  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-08-20",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "50559",
      "product_res_number": "Z-0640-2007",
      "event_date_initiated": "2004-02-24",
      "event_date_posted": "2007-03-17",
      "recall_status": "Terminated",
      "event_date_terminated": "2007-05-01",
      "res_event_number": "37444",
      "product_code": "GIF",
      "k_numbers": [
        "K961439"
      ],
      "product_description": "CELL-DYN 4000 Diluent/Sheath Reagent, List Number 01H73-01, Distributed and Manufactured by: \nAbbott Diagnostics Division, 5440 Patrick Henry Drive, Santa Clara, CA",
      "code_info": "Lot Numbers: 10916I2, 10917I2,  10918I2,  10919I2,  10920I2,  10921I2",
      "firm_fei_number": "2919069",
      "recalling_firm": "Abbott Laboratories",
      "address_1": "5440 Patrick Henry Dr",
      "city": "Santa Clara",
      "state": "CA",
      "postal_code": "95054-1113",
      "reason_for_recall": "Incorrect Test Results-product may show a higher than expected platelet background count when used on the CELL-DYN 4000 System and report patient results that are unacceptable (out-of-range).",
      "root_cause_description": "Other",
      "action": "Recall Letter-On 2/24/04, the firm initiated the recall and its notification  explaining the reason for the recall and requesting the product be destroyed",
      "product_quantity": "9,800 units",
      "distribution_pattern": "Worldwide Distribution-USA including states of AL, AR, AZ, CA, CO, CT, DC, FL, GA, lA, IL, IN, KS, KY, LA, MA, MI, MN, MO, MS, NC, ND, NJ, NV, NY, OH, OK, OR, PA, SC, TN, TX, VA, WI, and WV. and countries of Australia, Argentina, Brazil, Hong Kong, Japan, Korea, Malaysia, Singapore.",
      "openfda": {
        "k_number": [
          "K830188",
          "K840041",
          "K833443",
          "K844782",
          "K800180",
          "K780830",
          "K840477",
          "K883989",
          "K882490",
          "K850239",
          "K841799",
          "K842068",
          "K801346",
          "K873347",
          "K833972",
          "K883990",
          "K842929",
          "K790028",
          "K881130",
          "K790442",
          "K760124",
          "K831617",
          "K851843",
          "K851320",
          "K781008",
          "K851280",
          "K812309",
          "K821683",
          "K850095",
          "K882267",
          "K840038",
          "K760129",
          "K840043",
          "K801357",
          "K822501",
          "K832116",
          "K822325",
          "K771787"
        ],
        "device_name": "Diluent, Blood Cell",
        "medical_specialty_description": "Hematology",
        "regulation_number": "864.8200",
        "device_class": "1",
        "registration_number": [
          "",
          "3043138885",
          "2432235",
          "3027645317",
          "9612316",
          "8031673",
          "2221819",
          "9610633",
          "2020726",
          "1319808",
          "9610824",
          "3005626422",
          "1064130",
          "3005529799",
          "9613959",
          "3013660430",
          "3004910133",
          "3002809144",
          "3006791549",
          "3006949423",
          "3009156722",
          "1219913",
          "3043088937",
          "3009297077",
          "3010188738",
          "3010421384",
          "3008629785",
          "1000191380",
          "3008526732",
          "3009963993",
          "3011558129",
          "1181121",
          "3002806944",
          "3017237798",
          "2013736",
          "3004016971",
          "1034569",
          "1061932",
          "1064608",
          "3002721051",
          "3008311438",
          "3016438761",
          "3004016977",
          "3009711478",
          "3004008703",
          "3007603826",
          "1419699",
          "3000148879",
          "1319681",
          "3005333358",
          "3010725882",
          "3016014873",
          "3008425728",
          "1177732",
          "2243072"
        ],
        "fei_number": [
          "",
          "3043138885",
          "3002808328",
          "2432235",
          "3027645317",
          "3002808299",
          "2221819",
          "3002806595",
          "2020726",
          "3000203293",
          "3005626422",
          "3005529799",
          "3013660430",
          "3004910133",
          "3002684533",
          "3002809144",
          "3003071743",
          "3006791549",
          "3006949423",
          "3009156722",
          "1219913",
          "3043088937",
          "3009297077",
          "3010421384",
          "3008629785",
          "1000191380",
          "3008526732",
          "3009963993",
          "3011558129",
          "1181121",
          "3002806944",
          "3017237798",
          "2013736",
          "3004016971",
          "1034569",
          "1000136573",
          "3002806693",
          "3002721051",
          "3008311438",
          "3016438761",
          "1000305841",
          "3004016977",
          "3009711478",
          "3004008703",
          "3007603826",
          "1419699",
          "3000148879",
          "2967",
          "3005333358",
          "3010725882",
          "3002808301",
          "3016014873",
          "3008425728",
          "1177732",
          "2243072"
        ]
      }
    }
  ]
}