      "cfres_id": "91152",
      "product_res_number": "Z-0588-2011",
      "event_date_initiated": "2010-03-10",
      "event_date_posted": "2010-12-10",
      "recall_status": "Terminated",
      "event_date_terminated": "2011-08-04",
      "res_event_number": "55571",
      "product_code": "CHI",
      "k_numbers": [
        "K952816"
      ],
      "product_description": "Dimension LIP Flex Reagent Cartridge, Catalog# DF55A",
      "code_info": "Lot Number: DE0320, FC0306, GB0342, EA0334, FB0278, DA0293, GB0286, FA0355, EA0362, EB0362.",
      "firm_fei_number": "2517506",
      "recalling_firm": "Siemens Healthcare Diagnostics, Inc.",
      "address_1": "500 GBC Drive, Mailstop 514 500 GBC Drive Mailstop 514",
      "address_2": "PO BOX 6101",
      "city": "Newark",
      "state": "DE",
      "postal_code": "19714-6101",
      "additional_info_contact": "Siemens Technical Solutions Center\n800-441-9250",
      "reason_for_recall": "Open Well instability: After calibration, QC shifts high (out of range) after the Flex Well is hydrated. Shifts of up to 20% have been observed in both QC and patient samplesas soon as two hours post hydration.",
      "root_cause_description": "Other",
      "action": "Recalling firm issued \"Urgent Field Safety Notice\", dated March 2010, informing users of the problem and to transition to the revised Lipasae method.",
      "product_quantity": "21171",
      "distribution_pattern": "Nationwide Distribution throughout the US.",
      "openfda": {
        "k_number": [
          "K961179",
          "K802842",
          "K923917",
          "K874640",
          "K970905",
          "K874027",
          "K760786",
          "K900827",
          "K862312",
          "K811553",
          "K897150",
          "K952180",
          "K952647",
          "K921249",
          "K875173",
          "K952816",
          "K884596",
          "K941085",
          "K845027",
          "K920337"
        ],
        "registration_number": [
          "",
          "3012240236",
          "2247288",
          "9681753",
          "2032900",
          "2250051",
          "3007662974",
          "9610126",
          "3003539867",
          "1827821",
          "8040374",
          "2050010",
          "3005333358",
          "1220972",
          "3010825766",
          "3014325803",
          "3003741796",
          "1319681",
          "3005094123",
          "3000148879",
          "3016438761",
          "2432235",
          "8020316",
          "2517506",
          "3002809144",
          "3004493545",
          "3021841051",
          "3013660430",
          "1319809",
          "2050012"
        ],
        "fei_number": [
          "",
          "3012240236",
          "3002806809",
          "3002806559",
          "2250051",
          "3007662974",
          "3000303338",
          "1827821",
          "5864",
          "2050010",
          "3005333358",
          "1220972",
          "3010825766",
          "3014325803",
          "3003741796",
          "1000122044",
          "3004445302",
          "1000305840",
          "3005094123",
          "3000148879",
          "3006769061",
          "3016438761",
          "2432235",
          "2517506",
          "3002809144",
          "3004493545",
          "3021841051",
          "1000136573",
          "3013660430",
          "2050012"
        ],
        "device_name": "Lipase-Esterase, Enzymatic, Photometric, Lipase",
        "medical_specialty_description": "Clinical Chemistry",
        "regulation_number": "862.1465",
        "device_class": "1"
      }
    }
  ]
}