{
  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-11-12",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "113036",
      "product_res_number": "Z-0022-2013",
      "event_date_initiated": "2012-09-13",
      "event_date_posted": "2012-10-09",
      "recall_status": "Terminated",
      "event_date_terminated": "2013-01-29",
      "res_event_number": "63214",
      "product_code": "FLF",
      "k_numbers": [
        "K902036",
        "K941748"
      ],
      "product_description": "3M Steri-Vac Gas Sterilizer/Aerator models 5XL and 8XL.\n\n3M Steri-Vac Gas Sterilizer/Aerator is a compact unit designed to sterilize heat- and/or moisture-sensitive devices. This gas sterilizer/aerator is intended for indoor use only.",
      "code_info": "Model 5XL 1-door, serial numbers from 721799 - 722166.   Model 5XL 2-door, serial numbers from 820248 - 820285.   Model 8XL 1-door, serial numbers from 350608 - 350887.  Model 8XL 2-door, serial numbers from 450073 - 450105",
      "firm_fei_number": "2110898",
      "recalling_firm": "3M Company - Health Care Business",
      "address_1": "3M Center 2510 Conway Ave , B# 275-5-W-6 2510 3m center conway ave b# 275-5-w-6",
      "city": "Saint Paul",
      "state": "MN",
      "postal_code": "55144",
      "additional_info_contact": "3M Health Care Service Line\n800-688-5888",
      "reason_for_recall": "3M determined that the electrical grounding mechanism for the Steri-Vac 5XL and 8XL gas Sterilizer/Aerator did not meet all of the requirements of the standard in that the electrical wiring, which is insulated and contained within the sealed door should have a stronger connection to the protective electrical grounding mechansim.",
      "root_cause_description": "Component design/selection",
      "action": "3m Healthcare Service Center sent a Urgent Medical Device Field Correction letter dated September 19. 2012, to all affected customers. The letter identified the product the problem and the action needed to be taken by the customer.\n\n3M will contact you to schedule an appointment for a field correction on any unit in the range of serial numbers provided in the table. 3Ms goal is to service the affected units with minimal disruption to your facility.\n\nWe apologize for any inconvenience this field correction may cause. Please be assured that 3M is committed to the highest level of safety and customer service and we are proud of our longstanding safety record for 3M\" Steri-Vac\" Gas Sterilizers.\n\nFor Further Information If you have any questions, please contact the 3M Health Care Service Line at 1-800-688-5888 or your local 3M representative.\n\n\n.",
      "product_quantity": "707 units (61 US, 646 OUS)",
      "distribution_pattern": "Worldwide Distribution--USA (nationwide) including the states of  AL, CO, CT, GA, IN, KY, MA, MI, MN, MO, MS, NJ, OH, PA, SC, TN, VA, WA and WI., and the countries of Argentina, Barbados, Chile, China, Colombia, Costa Rica, Ecuador, Germany, India, Indonesia, Japan, Korea, Kuwait, Lebanon, Malaysia, Mexico, Morocco, Pakistan, Paraguay, Peru, Philippines, Poland, Republic of Guinea, Russia, South Africa, Taiwan, Thailand, Trinidad, UAE, Venezuela, Vietnam and  Zimbabwe.",
      "openfda": {
        "k_number": [
          "K170432",
          "K821842",
          "K090636",
          "K832945",
          "K941748",
          "K873200",
          "K023290",
          "K192978",
          "K852115",
          "K014013",
          "K902036",
          "K915682",
          "K905119",
          "K812867",
          "K792660",
          "K142034",
          "K820783",
          "K923442",
          "K020875",
          "K920930",
          "K051595",
          "K901146",
          "K910649",
          "K150646",
          "K931872",
          "K833457"
        ],
        "device_name": "Sterilizer, Ethylene-Oxide Gas",
        "medical_specialty_description": "General Hospital",
        "regulation_number": "880.6860",
        "device_class": "2",
        "registration_number": [
          "3031841433",
          "3015392401",
          "3042272797",
          "2133641",
          "3004634710",
          "3003936696",
          "3005899764",
          "2084725",
          "3005646850"
        ],
        "fei_number": [
          "3031841433",
          "3015392401",
          "3003662624",
          "3042272797",
          "3004634710",
          "3003936696",
          "3005899764",
          "3000203466",
          "3005646850"
        ]
      }
    }
  ]
}