      "cfres_id": "149390",
      "product_res_number": "Z-0041-2017",
      "event_date_initiated": "2016-07-10",
      "event_date_posted": "2016-10-05",
      "recall_status": "Terminated",
      "event_date_terminated": "2017-03-02",
      "res_event_number": "75115",
      "product_code": "JEA",
      "product_description": "Stationary Column TruSystem 7599, Material Number 1717020\n\nPatient positioning during surgery, ranging from anesthesia induction to actual surgery to recover from the anesthesia. Also, patient transport on the operating table top from a patient transfer system to the operating theater of from the operating theater to a patient transfer system.",
      "code_info": "Serial Numbers - 101863421, 101863427, 101863433, 101875827, 101879148, 101879149, 101882031, 101884650, 101884651, 101884653, 101884654, 101890658, 101890659, 101895636, 101904999, 101907202, 101907203",
      "firm_fei_number": "3003184737",
      "recalling_firm": "Trumpf Medical Systems, Inc.",
      "address_1": "1046 Legrand Blvd",
      "city": "Charleston",
      "state": "SC",
      "postal_code": "29492-7672",
      "additional_info_contact": "Chandler Sprinkles\n843-329-0543",
      "reason_for_recall": "Three complaints describing TruSystem tables unexpectedly descending approximately 20 centimeters.",
      "root_cause_description": "Nonconforming Material/Component",
      "action": "Trumpf Medical sent an Urgent Field Safety Notice dated July 8, 2015, to all affected consignees. The letter indicated that the tables should not be used until an authorized service engineer has exchanged the spindles of the affected operating tables.  The letter included an acknowledgement form which is to be returned.  The letter also requested a sub-recall if the product had been further distributed.  For questions regarding this recall call 843-329-0543.",
      "product_quantity": "84 units",
      "distribution_pattern": "Worldwide Distribution - US including CA, CT, GA, IL, NC, OR, SC, VA, WI, WY, and Internationally  to Australia, Azerbaijan, Brazil, Finland, France, Germany, Hungary, Italy, Luxembourg, Norway, Poland, Russia, Slovakia,  and Switzerland",
      "openfda": {
        "registration_number": [
          "8043933",
          "9680168",
          "3012995405",
          "3010890274",
          "3013836619",
          "8010652",
          "3031563141",
          "3027847726",
          "3015223105",
          "9681642",
          "1066635",
          "2916273",
          "3011111237",
          "2221819",
          "3009760038",
          "1000351276",
          "2921578",
          "3007031002",
          "3043007473",
          "3013522950",
          "3003923584",
          "3007143268",
          "3012329926",
          "1043572"
        ],
        "fei_number": [
          "3012995405",
          "3010890274",
          "3013836619",
          "3031563141",
          "3027847726",
          "3015223105",
          "3003184737",
          "3002619595",
          "2916273",
          "3011111237",
          "1000295034",
          "2221819",
          "3009760038",
          "1000351276",
          "1000395711",
          "2921578",
          "3007031002",
          "3043007473",
          "3013522950",
          "1841",
          "3003923584",
          "3007143268",
          "3012329926",
          "1043572"
        ],
        "k_number": [
          "K873079",
          "K910736",
          "K873080",
          "K894789",
          "K900290",
          "K953071",
          "K924094",
          "K874762",
          "K911522",
          "K881060"
        ],
        "device_name": "Table, Surgical With Orthopedic Accessories, Ac-Powered",
        "medical_specialty_description": "General, Plastic Surgery",
        "regulation_number": "878.4960",
        "device_class": "1"
      }
    }
  ]
}