  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-11-07",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "50798",
      "product_res_number": "Z-0014-2007",
      "event_date_initiated": "2006-11-06",
      "event_date_posted": "2007-09-26",
      "recall_status": "Terminated",
      "event_date_terminated": "2010-10-05",
      "res_event_number": "37567",
      "product_code": "KPS",
      "k_numbers": [
        "K010817",
        "K033326",
        "K033357"
      ],
      "product_description": "Brilliance(a) CT 6 slice, Model #4535 670 73191.  \nBrilliance(a) CT 10 Slice, Model 4535 670 73181.  \nBrilliance 16 Slice, Model #4535 670 78851.  \nBrilliance CT 16 Power, Model #4535 670 23331.  \nBrilliance CT 40 Slice, Model #4550 110 04011.  \nBrilliance  CT Big Bore, Model #4535 670 88051.  \n\nComputed tomography systems.",
      "code_info": "Serial #s  30035;  40022;  5059, 50027, 50017;  6011, 6095, 6118, 60006;   9145, 9036, 9115, 9089, 9042, 90061, 90109, 90072, 90050, 90150;  7022.",
      "firm_fei_number": "1525965",
      "recalling_firm": "Philips Medical Systems (Cleveland) Inc",
      "address_1": "595 Miner Road",
      "city": "Cleveland",
      "state": "OH",
      "postal_code": "44143-2131",
      "additional_info_contact": "George X. Kambic\n440-483-2557",
      "reason_for_recall": "A potential anomaly was identified on the CT subsytem, which could result in the radiation dose being different than the calculated dose reported to the operator.",
      "root_cause_description": "Other",
      "action": "The customers were sent Public Safety Notification November 3, 2006, indicating there was a problem with the software.  However, since their unit was recently upgraded the problem did not impact their unit.",
      "product_quantity": "20",
      "distribution_pattern": "Worldwide, including USA, Australia, Canada, China, England, Finland, France, Germany, Ireland, Israel, Italy, Japan, Jordan, Korea, Netherlands, Poland, Puerto Rico, Spain, and Taiwan.",
      "openfda": {
        "k_number": [
          "K210450",
          "K033735",
          "K913641",
          "K033199",
          "K162337",
          "K974256",
          "K083649",
          "K243186",
          "K992992",
          "K952674",
          "K983948",
          "K251153",
          "K121019",
          "K180077",
          "K032063",
          "K090811",
          "K991841",
          "K050815",
          "K991607",
          "K170904",
          "K070589",
          "K022872",
          "K973396",
          "K231731",
          "K033431",
          "K040326",
          "K171719",
          "K173547",
          "K953801",
          "K060631",
          "K250170",
          "K210557",
          "K062298",
          "K942146",
          "K081426",
          "K041022",
          "K942860",
          "K022001",
          "K142631",
          "K915644",
          "K923345",
          "K962100",
          "K051549",
          "K090553",
          "K010509",
          "K964834",
          "K922303",
          "K982911",
          "K040141",
          "K042880",
          "K011611",
          "K082904",
          "K850416",
          "K053086",
          "K050559",
          "K131625",
          "K072567",
          "K090403",
          "K953193",
          "K960865",
          "K003358",
          "K981352",
          "K911290",
          "K140651",
          "K021823",
          "K172609",
          "K202679",
          "K981553",
          "K964265",
          "K033874",
          "K140206",
          "K963162",
          "K153056",
          "K203314",
          "K221932",
          "K173023",
          "K170490",
          "K141971",
          "K182484",
          "K241596",
          "K925330",
          "K952564",
          "K032779",
          "K231748",
          "K896151",
          "K924498",
          "K001276",
          "K261305",
          "K113086",
          "K971878",
          "K243538",
          "K093514",
          "K970288",
          "K180318",
          "K963983",
          "K013496",
          "K052640",
          "K945261",
          "K083504",
          "K143664",
          "K251370",
          "K945652",
          "K181468",
          "K960192",
          "K201807",
          "K254001",
          "K042839",
          "K894998",
          "K982044",
          "K061587",
          "K991896",
          "K060020",
          "K052434",
          "K231762",
          "K140269",
          "K922372",
          "K253564",
          "K791055",
          "K040172",
          "K202349",
          "K980914",
          "K843366",
          "K952190",
          "K141477",
          "K041218",
          "K952684",
          "K152880",
          "K913471",
          "K023988",
          "K921777",
          "K991535",
          "K091073",
          "K111445",
          "K040616",
          "K051351",
          "K191582",
          "K002229",
          "K140996",
          "K970970",
          "K012775",
          "K993893",
          "K100714",
          "K033254",
          "K042863",
          "K992450",
          "K042903",
          "K013353",
          "K023768",
          "K964266",
          "K040370",
          "K213731",
          "K964267",
          "K942145",
          "K043441",
          "K013504",
          "K802801",
          "K980867",
          "K083852",
          "K101550",
          "K942363",
          "K233677",
          "K210262",
          "K112474",
          "K030085",
          "K212004",
          "K051460",
          "K946334",
          "K982387",
          "K041220",
          "K081453",
          "K062393",
          "K041166",
          "K123433",
          "K923309",
          "K911078",
          "K933446",
          "K770220",
          "K163394",
          "K123599",
          "K232712",
          "K892358",
          "K070542",
          "K922373",
          "K212604",
          "K920776",
          "K884349",
          "K261315",
          "K973233",
          "K243881",
          "K010137",
          "K003849",
          "K043381",
          "K994167",
          "K982045",
          "K891266",
          "K002584",
          "K002715",
          "K922426",
          "K261427",
          "K151486",
          "K022240",
          "K050509",
          "K943596",
          "K253844",
          "K151403",
          "K955484",
          "K862511",
          "K251839",
          "K982855",
          "K991318",
          "K172143",
          "K051170",
          "K992560",
          "K211964",
          "K211247",
          "K896458",
          "K223547",
          "K964268",
          "K161740",
          "K033956",
          "K992078",
          "K081135",
          "K974444",
          "K960948",
          "K965226",
          "K082368",
          "K180811",
          "K182938",
          "K080124",
          "K243605",
          "K030199",
          "K073021",
          "K042428",
          "K875378",
          "K954129",
          "K940300",
          "K963406",
          "K911275",
          "K172406",
          "K992317",
          "K913637",
          "K901019",
          "K920958",
          "K082354",
          "K181343",
          "K000908",
          "K040933",
          "K240827",
          "K121278",
          "K152503",
          "K193248",
          "K924877",
          "K964712",
          "K970128",
          "K080575",
          "K962797",
          "K914296",
          "K032866",
          "K171681",
          "K931193",
          "K161631",
          "K061545",
          "K953255",
          "K963273",
          "K023518",
          "K972509",
          "K962481",
          "K081496",
          "K251401",
          "K101768",
          "K951144",
          "K914527",
          "K190900",
          "K251671",
          "K861252",
          "K241898",
          "K090178",
          "K210001",
          "K964012",
          "K032500",
          "K012568",
          "K030870",
          "K042258",
          "K961577",
          "K130269",
          "K141074",
          "K971980",
          "K171303",
          "K071503",
          "K001888",
          "K900892",
          "K091269",
          "K023110",
          "K934722",
          "K936001",
          "K022960",
          "K223212",
          "K041955",
          "K981027",
          "K033001",
          "K003264",
          "K131233",
          "K011572",
          "K003882",
          "K041671",
          "K020300",
          "K223422",
          "K042467",
          "K123737",
          "K133657",
          "K241364",
          "K193152",
          "K931297",
          "K031825",
          "K113448",
          "K214062",
          "K964438",
          "K023932",
          "K001681",
          "K113350",
          "K922671",
          "K983516",
          "K992731",
          "K926133",
          "K173578",
          "K190457",
          "K252477",
          "K113408",
          "K920624",
          "K032036",
          "K890100",
          "K072468",
          "K970627",
          "K894056",
          "K031872",
          "K201933",
          "K033782",
          "K935318",
          "K241751",
          "K060486",
          "K926206",
          "K042935",
          "K930428",
          "K071068",
          "K873775",
          "K982300",
          "K922427",
          "K101013",
          "K913630",
          "K082244",
          "K182237",
          "K915470",
          "K082506",
          "K962738",
          "K060060",
          "K014033",
          "K113754",
          "K180514",
          "K130451",
          "K983514",
          "K980715",
          "K210418",
          "K080927",
          "K062450",
          "K940478",
          "K210173",
          "K043293",
          "K192277",
          "K982171",
          "K232569",
          "K980959",
          "K210880",
          "K981291",
          "K991129",
          "K945721",
          "K081201",
          "K923044",
          "K162736",
          "K161674",
          "K810589",
          "K952109",
          "K130902",
          "K914179",
          "K072307",
          "K942837",
          "K042257",
          "K142006",
          "K050366",
          "K231576",
          "K992335",
          "K914807",
          "K223325",
          "K182336",
          "K211846",
          "K003241",
          "K230600",
          "K932745",
          "K193241",
          "K132347",
          "K991565",
          "K013667",
          "K922313",
          "K954143",
          "K910048",
          "K211764",
          "K260524",
          "K961597",
          "K790169",
          "K933321",
          "K954874",
          "K193210",
          "K002553",
          "K222895",
          "K923151",
          "K925186",
          "K041543",
          "K923736",
          "K072191",
          "K021656",
          "K202882",
          "K001026",
          "K942116",
          "K941223",
          "K162483",
          "K193178",
          "K892875",
          "K082581",
          "K110507",
          "K914267",
          "K912176",
          "K231833",
          "K051855",
          "K080784",
          "K103710",
          "K940236",
          "K912573",
          "K131634",
          "K241585",
          "K972360",
          "K031874",
          "K922080",
          "K053062",
          "K231102",
          "K972686",
          "K160120",
          "K202392",
          "K041182",
          "K041840",
          "K173816",
          "K141652",
          "K921008",
          "K161574",
          "K944720",
          "K123646",
          "K021633",
          "K251561",
          "K122241",
          "K912177",
          "K052430",
          "K003434",
          "K962955",
          "K241665",
          "K852239",
          "K781753",
          "K241266",
          "K963730",
          "K940487",
          "K231572",
          "K153402",
          "K933372",
          "K200474",
          "K031705",
          "K040057"
        ],
        "registration_number": [
          "",
          "3007675950",
          "3026391023",
          "3011416394",
          "3029521953",
          "3038191646",
          "3018788582",
          "3021032044",
          "9613445",
          "3000126629",
          "3008355361",
          "9614698",
          "1034973",
          "9611343",
          "3014134519",
          "8022257",
          "3032577207",
          "3009136051",
          "3031503890",
          "3005128583",
          "3023003446",
          "3027338963",
          "3012761544",
          "3004993756",
          "3006209933",
          "3022742930",
          "3005877899",
          "3000976525",
          "3030210400",
          "3030982377",
          "3013679558",
          "3015232217",
          "3015425142",
          "9710645",
          "3009963139",
          "1833124",
          "3034246184",
          "3027339477",
          "2411512",
          "1424263",
          "3014343100",
          "1450662",
          "3004754211",
          "3011950073",
          "9613299",
          "3014954414",
          "3004504920",
          "3015777306",
          "3011015597",
          "3008962177",
          "1423348",
          "3014809646",
          "3036666444",
          "3026047529",
          "2134213",
          "3030186509",
          "3021059265",
          "3008007310",
          "3008632256",
          "3012690638",
          "3002808157",
          "3033524251",
          "3010398867",
          "3007545404",
          "3005945241",
          "3006611212",
          "1066019",
          "3012085143",
          "3015763655",
          "3009196578",
          "2320968",
          "3003477135",
          "3017375271",
          "3035950510",
          "2126677",
          "2031050",
          "9613936",
          "9617978",
          "3015276088",
          "8030233",
          "3016007746",
          "2247992",
          "1423253",
          "3010703925",
          "3008496839",
          "3014470527",
          "3005810333"
        ],
        "fei_number": [
          "",
          "3007675950",
          "3026391023",
          "3011416394",
          "3029521953",
          "3038191646",
          "3018788582",
          "1000284313",
          "3021032044",
          "3000126629",
          "3008355361",
          "1000514697",
          "1034973",
          "3014134519",
          "3032577207",
          "3009136051",
          "3031503890",
          "3004571294",
          "3005128583",
          "3001654007",
          "3023003446",
          "3027338963",
          "3012761544",
          "3004993756",
          "3006209933",
          "3022742930",
          "3005877899",
          "3000976525",
          "3030210400",
          "3030982377",
          "3013679558",
          "3015232217",
          "3015425142",
          "3009963139",
          "1833124",
          "3034246184",
          "3027339477",
          "2411512",
          "3014343100",
          "1450662",
          "3004754211",
          "3011950073",
          "3014954414",
          "3004504920",
          "3015777306",
          "3003318268",
          "3011015597",
          "3008962177",
          "3003015552",
          "3014809646",
          "3036666444",
          "3026047529",
          "3003079232",
          "3000210013",
          "3002175190",
          "3030186509",
          "3021059265",
          "3008007310",
          "3008632256",
          "3012690638",
          "3002808157",
          "3033524251",
          "3010398867",
          "3007545404",
          "3005945241",
          "3006611212",
          "3002808382",
          "3012085143",
          "3008581796",
          "3015763655",
          "3009196578",
          "3003477135",
          "3017375271",
          "1000208827",
          "3035950510",
          "2126677",
          "3015276088",
          "3002831423",
          "1000571342",
          "3002808139",
          "3016007746",
          "3001236767",
          "3003757840",
          "3010703925",
          "3008496839",
          "3014470527",
          "3005810333"
        ],
        "device_name": "System, Tomography, Computed, Emission",
        "medical_specialty_description": "Radiology",
        "regulation_number": "892.1200",
        "device_class": "2"
      }
    }
  ]
}