  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-11-21",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 4
    }
  },
  "results": [
    {
      "cfres_id": "206845",
      "product_res_number": "Z-1616-2024",
      "event_date_initiated": "2024-03-22",
      "event_date_posted": "2024-04-23",
      "recall_status": "Open, Classified",
      "res_event_number": "94291",
      "product_code": "LOF",
      "pma_numbers": [
        "P850022"
      ],
      "product_description": "Biomet SpinalPak Non-invasive Spine Fusion Stimulator System- Indicated\nfor the treatment of an established nonunion acquired secondary to trauma,\nexcluding vertebrae and all flat bones,\nPart Number: 1067716",
      "code_info": "UDI-DI: 00812301020218\nAll devices distributed since May 1, 2023",
      "firm_fei_number": "2242816",
      "recalling_firm": "EBI, LLC",
      "address_1": "1 Gatehall Dr Ste 303 1 Gatehall Dr",
      "address_2": "Ste 303",
      "city": "Parsippany",
      "state": "NJ",
      "postal_code": "07054-4514",
      "additional_info_contact": "Customer Service\n800-526-2579 Ext. 60000",
      "reason_for_recall": "Damage to the lead wire sheath (black cable) component and causing exposure of the wires, potentially lead to no therapeutic treatment signal being delivered to the electrodes, and result in delay of treatment",
      "root_cause_description": "Device Design",
      "action": "ZimVie issued Urgent Medical Device Correction letter to Patients, Physicians, Sales Representatives on 3/22/24 . Letter states reason for recall, health risk and action to take:\n1. Review this notification for awareness of the contents.\n2. Before each use, inspect your device s lead wires (black cable) for damage. If found to be\ndamaged, contact Customer Service at 1-800-526-2579 x 6000 for a complimentary\nreplacement.\n3. Complete the Acknowledgement and Receipt Form either by scanning the QR code on the\npostcard included with this letter and completing the online form or mailing back the completed\npostcard. To complete your Acknowledgement, you will need to include your Unique Patient\nReference Number included on the top of the first page of this letter. This acknowledgement\nshould be completed even if you do not have affected product.\n4. If you have further questions or concerns after reviewing this notice, please call customer service\nat 1-800-526-2579 x 6000. Customer Service Representatives are available from 8:30 am to 5:00 pm (EST), Monday through Friday. At other times, please leave a clear message for a return call by the next business day. Alternatively, your questions may be emailed to ebi.csorders@zimvie.com.",
      "distribution_pattern": "US Nationwide distribution.",
      "openfda": {
        "k_number": [
          "K262721"
        ],
        "pma_number": [
          "P850022",
          "P230025",
          "P190030",
          "P030034",
          "P850007",
          "P210035",
          "P900009",
          "P790002",
          "P210016",
          "P910066"
        ],
        "registration_number": [
          "3016050940",
          "3010032952",
          "3013378804",
          "3012446970",
          "3030686063",
          "3009437400",
          "2242816",
          "3027669735",
          "1721293",
          "9611854",
          "3017264244",
          "3003435252",
          "3038295706",
          "3012447612",
          "2183449",
          "3007611554",
          "3009595577"
        ],
        "fei_number": [
          "3016050940",
          "3010032952",
          "3013378804",
          "3030686063",
          "3009437400",
          "2020737",
          "2242816",
          "3027669735",
          "3002807258",
          "1721293",
          "3017264244",
          "3003435252",
          "3038295706",
          "3012447612",
          "2183449",
          "3007611554",
          "3009595577"
        ],
        "device_name": "Stimulator, Bone Growth, Non-Invasive",
        "medical_specialty_description": "Orthopedic",
        "regulation_number": "890.5870",
        "device_class": "2"
      }
    }
  ]
}