
          "K940221",
          "K954733",
          "K821068",
          "K810192",
          "K850141",
          "K782110",
          "K842957",
          "K800538",
          "K802969",
          "K202136",
          "K914886",
          "K042689",
          "K842455",
          "K862336",
          "K791835",
          "K802036",
          "K840466",
          "K896451",
          "K780725",
          "K832638",
          "K771117",
          "K834219",
          "K790268",
          "K983990"
        ],
        "device_name": "Radioimmunoassay, Cortisol",
        "medical_specialty_description": "Clinical Chemistry",
        "regulation_number": "862.1205",
        "device_class": "2",
        "registration_number": [
          "3011989923",
          "3000308930",
          "1036362",
          "3022178699",
          "2245285",
          "2122870",
          "3002800697",
          "2020726",
          "3006198300",
          "9612296",
          "3002642396",
          "3007111389",
          "3007118747",
          "3002806944",
          "3012963943",
          "1319681",
          "2250051",
          "8021924"
        ],
        "fei_number": [
          "3011989923",
          "3000308930",
          "1036362",
          "3022178699",
          "2245285",
          "3002807663",
          "3002800697",
          "2122870",
          "3006198300",
          "3002642396",
          "3007111389",
          "2020726",
          "3007118747",
          "3002485711",
          "3002806944",
          "1000136573",
          "3012963943",
          "2250051"
        ]
      }
    }
  ]
}