      "cfres_id": "86304",
      "product_res_number": "Z-0334-2010",
      "event_date_initiated": "2009-10-23",
      "event_date_posted": "2009-11-17",
      "recall_status": "Terminated",
      "event_date_terminated": "2010-06-09",
      "res_event_number": "53605",
      "product_code": "MSD",
      "k_numbers": [
        "K032061",
        "K040509",
        "K042858",
        "K060155",
        "K063431",
        "K063441"
      ],
      "product_description": "40CM ALTA LR GOLD STD KIT\nModel: ALC35SH40\n\nALTA GOLD\n15.5 Fr polyurethane twin lumen fixed tip heparin coated hemodialysis catheter, cuff and side holes for chronic hemodialysis and\napheresis. Kit contains catheter, 18 gauge introducer needle, 12cc syringe, J/straight 0.038 inch x 100 cm marked guidewire, 12Fr\ndilator, 14Fr dilator, 16Fr valved peel-away sheath/dilator, #11 scalpel, tunneling stylet, (4) gauze sponges, wound dressing, (2) injection sealing caps, and warning label. Latex free.",
      "code_info": "All lot codes",
      "firm_fei_number": "1000159376",
      "recalling_firm": "Spire Biomedical, Inc.",
      "address_1": "One Patriots Park",
      "city": "Bedford",
      "state": "MA",
      "postal_code": "01730-2343",
      "additional_info_contact": "Edward Rule\n617-275-6000 Ext. 274",
      "reason_for_recall": "There is a possibility that the catheter tubing could separate from the hub/bifurcation of the device. If this occurs, bleeding is the primary clinical complication likely to result from catheter tubing/hub separation. A second potential clinical complication is air embolism, particularly for the segment of the patient population that develops negative central venous pressure during normal respira",
      "root_cause_description": "Process control",
      "action": "Spire Medical issued an \"Urgent device Recall\" letter dated 10/22/09 by FEDEX to end users.  Users are requested to return product. For questions, contact Spire Biomedical Customer Service at 1-877-876-8635.",
      "product_quantity": "96 units",
      "distribution_pattern": "Worldwide distribution - Nationwide, Government. Foreign: Canada, France.",
      "openfda": {
        "k_number": [
          "K032712",
          "K021212",
          "K022662",
          "K161026",
          "K010306",
          "K030020",
          "K001633",
          "K101843",
          "K060155",
          "K211410",
          "K030277",
          "K140884",
          "K020315",
          "K030983",
          "K092597",
          "K051748",
          "K241581",
          "K182443",
          "K110936",
          "K102238",
          "K981125",
          "K111817",
          "K063441",
          "K130192",
          "K171571",
          "K060972",
          "K063431",
          "K021759",
          "K023847",
          "K072499",
          "K173667",
          "K012562",
          "K141051",
          "K062901",
          "K982326",
          "K200627",
          "K010567",
          "K111372",
          "K092205",
          "K113487",
          "K091506",
          "K111651",
          "K982333",
          "K102043",
          "K042858",
          "K040328",
          "K121933",
          "K040318",
          "K002901",
          "K130889",
          "K100169",
          "K123196",
          "K040492",
          "K143567",
          "K022905",
          "K140492",
          "K073092",
          "K123943",
          "K091760",
          "K040078",
          "K203767",
          "K994105",
          "K002902",
          "K040260",
          "K053589",
          "K060288",
          "K133796",
          "K131814",
          "K051280",
          "K080400",
          "K030502",
          "K090148",
          "K981365",
          "K040509",
          "K040736",
          "K012948",
          "K121848",
          "K011916",
          "K042016",
          "K981994",
          "K051584",
          "K971925",
          "K203575",
          "K012365",
          "K972207",
          "K202176",
          "K033676",
          "K073093",
          "K111117",
          "K171618",
          "K151967",
          "K023023",
          "K090101",
          "K173805",
          "K022678",
          "K020465",
          "K013160",
          "K043272",
          "K041006",
          "K141363",
          "K040402",
          "K111900",
          "K070572",
          "K041559",
          "K210461",
          "K040666",
          "K131260",
          "K003207",
          "K040992",
          "K042672",
          "K190527",
          "K010399",
          "K022000",
          "K062671",
          "K071202",
          "K033294",
          "K071422",
          "K043292",
          "K032061",
          "K130851",
          "K041914",
          "K202150",
          "K020936",
          "K090528"
        ],
        "registration_number": [
          "3033589330",
          "3015225571",
          "2518902",
          "1644312",
          "3030574705",
          "2030598",
          "1282497",
          "3007137787",
          "2527072",
          "1625425",
          "9680794",
          "2030624",
          "3015453963",
          "1319639",
          "9610849",
          "3006260740",
          "2528981",
          "1724474",
          "3002807314",
          "9617592",
          "3015859709",
          "2183744",
          "3004111573",
          "3004134316",
          "2020394",
          "3005987240",
          "1721504",
          "3006942602",
          "3006950086",
          "3003915875",
          "3007544634",
          "1833566",
          "3011137372",
          "3011534620",
          "1061124",
          "1722746",
          "3010882065",
          "9611665",
          "3016727301",
          "3008998256",
          "3011642792",
          "3013750125",
          "1018233",
          "3012536737",
          "3017210488",
          "3013557562",
          "3014461810",
          "3015309643",
          "3006082230",
          "3012050423",
          "3010041511",
          "3035111606",
          "3008110587",
          "3009211636",
          "1721676"
        ],
        "fei_number": [
          "3035111606",
          "3033589330",
          "3015225571",
          "2518902",
          "3002807095",
          "3030574705",
          "1282497",
          "3007137787",
          "2527072",
          "1625425",
          "1000306216",
          "3015453963",
          "1000518731",
          "3006260740",
          "2528981",
          "3002807314",
          "3015859709",
          "2183744",
          "3004111573",
          "3004134316",
          "2020394",
          "3005987240",
          "1000117748",
          "1721504",
          "3006942602",
          "3006097687",
          "3006950086",
          "3007544634",
          "3003915875",
          "3002807391",
          "3011534620",
          "3003094851",
          "3016727301",
          "1000512168",
          "3008998256",
          "1000138054",
          "3011642792",
          "3013750125",
          "1018233",
          "3012536737",
          "3017210488",
          "3013557562",
          "1000115408",
          "3014461810",
          "3015309643",
          "3006082230",
          "3012050423",
          "3010041511",
          "3000206435",
          "3003737899",
          "3005747797",
          "3008110587",
          "3009211636",
          "1721676",
          "3002468371"
        ],
        "device_name": "Catheter, Hemodialysis, Implanted",
        "medical_specialty_description": "Gastroenterology, Urology",
        "regulation_number": "876.5540",
        "device_class": "2"
      }
    }
  ]
}