{
  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-08-13",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "94949",
      "product_res_number": "Z-0341-2011",
      "event_date_initiated": "2010-03-29",
      "event_date_posted": "2010-11-10",
      "recall_status": "Terminated",
      "event_date_terminated": "2011-06-15",
      "res_event_number": "56751",
      "product_code": "CAC",
      "k_numbers": [
        "K960006"
      ],
      "product_description": "The box label states: \"ATF 40 Fast Start Kit 9108491...STERILE...FRESENIUS KABI...Fresenius Kabi AG 61345 Bad Hamburg Germany...Federal (USA) Law restricts this device to sale by or on order of a physician\".\n\nThe ATF 40 Fast Start Kit contains one each AT1 Autotransfusion Set, ATS Suction Line, and the ATR40 Autotransfusion Reservoir.\n\nATS is a suction line to aspirate and add anticoagulate to shed blood from the surgical field into an autotransfusion reservoir (ATR). The ATS has a  inch. suction port and is connected to a vacuum source.\n\nATR is an autotransfusion reservoir to collect, de-foam, filter, and store blood prior to processing. The ATR reservoirs are offered with either a 120 micron or a 40 micron filter.\nATF 40 Autotransfusion set is a disposable set, dedicated component of the Fresenius CATS Continuous Autotransfusion System, which in turn is an Autotransfusion device for the processing of autologous shed blood collected intraoperatively and postoperatively to obtain washed packed red blood cells for reinfusion.",
      "code_info": "Lot numbers:  YHT242, YIT012, YIT291, YKT011, YKT142, YKT283, YLT302, ZAT262, ZBT125, ZCT 032, and ZCT 295.",
      "firm_fei_number": "3007344667",
      "recalling_firm": "Fresenius Kabi, LLC",
      "address_1": "14715 Ne 95th St Ste 100 14715 Ne 95th St",
      "address_2": "Ste 100",
      "city": "Redmond",
      "state": "WA",
      "postal_code": "98052-2566",
      "additional_info_contact": "Kathryn Sivertson\n425-242-2000",
      "reason_for_recall": "Using AT1 Autotransfusion Set from specific batches in combination with the auto transfusion device CATS Continuous Autotransfusion has led to insufficient suction of shed blood from the collection reservoir.  The results in the failure message \"alarm blood flow\" and the CATS device stops in a secure mode.",
      "root_cause_description": "Other",
      "action": "Fresenius Kabi sent out a Technical Notification letter dated March 29, 2010, to one distributor located in Ann Arbor, Michigan.    The distributor sent  the technical notification with a cover letter to each of their customer's that had ordered AT1's, ATF120's and ATF40's over the last year.  The letter identified the product, the problem, and the action to be taken.  Customers were notified that the autotransfusion prime and / or washing procedure can be continued after alarm blood flow by following Alternative procedures. \n\nThe Technical Notification informs the distributor about the problem of the AT1 (item #9005101), but  also mentions the other two products ATF120 (item #9108501) and ATF40 (item #9108491) which have no known problem.\n\nThe distributor is advised to contact Fresenius Kabi, LLC for any question regarding the Technical Notification.\nFor questions regarding this recall call (425) 242-2074.",
      "product_quantity": "17, 444 units distributed in US",
      "distribution_pattern": "Worldwide Distribution - USA and the countries of Australia,Austria, Brazil, Canada, China, Denmark, France, Germany, Hong Kong, India, Italy, Japan, Malaysia, Netherlands, Phillipines, Portugal, Switzerland, Thailand, UK, and Vietnam.",
      "openfda": {
        "k_number": [
          "K955010",
          "K897127",
          "K881692",
          "K893394",
          "K862684",
          "K160197",
          "K902713",
          "K020647",
          "K942791",
          "K893218",
          "K883934",
          "K910238",
          "K963850",
          "K900299",
          "K022348",
          "K781550",
          "K892443",
          "K022167",
          "K012406",
          "K852178",
          "K896858",
          "K963758",
          "K781551",
          "K973627",
          "K884564",
          "K982755",
          "K973378",
          "K904515",
          "K953118",
          "K103202",
          "K012178",
          "K831849",
          "K231782",
          "K894294",
          "K923016",
          "K913177",
          "K883058",
          "K882757",
          "K210862",
          "K843821",
          "K902059",
          "K971274",
          "K875023",
          "K931552",
          "K872160",
          "K992723",
          "K871258",
          "K984233",
          "K881350",
          "K210176",
          "K890171",
          "K892857",
          "K160735",
          "K031554",
          "K791891",
          "K781552",
          "K993581",
          "K920273",
          "K812292",
          "K041525",
          "K912609",
          "K951592",
          "K911656",
          "K952224",
          "K180831",
          "K983022",
          "K896857",
          "K852425",
          "K904041",
          "K872927",
          "K912956",
          "K024097",
          "K912610",
          "K963098",
          "K053000",
          "K893402",
          "K881129",
          "K904888",
          "K964070",
          "K871568",
          "K842610",
          "K873807",
          "K852736",
          "K221483",
          "K913181",
          "K043127",
          "K913684",
          "K991986",
          "K193361",
          "K892819",
          "K897126",
          "K082923",
          "K933960",
          "K914053",
          "K014083",
          "K962475",
          "K901232",
          "K982650",
          "K112245",
          "K120953",
          "K942844",
          "K110782",
          "K972894",
          "K895297",
          "K101586",
          "K894668",
          "K872162",
          "K940519",
          "K970857",
          "K812355",
          "K201305",
          "K140197",
          "K970714",
          "K854301",
          "K830735",
          "K931106",
          "K960734",
          "K871847",
          "K240426",
          "K772196",
          "K122262",
          "K982660",
          "K881631",
          "K902759",
          "K140205",
          "K945775",
          "K910211",
          "K932093",
          "K933625",
          "K851024",
          "K902671",
          "K014187",
          "K915130",
          "K210089",
          "K240584",
          "K221722",
          "K883663",
          "K932890",
          "K192368",
          "K872814",
          "K120586",
          "K924894",
          "K913247",
          "K960006",
          "K904164",
          "K880162",
          "K893578",
          "K944232",
          "K901401",
          "K913773",
          "K883082",
          "K241236",
          "K926338",
          "K181954",
          "K772280",
          "K093535",
          "K881683",
          "K900325",
          "K872590",
          "K872158",
          "K881421",
          "K043140",
          "K781553",
          "K903392",
          "K802674",
          "K940678",
          "K910991",
          "K860306",
          "K936220",
          "K982241",
          "K931899",
          "K901138",
          "K022489",
          "K904474",
          "K162423",
          "K925827",
          "K912019",
          "K130043",
          "K914119",
          "K974897",
          "K904794",
          "K831557",
          "K101907",
          "K982712",
          "K900483",
          "K962689",
          "K864374",
          "K811228",
          "K060482",
          "K963759",
          "K131553",
          "K920618",
          "K884844",
          "K871624",
          "K861677"
        ],
        "registration_number": [
          "3010291427",
          "9611109",
          "2029275",
          "1064858",
          "9680425",
          "3016994551",
          "1220477",
          "1526534",
          "3007923088",
          "3031823122",
          "3005012805",
          "3004634229",
          "3044156918",
          "2011171",
          "9612051",
          "3006654680",
          "3010273872",
          "3011270181",
          "9615908",
          "3011137372",
          "3010084488",
          "3020347218",
          "8022032",
          "1724474",
          "3008810357",
          "3009380063",
          "3004142400",
          "3010041511",
          "2032112",
          "2184009",
          "3004548776",
          "9681630",
          "3011554160",
          "3015219237",
          "3010009632",
          "3011773324",
          "3010220595",
          "1219343",
          "1718850",
          "2029015",
          "2528981",
          "9680143",
          "9680841",
          "1836518",
          "3010413216",
          "3011175548",
          "3004365956",
          "9617787",
          "3019807891",
          "8043817",
          "3004593495",
          "1928237",
          "3004111573",
          "1424263",
          "9617601"
        ],
        "fei_number": [
          "3010291427",
          "3003094575",
          "3016994551",
          "3002534070",
          "1220477",
          "3003076831",
          "1526534",
          "3003015552",
          "3007923088",
          "3031823122",
          "3005426550",
          "3005012805",
          "1000160458",
          "3004634229",
          "3044156918",
          "2011171",
          "3006654680",
          "3002807308",
          "3003261020",
          "3010273872",
          "3011270181",
          "3010084488",
          "3020347218",
          "3003282181",
          "3008810357",
          "3009380063",
          "3004142400",
          "3002808845",
          "3010041511",
          "3004548776",
          "3011554160",
          "1000306431",
          "3015219237",
          "3010009632",
          "3011773324",
          "3010220595",
          "1219343",
          "1718850",
          "3007596547",
          "2528981",
          "3002808267",
          "3005747797",
          "3010413216",
          "3011175548",
          "3004365956",
          "3001717360",
          "3019807891",
          "3008397795",
          "3004593495",
          "1928237",
          "3003094851",
          "3003327833",
          "3002806457",
          "1000116158",
          "3004111573"
        ],
        "device_name": "Apparatus, Autotransfusion",
        "medical_specialty_description": "Anesthesiology",
        "regulation_number": "868.5830",
        "device_class": "2"
      }
    }
  ]
}