{
  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-08-13",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "64651",
      "product_res_number": "Z-0215-2008",
      "event_date_initiated": "2007-07-24",
      "event_date_posted": "2007-11-16",
      "recall_status": "Terminated",
      "event_date_terminated": "2013-04-26",
      "res_event_number": "44962",
      "product_description": "Matrix MAX3 Actuator, Catalog Number : MAX30 A300545A252L0V000, SKF USA, Inc. Norristown, PA 19403",
      "code_info": "Serial number L03684171",
      "firm_fei_number": "3003668692",
      "recalling_firm": "Skf USA Inc",
      "address_1": "1111 Adams Ave",
      "city": "Norristown",
      "state": "PA",
      "postal_code": "19403-2403",
      "additional_info_contact": "Michele Dyer\n610-630-2715",
      "reason_for_recall": "Sudden failure of the actuator during lifting operation",
      "root_cause_description": "Labeling design",
      "action": "On or about 7/24/07, the firm sent an Important Safety Information letter and instructions to all known OEMs who purchase and sell SKF actuators for use in patient lifts. The letter reiterated and emphasized the importance of proper handling and maintenance for the actuator. The firm enclosed with this correspondence a proposed letter that the OEMs were asked to send to their customers, including the safety instructions and a new warning label.  The firm also is making available for OEMs, dealers and their customers new warning labels to place on all actuators in service.  The root cause of the problem is still under investigation by the recalling firm and additional instruction may follow later",
      "product_quantity": "1,298 units (Z-0215-0217-2008)",
      "distribution_pattern": "Worldwide Distribution-USA and Canada",
      "openfda": {}
    }
  ]
}